These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 9016651)

  • 21. Automated, solid-phase sequencing of DRB region genes using T7 sequencing chemistry and dye-labeled primers.
    McGinnis MD; Conrad MP; Bouwens AG; Tilanus MG; Kronick MN
    Tissue Antigens; 1995 Sep; 46(3 ( Pt 1)):173-9. PubMed ID: 8525476
    [No Abstract]   [Full Text] [Related]  

  • 22. High-quality automated DNA sequencing primed with hexamer strings.
    Lodhi MA; McCombie WR
    Genome Res; 1996 Jan; 6(1):10-8. PubMed ID: 8681134
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fluorescent dye-primer cycle sequencing using unpurified PCR products as templates; development of a protocol amenable to high-throughput DNA sequencing.
    Trower MK; Burt D; Purvis IJ; Dykes CW; Christodoulou C
    Nucleic Acids Res; 1995 Jun; 23(12):2348-9. PubMed ID: 7610069
    [No Abstract]   [Full Text] [Related]  

  • 24. Cassette labeling for facile construction of energy transfer fluorescent primers.
    Ju J; Glazer AN; Mathies RA
    Nucleic Acids Res; 1996 Mar; 24(6):1144-8. PubMed ID: 8604350
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Identification of the DNA bases of a DNase I footprint by the use of dye primer sequencing on an automated capillary DNA analysis instrument.
    Zianni M; Tessanne K; Merighi M; Laguna R; Tabita FR
    J Biomol Tech; 2006 Apr; 17(2):103-13. PubMed ID: 16741237
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Fluorescently labeled oligonucleotide extension: a rapid and quantitative protocol for primer extension.
    Fekete RA; Miller MJ; Chattoraj DK
    Biotechniques; 2003 Jul; 35(1):90-4, 97-8. PubMed ID: 12866410
    [TBL] [Abstract][Full Text] [Related]  

  • 27. FluoMEP: a new genotyping method combining the advantages of randomly amplified polymorphic DNA and amplified fragment length polymorphism.
    Chang A; Liew WC; Chuah A; Lim Z; Lin Q; Orban L
    Electrophoresis; 2007 Feb; 28(4):525-34. PubMed ID: 17304486
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Multi-facility survey of oligonucleotide synthesis and an examination of the performance of unpurified primers in automated DNA sequencing.
    Pon RT; Buck GA; Hager KM; Naeve CW; Niece RL; Robertson M; Smith AJ
    Biotechniques; 1996 Oct; 21(4):680-5. PubMed ID: 8891221
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Site-specific fluorescent labeling of DNA using Staudinger ligation.
    Wang CC; Seo TS; Li Z; Ruparel H; Ju J
    Bioconjug Chem; 2003; 14(3):697-701. PubMed ID: 12757398
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Sequencing multimegabase-template DNA with BigDye terminator chemistry.
    Heiner CR; Hunkapiller KL; Chen SM; Glass JI; Chen EY
    Genome Res; 1998 May; 8(5):557-61. PubMed ID: 9582199
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A new method of synthesis of fluorescently labelled oligonucleotides and their application in DNA sequencing.
    Markiewicz WT; Gröger G; Rösch R; Zebrowska A; Markiewicz M; Klotz M; Hinz M; Godzina P; Seliger H
    Nucleic Acids Res; 1997 Sep; 25(18):3672-80. PubMed ID: 9278489
    [TBL] [Abstract][Full Text] [Related]  

  • 32. DNA sequencing by capillary electrophoresis using short oligonucleotide primer libraries.
    Ruiz-Martinez MC; Carrilho E; Berka J; Kieleczawa J; Miller AW; Foret F; Carson S; Karger BL
    Biotechniques; 1996 Jun; 20(6):1058-64, 1066-9. PubMed ID: 8780876
    [TBL] [Abstract][Full Text] [Related]  

  • 33. On the mechanism of the modular primer effect.
    Beskin AD; Zevin-Sonkin D; Sobolev IA; Ulanovsky LE
    Nucleic Acids Res; 1995 Aug; 23(15):2881-5. PubMed ID: 7659510
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Heterozygote and mutation detection by direct automated fluorescent DNA sequencing using a mutant Taq DNA polymerase.
    Chadwick RB; Conrad MP; McGinnis MD; Johnston-Dow L; Spurgeon SL; Kronick MN
    Biotechniques; 1996 Apr; 20(4):676-83. PubMed ID: 8800689
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Co-operativity of hexamer ligation.
    Kaczorowski T; Szybalski W
    Gene; 1996 Nov; 179(1):189-93. PubMed ID: 8955646
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Ligation of hexamers on hexamer templates to produce primers for cycle sequencing or the polymerase chain reaction.
    Dunn JJ; Butler-Loffredo LL; Studier FW
    Anal Biochem; 1995 Jun; 228(1):91-100. PubMed ID: 8572293
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Sequencing reactions for ALF (EMBL) automated DNA sequencer. European Molecular Biology Laboratory.
    Ansorge W; Zimmermann J; Erfle H; Hewitt N; Rupp T; Schwager C; Sproat B; Stegemann J; Voss H
    Methods Mol Biol; 1993; 23():317-56. PubMed ID: 8220764
    [No Abstract]   [Full Text] [Related]  

  • 38. Generation of minisatellite variant repeat codes on an automated DNA sequencer using fluorescent dye-labeled primers.
    McKeown BJ; Lyndon GJ; Andersen JF
    Biotechniques; 1994 Nov; 17(5):901-8. PubMed ID: 7840971
    [TBL] [Abstract][Full Text] [Related]  

  • 39. DNA sequencing by the dideoxy method.
    Slatko BE; Albright LM; Tabor S; Ju J
    Curr Protoc Mol Biol; 2001 May; Chapter 7():Unit7.4A. PubMed ID: 18265267
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Energy transfer cassettes for facile labeling of sequencing and PCR primers.
    Berti L; Xie J; Medintz IL; Glazer AN; Mathies RA
    Anal Biochem; 2001 May; 292(2):188-97. PubMed ID: 11355850
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.