370 related articles for article (PubMed ID: 9017174)
21. Accuracies of seven different apex locators under various conditions.
Kang JA; Kim SK
Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2008 Oct; 106(4):e57-62. PubMed ID: 18602306
[TBL] [Abstract][Full Text] [Related]
22. Clinical evaluation of the measuring accuracy of ROOT ZX in primary teeth.
Kielbassa AM; Muller U; Munz I; Monting JS
Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2003 Jan; 95(1):94-100. PubMed ID: 12539034
[TBL] [Abstract][Full Text] [Related]
23. Accuracy of electronic apex locators in comparison to actual length--an in vivo study.
Haffner C; Folwaczny M; Galler K; Hickel R
J Dent; 2005 Sep; 33(8):619-25. PubMed ID: 16139692
[TBL] [Abstract][Full Text] [Related]
24. The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator.
Meares WA; Steiman HR
J Endod; 2002 Aug; 28(8):595-8. PubMed ID: 12184422
[TBL] [Abstract][Full Text] [Related]
25. An in vivo evaluation of Root ZX electronic apex locator.
Shabahang S; Goon WW; Gluskin AH
J Endod; 1996 Nov; 22(11):616-8. PubMed ID: 9198419
[TBL] [Abstract][Full Text] [Related]
26. An in vitro evaluation of performance of two electronic root canal length measurement devices during retreatment of different obturating materials.
Aggarwal V; Singla M; Kabi D
J Endod; 2010 Sep; 36(9):1526-30. PubMed ID: 20728721
[TBL] [Abstract][Full Text] [Related]
27. Comparison of the reliability of "0.5" and "APEX" mark measurements in two frequency-based electronic apex locators.
Jung IY; Yoon BH; Lee SJ; Lee SJ
J Endod; 2011 Jan; 37(1):49-52. PubMed ID: 21146076
[TBL] [Abstract][Full Text] [Related]
28. The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files.
Thomas AS; Hartwell GR; Moon PC
J Endod; 2003 Oct; 29(10):662-3. PubMed ID: 14606791
[No Abstract] [Full Text] [Related]
29. In vivo accuracy of three electronic root canal length measurement devices: Dentaport ZX, Raypex 5 and ProPex II.
Somma F; Castagnola R; Lajolo C; Paternò Holtzman L; Marigo L
Int Endod J; 2012 Jun; 45(6):552-6. PubMed ID: 22257341
[TBL] [Abstract][Full Text] [Related]
30. An in vivo comparison of the Root ZX II, the Apex NRG XFR, and Mini Apex Locator by using rotary nickel-titanium files.
Siu C; Marshall JG; Baumgartner JC
J Endod; 2009 Jul; 35(7):962-5. PubMed ID: 19567315
[TBL] [Abstract][Full Text] [Related]
31. Accuracy of electronic apex locater-controlled handpieces.
Barthelemy J; Gregor L; Krejci I; Wataha J; Bouillaguet S
Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Mar; 107(3):437-41. PubMed ID: 19168373
[TBL] [Abstract][Full Text] [Related]
32. Ex vivo accuracy of three electronic apex locators: Root ZX, Elements Diagnostic Unit and Apex Locator and ProPex.
Plotino G; Grande NM; Brigante L; Lesti B; Somma F
Int Endod J; 2006 May; 39(5):408-14. PubMed ID: 16640641
[TBL] [Abstract][Full Text] [Related]
33. Ex vivo evaluation of the accuracy and coefficient of repeatability of three electronic apex locators using a simple mounting model: a preliminary report.
D'Assunção FL; Albuquerque DS; Salazar-Silva JR; Dos Santos VC; Sousa JC
Int Endod J; 2010 Apr; 43(4):269-74. PubMed ID: 20487445
[TBL] [Abstract][Full Text] [Related]
34. The ability of two apex locators to locate the apical foramen: an in vitro study.
D'Assunção FL; de Albuquerque DS; de Queiroz Ferreira LC
J Endod; 2006 Jun; 32(6):560-2. PubMed ID: 16728251
[TBL] [Abstract][Full Text] [Related]
35. Accuracy of two root canal length measurement devices integrated into rotary endodontic motors when removing gutta-percha from root-filled teeth.
Uzun O; Topuz O; Tinaz C; Nekoofar MH; Dummer PM
Int Endod J; 2008 Sep; 41(9):725-32. PubMed ID: 18637852
[TBL] [Abstract][Full Text] [Related]
36. Electronic determination of root canal working length in primary molar teeth: an in vivo and ex vivo study.
Beltrame AP; Triches TC; Sartori N; Bolan M
Int Endod J; 2011 May; 44(5):402-6. PubMed ID: 21219365
[TBL] [Abstract][Full Text] [Related]
37. Electronic apex locators.
Gordon MP; Chandler NP
Int Endod J; 2004 Jul; 37(7):425-37. PubMed ID: 15189431
[TBL] [Abstract][Full Text] [Related]
38. In vitro evaluation of the accuracy of five different electronic apex locators for determining the working length of endodontically retreated teeth.
Ebrahim AK; Wadachi R; Suda H
Aust Endod J; 2007 Apr; 33(1):7-12. PubMed ID: 17461834
[TBL] [Abstract][Full Text] [Related]
39. Influence of tooth length on the accuracy of the Root ZX electronic apical foramen locator: an ex vivo study.
Saatchi M; Rahimi I; Khademi A; Farhad AR; Nekoofar MH; Dummer PM
Acta Odontol Scand; 2015 Feb; 73(2):101-6. PubMed ID: 25299599
[TBL] [Abstract][Full Text] [Related]
40. An in vitro comparison of two modern apex locators.
Weiger R; John C; Geigle H; Löst C
J Endod; 1999 Nov; 25(11):765-8. PubMed ID: 10726548
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]