These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 8994945)

  • 1. An implantable intracardiac accelerometer for monitoring myocardial contractility. The Multicenter PEA Study Group.
    Rickards AF; Bombardini T; Corbucci G; Plicchi G
    Pacing Clin Electrophysiol; 1996 Dec; 19(12 Pt 1):2066-71. PubMed ID: 8994945
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Is local myocardial contractility related to endocardial acceleration signals detected by a transvenous pacing lead?
    Bongiorni MG; Soldati E; Arena G; Quirino G; Vernazza F; Bernasconi A; Garberoglio B
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1682-8. PubMed ID: 8945024
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detecting incipient vasovagal syncope: intraventricular acceleration.
    Brignole M; Menozzi C; Corbucci G; Garberoglio B; Plicchi G
    Pacing Clin Electrophysiol; 1997 Mar; 20(3 Pt 2):801-5. PubMed ID: 9080513
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Operator independent left ventricular function monitoring during pharmacological stress echo with the new peak transcutaneous acceleration signal.
    Bombardini T; Marcelli E; Picano E; Borghi B; Fedriga P; Garberoglio B; Gaggini G; Plicchi G
    Heart; 2001 Mar; 85(3):286-9. PubMed ID: 11179267
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Closed-loop stimulation using intracardiac impedance as a sensor principle: correlation of right ventricular dP/dtmax and intracardiac impedance during dobutamine stress test.
    Osswald S; Cron T; Grädel C; Hilti P; Lippert M; Ströbel J; Schaldach M; Buser P; Pfisterer M
    Pacing Clin Electrophysiol; 2000 Oct; 23(10 Pt 1):1502-8. PubMed ID: 11060870
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Peak endocardial acceleration reflects heart contractility also in atrial fibrillation.
    Bombardini T; Gaggini G; Marcelli E; Parlapiano M; Plicchi G
    Pacing Clin Electrophysiol; 2000 Sep; 23(9):1381-5. PubMed ID: 11025894
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of acute myocardial ischemia during percutaneous transluminal coronary angioplasty by endocardial acceleration.
    Theres HP; Kaiser DR; Nelson SD; Glos M; Leuthold T; Baumann G; Sowelam S; Sheldon TJ; Stylos L
    Pacing Clin Electrophysiol; 2004 May; 27(5):621-5. PubMed ID: 15125718
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of a new noninvasive device for the monitoring of peak endocardial acceleration in pigs: implications for optimization of pacing site and configuration.
    Bordachar P; Labrousse L; Ploux S; Thambo JB; Lafitte S; Reant P; Jais P; Haissaguerre M; Clementy J; Dos Santos P
    J Cardiovasc Electrophysiol; 2008 Jul; 19(7):725-9. PubMed ID: 18284498
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a rate adaptive pacemaker based on the maximum rate-of-rise of right ventricular pressure (RV dP/dtmax).
    Bennett T; Sharma A; Sutton R; Camm AJ; Erickson M; Beck R
    Pacing Clin Electrophysiol; 1992 Feb; 15(2):219-34. PubMed ID: 1372421
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contributions of a hemodynamic sensor embedded in an atrial lead in a porcine model.
    Bordachar P; Garrigue S; Ritter P; Ploux S; Labrousse L; Casset C; Haissaguerre M; Dos Santos P
    J Cardiovasc Electrophysiol; 2011 May; 22(5):579-83. PubMed ID: 20946232
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New cardiomechanic pacing lead sensor based on high frequency parameters: experimental studies in sheep.
    Brusich S; Tomasic D; Sovilj S; Magjarevic R; Ferek-Petric B
    J Cardiovasc Electrophysiol; 2013 Mar; 24(3):338-46. PubMed ID: 23384198
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hemodynamic assessment of right, left, and biventricular pacing by peak endocardial acceleration and echocardiography in patients with end-stage heart failure.
    Bordachar P; Garrigue S; Reuter S; Hocini M; Kobeissi A; Gaggini G; Jaïs P; Haïssaguerre M; Clementy J
    Pacing Clin Electrophysiol; 2000 Nov; 23(11 Pt 2):1726-30. PubMed ID: 11139910
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transthoracic sensor for noninvasive assessment of left ventricular contractility: validation in a minipig model of chronic heart failure.
    Gemignani V; Bianchini E; Faita F; Lionetti V; Campan M; Recchia FA; Picano E; Bombardini T
    Pacing Clin Electrophysiol; 2010 Jul; 33(7):795-803. PubMed ID: 20132499
    [TBL] [Abstract][Full Text] [Related]  

  • 14. PEA I and PEA II based implantable haemodynamic monitor: pre clinical studies in sheep.
    Plicchi G; Marcelli E; Parlapiano M; Bombardini T
    Europace; 2002 Jan; 4(1):49-54. PubMed ID: 11846317
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Load-sensitivity of regional tissue deformation in the right ventricle: isovolumic versus ejection-phase indices of contractility.
    Missant C; Rex S; Claus P; Mertens L; Wouters PF
    Heart; 2008 Apr; 94(4):e15. PubMed ID: 17686806
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Enhancement of the force-frequency effect on myocardial contractility by adrenergic stimulation in conscious dogs.
    Kambayashi M; Miura T; Oh BH; Rockman HA; Murata K; Ross J
    Circulation; 1992 Aug; 86(2):572-80. PubMed ID: 1353420
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of myocardial acceleration during isovolumic contraction as a novel noninvasive index of right ventricular contractility: comparison with ventricular pressure-volume relations in an animal model.
    Vogel M; Schmidt MR; Kristiansen SB; Cheung M; White PA; Sorensen K; Redington AN
    Circulation; 2002 Apr; 105(14):1693-9. PubMed ID: 11940549
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Can strain rate and strain quantify changes in regional systolic function during dobutamine infusion, B-blockade, and atrial pacing--implications for quantitative stress echocardiography.
    Weidemann F; Jamal F; Kowalski M; Kukulski T; D'Hooge J; Bijnens B; Hatle L; De Scheerder I; Sutherland GR
    J Am Soc Echocardiogr; 2002 May; 15(5):416-24. PubMed ID: 12019424
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A sensor-based evaluation of heart contractility in patients with head-up tilt-induced syncope.
    Deharo JC; Peyre JP; Ritter PH; Chalvidan T; Berland Y; Djiane P
    Pacing Clin Electrophysiol; 1998 Jan; 21(1 Pt 2):223-6. PubMed ID: 9474676
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validation by serial standardized testing of a new rate-responsive pacemaker sensor based on variations in myocardial contractility.
    Clémenty J; Kobeissi A; Garrigue S; Jaïs P; Le Métayer P; Haïssaguerre M
    Europace; 2001 Apr; 3(2):124-31. PubMed ID: 11333049
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.