These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

64 related articles for article (PubMed ID: 8992187)

  • 1. [Experimental findings and a new screw endoprosthesis of the hip joint].
    Sherepo KM
    Med Tekh; 1996; (5):38-41. PubMed ID: 8992187
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pedicle screw fixation strength: pullout versus insertional torque.
    Inceoglu S; Ferrara L; McLain RF
    Spine J; 2004; 4(5):513-8. PubMed ID: 15363421
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cortical bone trajectory for lumbar pedicle screws.
    Santoni BG; Hynes RA; McGilvray KC; Rodriguez-Canessa G; Lyons AS; Henson MA; Womack WJ; Puttlitz CM
    Spine J; 2009 May; 9(5):366-73. PubMed ID: 18790684
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Uncemented hip prosthesis: a new screw stem model with a review of 73 cases.
    Ricciardi L
    Ital J Orthop Traumatol; 1987 Jun; 13(2):145-57. PubMed ID: 3451913
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Experimental testing of an isolating-clutch endoprosthesis of the hip joint: the first results].
    Sherepo KM
    Med Tekh; 2001; (6):24-7. PubMed ID: 11837189
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A concept of need and construction of a hip joint prosthesis with isolation of the friction point from the tissue].
    Sherepo KM
    Med Tekh; 1996; (4):30-4. PubMed ID: 8965664
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Alternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.
    Olsson O
    Acta Orthop Scand Suppl; 2000 Oct; 295():1-31. PubMed ID: 11116961
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Experimental study of the optimization of the hip endoprosthesis].
    Engelbrecht E; Nieder E; Strickle E; Keller A
    Chirurg; 1980 Nov; 51(11):677-84. PubMed ID: 7471935
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hydroxyapatite-coating of pedicle screws improves resistance against pull-out force in the osteoporotic canine lumbar spine model: a pilot study.
    Hasegawa T; Inufusa A; Imai Y; Mikawa Y; Lim TH; An HS
    Spine J; 2005; 5(3):239-43. PubMed ID: 15863077
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength.
    Burval DJ; McLain RF; Milks R; Inceoglu S
    Spine (Phila Pa 1976); 2007 May; 32(10):1077-83. PubMed ID: 17471088
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fine thread versus coarse thread. A comparison of the maximum holding power.
    Gausepohl T; Möhring R; Pennig D; Koebke J
    Injury; 2001 Dec; 32 Suppl 4():SD1-7. PubMed ID: 11812471
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pedicle screw surface coatings improve fixation in nonfusion spinal constructs.
    Upasani VV; Farnsworth CL; Tomlinson T; Chambers RC; Tsutsui S; Slivka MA; Mahar AT; Newton PO
    Spine (Phila Pa 1976); 2009 Feb; 34(4):335-43. PubMed ID: 19182704
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Physical characteristics of polyaxial-headed pedicle screws and biomechanical comparison of load with their failure.
    Fogel GR; Reitman CA; Liu W; Esses SI
    Spine (Phila Pa 1976); 2003 Mar; 28(5):470-3. PubMed ID: 12616159
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [About the proposition of strength of animal-experimental results with hip endoprosthesis. A comparative analysis of the stress of the upper thigh of man and of four-leg (author's transl)].
    Diehl K; Harms J
    Z Orthop Ihre Grenzgeb; 1976 Feb; 114(1):17-25. PubMed ID: 1266299
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A biomechanical assessment of infra-laminar hooks as an alternative to supra-laminar hooks in thoracolumbar fixation.
    Murakami H; Tsai KJ; Attallah-Wasif ES; Yamazaki K; Shimamura T; Hutton WC
    Spine (Phila Pa 1976); 2006 Apr; 31(9):967-71. PubMed ID: 16641771
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A short plate compression screw with diagonal bolts--a biomechanical evaluation performed experimentally and by numerical computation.
    Peleg E; Mosheiff R; Liebergall M; Mattan Y
    Clin Biomech (Bristol, Avon); 2006 Nov; 21(9):963-8. PubMed ID: 16893595
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A biomechanical comparison of sacral pedicle screw salvage techniques.
    Ngu BB; Belkoff SM; Gelb DE; Ludwig SC
    Spine (Phila Pa 1976); 2006 Mar; 31(6):E166-8. PubMed ID: 16540856
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].
    Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R
    Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Does the direction of pedicle screw rotation affect the biomechanics of direct transverse plane vertebral derotation?
    Parent S; Odell T; Oka R; Mahar A; Newton P
    Spine (Phila Pa 1976); 2008 Aug; 33(18):1966-9. PubMed ID: 18708929
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of ilial screw loosening after triple pelvic osteotomy in dogs: 227 cases (1991-1999).
    Doornink MT; Nieves MA; Evans R
    J Am Vet Med Assoc; 2006 Aug; 229(4):535-41. PubMed ID: 16910852
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.