These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 9005579)

  • 1. [Analysis of implantation-induced nail deformation and roentgen morphometric studies as the principle for an aiming device for distal interlocking nailing without roentgen image intensification].
    Krettek C; Könemann B; Mannss J; Schandelmaier P; Schmidt U; Tscherne H
    Unfallchirurg; 1996 Sep; 99(9):671-8. PubMed ID: 9005579
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Development and initial clinical use of an aiming device for distal boring in interlocking nailing without roentgen image intensifier for the unreamed tibial nail].
    Krettek C; Könemann B; Nöschel F; Schandelmaier P; Blauth M; Tscherne H
    Unfallchirurg; 1996 Nov; 99(11):845-54. PubMed ID: 9036551
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The deformation of small diameter solid tibial nails with unreamed intramedullary insertion.
    Krettek C; Mannss J; Könemann B; Miclau T; Schandelmaier P; Tscherne H
    J Biomech; 1997 Apr; 30(4):391-4. PubMed ID: 9075008
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro and in vivo radiomorphometric analyses of distal screw hole position of the solid tibial nail following insertion.
    Krettek C; Könemann B; Miclau T; Schlandelmaier P; Blauth M; Tscherne H
    Clin Biomech (Bristol); 1997 Apr; 12(3):198-200. PubMed ID: 11415695
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [A new roentgen ray-free aiming technique for distal locking screw boring of the unreamed tibial nail].
    Krettek C; Könemann B; Farouk O; Kromm A; Tscherne H
    Langenbecks Arch Chir Suppl Kongressbd; 1996; 113():947-50. PubMed ID: 9102034
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
    Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Deformation of femoral nails with intramedullary insertion.
    Krettek C; Mannss J; Miclau T; Schandelmaier P; Linnemann I; Tscherne H
    J Orthop Res; 1998 Sep; 16(5):572-5. PubMed ID: 9820280
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A New Technique for Placement of Blocking Screws and its Mechanical Effect on Stability of Tibia Fractures with Distal Fragments after Insertion of Small-Diameter Intramedullary Nails.
    Zhang CM; Sun L; Wang Q; Huang Q; Lin H; Duan N; Zhang CC; Ma T; Xue HZ; Zhang K; Li Z
    Orthop Surg; 2021 Oct; 13(7):2127-2136. PubMed ID: 34596359
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
    Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
    J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intramedullary nailing for tibial shaft fractures in adults.
    Duan X; Al-Qwbani M; Zeng Y; Zhang W; Xiang Z
    Cochrane Database Syst Rev; 2012 Jan; 1():CD008241. PubMed ID: 22258982
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Are there any advantages in using a distal aiming device for tibial nailing? Comparing the Centro Nailing System with the Unreamed Tibia Nail.
    Veen EJ; Ettema HB; Zuurmond RG; Mostert AK
    Injury; 2011 Oct; 42(10):1049-52. PubMed ID: 21549378
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The mechanical effect of blocking screws ("Poller screws") in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails.
    Krettek C; Miclau T; Schandelmaier P; Stephan C; Möhlmann U; Tscherne H
    J Orthop Trauma; 1999 Nov; 13(8):550-3. PubMed ID: 10714781
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical study of nine different tibia locking nails.
    Schandelmaier P; Krettek C; Tscherne H
    J Orthop Trauma; 1996; 10(1):37-44. PubMed ID: 8926553
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Elastic intramedullary nailing of the tibia with the Marchetti-Vicenzi nail. 43 treated cases].
    Benmansour MB; Gottin M; Rouvillain JL; Larosa G; Dib C; Dintimille H; Catonné Y
    Rev Chir Orthop Reparatrice Appar Mot; 1999 Jun; 85(3):267-76. PubMed ID: 10422132
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influences of some design parameters on the biomechanics of the unreamed tibial intramedullary nail.
    Henley MB; Meier M; Tencer AF
    J Orthop Trauma; 1993; 7(4):311-9. PubMed ID: 8377039
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Interlocking intramedullary nailing. A solid aiming device for distal locking].
    Soyka P; Bussard C
    Helv Chir Acta; 1990 Jun; 57(1):117-20. PubMed ID: 2228668
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modified tibial nails for treating distal tibia fractures.
    Gorczyca JT; McKale J; Pugh K; Pienkowski D
    J Orthop Trauma; 2002 Jan; 16(1):18-22. PubMed ID: 11782627
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Micromotion at the fracture site after tibial nailing with four unreamed small-diameter nails--a biomechanical study using a distal tibia fracture model.
    Schüller M; Weninger P; Tschegg E; Jamek M; Redl H; Stanzl-Tschegg S
    J Trauma; 2009 May; 66(5):1391-7. PubMed ID: 19430244
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Insertion of distal screws in interlocking nailing using a new free-hand control device].
    Pennig D; Brug E
    Unfallchirurg; 1989 Jul; 92(7):331-4. PubMed ID: 2762819
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.