These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 8998260)

  • 1. Comparison of esophageal, tympanic, and forehead skin temperatures in adult patients.
    Patel N; Smith CE; Pinchak AC; Hagen JF
    J Clin Anesth; 1996 Sep; 8(6):462-8. PubMed ID: 8998260
    [TBL] [Abstract][Full Text] [Related]  

  • 2. "Deep-forehead" temperature correlates well with blood temperature.
    Harioka T; Matsukawa T; Ozaki M; Nomura K; Sone T; Kakuyama M; Toda H
    Can J Anaesth; 2000 Oct; 47(10):980-3. PubMed ID: 11032273
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Usefulness of a noncontact continuous tympanic thermometer in patients undergoing cardiac surgery using an artificial heart-lung machine].
    Yamagishi A; Toyama Y; Tobise F; Ichimiya T; Iwasaki H
    Masui; 2012 Aug; 61(8):896-900. PubMed ID: 22991822
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Bladder temperature versus tympanic membrane and forehead skin temperature].
    Joost M; Guldager H
    Ugeskr Laeger; 2003 May; 165(22):2296-8. PubMed ID: 12830757
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraoperative temperature monitoring sites in infants and children and the effect of inspired gas warming on esophageal temperature.
    Bissonnette B; Sessler DI; LaFlamme P
    Anesth Analg; 1989 Aug; 69(2):192-6. PubMed ID: 2764288
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [FRONTAL, AXILLARY AND TYMPANIC TEMPERATURE MEASUREMENTS IN CHILDREN].
    Antabak A; Sisko J; Romić I; Papes D; Pasini M; Haluzan D; Bogović M; Medancić SS; Cavar S; Luetić T; Fuchs N; Andabak M; Prlić I; Curković S
    Lijec Vjesn; 2016; 138(1-2):30-3. PubMed ID: 27290811
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Novel Zero-Heat-Flux Deep Body Temperature Measurement in Lower Extremity Vascular and Cardiac Surgery.
    Mäkinen MT; Pesonen A; Jousela I; Päivärinta J; Poikajärvi S; Albäck A; Salminen US; Pesonen E
    J Cardiothorac Vasc Anesth; 2016 Aug; 30(4):973-8. PubMed ID: 27521967
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-temperature estimates by cutaneous liquid-crystal thermometers.
    Ikeda T; Sessler DI; Marder D; Xiong J
    Anesthesiology; 1997 Mar; 86(3):603-12. PubMed ID: 9066326
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Agreement between axillary, tympanic, and mid-forehead body temperature measurements in adult emergency department patients.
    Sener S; Karcioglu O; Eken C; Yaylaci S; Ozsarac M
    Eur J Emerg Med; 2012 Aug; 19(4):252-6. PubMed ID: 21945968
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thoracotomy for lung lesion does not affect the accuracy of esophageal temperature.
    Liu SK; Chiang YY; Poon KS; Wen YR; Li CY; Liu YF; Chen KB
    Acta Anaesthesiol Taiwan; 2013 Sep; 51(3):116-9. PubMed ID: 24148740
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Esophageal, tympanic, rectal, and skin temperatures in children undergoing surgery with general anesthesia.
    Eyelade OR; Orimadegun AE; Akinyemi OA; Tongo OO; Akinyinka OO
    J Perianesth Nurs; 2011 Jun; 26(3):151-9. PubMed ID: 21641530
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Measurement of tympanic temperature by infrared and thermocouple thermometry. A comparative study].
    Nathan N; Guillaume A; Feiss P
    Ann Fr Anesth Reanim; 1995; 14(4):336-9. PubMed ID: 8572389
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical accuracy of tympanic thermometer and noncontact infrared skin thermometer in pediatric practice: an alternative for axillary digital thermometer.
    Apa H; Gözmen S; Bayram N; Çatkoğlu A; Devrim F; Karaarslan U; Günay İ; Ünal N; Devrim İ
    Pediatr Emerg Care; 2013 Sep; 29(9):992-7. PubMed ID: 23974719
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inaccuracy of liquid crystal thermometry to identify core temperature trends in postoperative adults.
    Vaughan MS; Cork RC; Vaughan RW
    Anesth Analg; 1982 Mar; 61(3):284-7. PubMed ID: 7199842
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients.
    Eshraghi Y; Nasr V; Parra-Sanchez I; Van Duren A; Botham M; Santoscoy T; Sessler DI
    Anesth Analg; 2014 Sep; 119(3):543-549. PubMed ID: 25045862
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Relative accuracy and precision of two non-invasive thermometry systems].
    Harioka T; Sone T; Nomura K; Kakuyama M
    Masui; 1993 Jun; 42(6):856-61. PubMed ID: 8320803
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Usefulness of an earphone-type infrared tympanic thermometer for intraoperative core temperature monitoring].
    Hayase T; Yamakage M; Kiya T; Satoh J; Namiki A
    Masui; 2007 Apr; 56(4):459-63. PubMed ID: 17441460
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tympanic temperature measurements: are they reliable in the critically ill? A clinical study of measures of agreement.
    Moran JL; Peter JV; Solomon PJ; Grealy B; Smith T; Ashforth W; Wake M; Peake SL; Peisach AR
    Crit Care Med; 2007 Jan; 35(1):155-64. PubMed ID: 17095941
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Axillary, tympanic, and esophageal temperature measurement: descriptive comparisons in postanesthesia patients.
    Summers S
    J Post Anesth Nurs; 1991 Dec; 6(6):420-5. PubMed ID: 1836232
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A prospective observational study testing liquid crystal phase change type thermometer placed on skin against oesophageal/pharyngeal placed thermometers in participants undergoing general anesthesia.
    Simpson G; Rodseth RN
    BMC Anesthesiol; 2019 Nov; 19(1):206. PubMed ID: 31706272
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.