BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 9019479)

  • 1. Migration of metal and polyethylene particles from articular prostheses may generate lymphadenopathy with histiocytosis.
    Baslé MF; Bertrand G; Guyetant S; Chappard D; Lesourd M
    J Biomed Mater Res; 1996 Feb; 30(2):157-63. PubMed ID: 9019479
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement.
    Urban RM; Jacobs JJ; Tomlinson MJ; Gavrilovic J; Black J; Peoc'h M
    J Bone Joint Surg Am; 2000 Apr; 82(4):457-76. PubMed ID: 10761937
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sinus histiocytosis of pelvic lymph nodes after hip replacement. A histiocytic proliferation induced by cobalt-chromium and titanium.
    Albores-Saavedra J; Vuitch F; Delgado R; Wiley E; Hagler H
    Am J Surg Pathol; 1994 Jan; 18(1):83-90. PubMed ID: 8279630
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Postarthroplasty histiocytic lymphadenopathy in gynecologic oncology patients. A benign reactive process that clinically may be mistaken for cancer.
    Zaloudek C; Treseler PA; Powell CB
    Cancer; 1996 Aug; 78(4):834-44. PubMed ID: 8756379
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Histiocytic lymphadenitis associated with a large joint prosthesis.
    O'Connell JX; Rosenberg AE
    Am J Clin Pathol; 1993 Mar; 99(3):314-6. PubMed ID: 8447293
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of lymph nodes for polyethylene particles in patients who have had a primary joint replacement.
    Shea KG; Bloebaum RD; Avent JM; Birk T; Samuelson KA
    J Bone Joint Surg Am; 1996 Apr; 78(4):497-504. PubMed ID: 8609128
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Changes seen in lymph nodes draining the sites of large joint prostheses.
    Gray MH; Talbert ML; Talbert WM; Bansal M; Hsu A
    Am J Surg Pathol; 1989 Dec; 13(12):1050-6. PubMed ID: 2596617
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lymphadenopathy associated with total joint prostheses. A report of two cases and a review of the literature.
    Benz EB; Sherburne B; Hayek JE; Falchuk KH; Sledge CB; Spector M
    J Bone Joint Surg Am; 1996 Apr; 78(4):588-93. PubMed ID: 8609139
    [No Abstract]   [Full Text] [Related]  

  • 9. Granular histiocytosis of pelvic lymph nodes following total hip arthroplasty. The presence of wear debris, cytokine production, and immunologically activated macrophages.
    Hicks DG; Judkins AR; Sickel JZ; Rosier RN; Puzas JE; O'Keefe RJ
    J Bone Joint Surg Am; 1996 Apr; 78(4):482-96. PubMed ID: 8609127
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Chromium-induced lymph node histiocytic proliferation after hip replacement. A case report.
    Munichor M; Cohen H; Volpin G; Kerner H; Iancu TC
    Acta Cytol; 2003; 47(2):270-4. PubMed ID: 12685200
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris.
    Bobyn JD; Jacobs JJ; Tanzer M; Urban RM; Aribindi R; Sumner DR; Turner TM; Brooks CE
    Clin Orthop Relat Res; 1995 Feb; (311):21-39. PubMed ID: 7634577
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative investigations of regional lymph nodes and pseudocapsules after implantation of joint endoprostheses.
    Bos I; Johannisson R; Löhrs U; Lindner B; Seydel U
    Pathol Res Pract; 1990 Dec; 186(6):707-16. PubMed ID: 2084636
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison and quantitation of wear debris of failed total hip and total knee arthroplasty.
    Hirakawa K; Bauer TW; Stulberg BN; Wilde AH
    J Biomed Mater Res; 1996 Jun; 31(2):257-63. PubMed ID: 8731215
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Identification and distribution of synthetic ligament wear particles in sheep.
    Margevicius KJ; Claes LE; Dürselen L; Hanselmann K
    J Biomed Mater Res; 1996 Jul; 31(3):319-28. PubMed ID: 8806057
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Foreign body reactions in lymph nodes of oncology patients with joint prostheses--light-, electron microscopic and immunohistological investigations.
    Bos I; Johannisson R
    Pathol Res Pract; 2004; 200(3):189-96. PubMed ID: 15200270
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tissue response in relation to type of wear particles around failed hip arthroplasties.
    Howie DW
    J Arthroplasty; 1990 Dec; 5(4):337-48. PubMed ID: 2290090
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Migration of polyethylene wear debris in hip arthroplasties: a canine model.
    Kraemer WJ; Maistrelli GL; Fornasier V; Binnington A; Zhao JF
    J Appl Biomater; 1995; 6(4):225-30. PubMed ID: 8589506
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Morphological studies in tissues surrounding alloarthroplastic joints.
    Heilmann K; Diezel PB; Rossner JA; Brinkman KA
    Virchows Arch A Pathol Anat Histol; 1975; 366(2):93-106. PubMed ID: 124105
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Side-effects of prosthetic materials on the human body.
    Uchida S; Yoshino S; Doi M; Kudo H
    Int Orthop; 1980; 3(4):285-91. PubMed ID: 7399768
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Isolation and characterization of debris in membranes around total joint prostheses.
    Schmalzried TP; Campbell P
    J Bone Joint Surg Am; 1995 Oct; 77(10):1625-6. PubMed ID: 7593071
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]