  • 41. A comparative study in patients with Omnicarbon and Björk-Shiley heart valve replacement.
    Otaki M
    Int Surg; 1993; 78(4):338-42. PubMed ID: 8175264
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [Detection of Björk-Shiley prosthetic valve malfunction using intraoperative epicardial echocardiography].
    Tanaka M; Abe T; Murase M; Takeuchi E; Hibi N
    Nihon Kyobu Geka Gakkai Zasshi; 1988 Apr; 36(4):541-5. PubMed ID: 3418184
    [No Abstract]   [Full Text] [Related]  

  • 43. Echocardiographic diagnosis of a stuck Bjork-Shiley aortic valve prosthesis.
    Srivastava TN; Hussain M; Gray LA; Flowers NC
    Chest; 1976 Jul; 70(1):94-8. PubMed ID: 1277943
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [Hemolysis in patients with heart valve prostheses. Comparison between Björk-Shiley and Saint-Jude Medical valves].
    Ferrière M; Saussine M; Delpech S; Dinal D; Nègre G; Coulon P; Blanchet P; Latour H
    Arch Mal Coeur Vaiss; 1985 Aug; 78(8):1243-8. PubMed ID: 3935084
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [Echocardiographic study of perivalvular leakage of the Björk-Shiley prosthetic heart valve in the mitral position (author's transl)].
    Aida H; Yamaguchi S; Sakamoto S; Nakajima M; Iwanami H; Tadakuma O
    Nihon Kyobu Geka Gakkai Zasshi; 1980 Mar; 28(3):393-8. PubMed ID: 7381260
    [No Abstract]   [Full Text] [Related]  

  • 46. Comparative clinical results with Omniscience (STM1), Medtronic-Hall, and Björk-Shiley convexo-concave (70 degrees) prostheses in mitral valve replacement.
    Cortina JM; Martinell J; Artiz V; Fraile J; Rábago G
    J Thorac Cardiovasc Surg; 1986 Feb; 91(2):174-83. PubMed ID: 3945084
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Clinical significance of the click intervals for the diagnosis of dysfunction of the Medtronic-Hall prosthetic valve].
    Tabata T; Fukuda N; Iuchi A; Fujimoto T; Kiyoshige K; Fukuda K; Manabe K; Oki T
    J Cardiol Suppl; 1992; 28():117-28; discussion 129-31. PubMed ID: 1418871
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Mitral valve replacement with the Björk-Shiley monostrut prosthesis: a 4-year clinical experience].
    Alajmo F; Perna AM; Calamai G; Nigro R; Cassai M; Montesi G; Braconi L; Borgioli A; Preziuso M; Palminiello A
    G Ital Cardiol; 1990 Jan; 20(1):44-9. PubMed ID: 2328857
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Successful treatment of a recently thrombosed Bjork-Shiley mitral prosthesis with streptokinase--case report.
    Kumar V; Gupta BK; Narayanan PS
    Int J Cardiol; 1987 Mar; 14(3):358-62. PubMed ID: 3557714
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Echocardiographic diagnosis of a left atrial thrombus in a patient with normal prosthetic mitral valve.
    Sundar AS; Radhakrishnan S; Shrivastava S
    Int J Cardiol; 1989 May; 23(2):273-4. PubMed ID: 2722298
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Diagnostic role of intraoperative epicardial echocardiography following complications of mitral valve replacement with the Björk-Shiley prosthetic valve.
    Tanaka M; Takeuchi E; Kawamura M; Abe T
    Am J Cardiol; 1989 Dec; 64(19):1402-4. PubMed ID: 2589215
    [No Abstract]   [Full Text] [Related]  

  • 52. [Sound spectrographic studies in the diagnosis of dysfunctions of mechanical heart valve prostheses (Björk-Shiley prostheses)].
    Ebner E; Sehner J; Eger H; Ursinus W
    Z Kardiol; 1983 Mar; 72(3):174-9. PubMed ID: 6858296
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Malfunction of mitral Björk-Shiley prosthetic valve due to septal interference.
    Jackson GM; Wolf PL; Bloor CM
    Am Heart J; 1982 Jul; 104(1):158-9. PubMed ID: 7090973
    [No Abstract]   [Full Text] [Related]  

  • 54. Echocardiographic and phonocardiographic confirmation of suspected caged mitral valve malfunction.
    Berndt TB; Goodman DJ; Popp RL
    Chest; 1976 Aug; 70(2):221-30. PubMed ID: 947687
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Late results of valve replacement with the Björk-Shiley valve (1973 to 1982).
    Orszulak TA; Schaff HV; DeSmet JM; Danielson GK; Pluth JR; Puga FJ
    J Thorac Cardiovasc Surg; 1993 Feb; 105(2):302-12. PubMed ID: 8429659
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Paravalvular fistula in mitral valve implant. Intimation of malfunction of implant and quantification of regurgitant flow from effective area measurements.
    Høie J; Holen J
    Scand J Thorac Cardiovasc Surg; 1979; 13(2):103-5. PubMed ID: 472667
    [TBL] [Abstract][Full Text] [Related]  

  • 57. First-degree atrioventricular block: a cause of false malfunction of a mitral disc-valve prosthesis. Case report.
    Stefadouros MA; Smith WS; Fraser RC; Hitch W; Rubin JW
    J Thorac Cardiovasc Surg; 1975 May; 69(5):776-80. PubMed ID: 1127976
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Current status of the Beall, Bjork-Shiley, Braunwald-Cutter, Lillehei-Kaster and Smeloff-Cutter cardiac valve prostheses.
    Brawley RK; Donahoo JS; Gott VL
    Am J Cardiol; 1975 Jun; 35(6):855-65. PubMed ID: 124127
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Fracture and embolization of a Björk-Shiley disc. Fatal failure of a prosthetic mitral valve.
    Norenberg DD; Evans RW; Gundersen AE; Abellera RM
    J Thorac Cardiovasc Surg; 1977 Dec; 74(6):925-7. PubMed ID: 303729
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Two-dimensional echocardiographic assessment of complications involving the Ionescu-Shiley pericardial valve in the mitral position.
    Solana LG; Pechacek LW; DeCastro CM; Klima T; Cooley DA
    J Am Coll Cardiol; 1984 Feb; 3(2 Pt 1):328-33. PubMed ID: 6693621
    [TBL] [Abstract][Full Text] [Related]  