BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 9020435)

  • 1. Recurrent rotational deformity of the femur after static locking of intramedullary nails: case reports.
    Krettek C; Miclau T; Blauth M; Lindsey RW; Donow C; Tscherne H
    J Bone Joint Surg Br; 1997 Jan; 79(1):4-8. PubMed ID: 9020435
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Recurrent rotational deformity of the femur after static locking of intramedullary nails.
    Melamed EA; Zinman C
    J Bone Joint Surg Br; 1997 Nov; 79(6):1039. PubMed ID: 9393930
    [No Abstract]   [Full Text] [Related]  

  • 3. The treatment of femoral shaft fractures using intramedullary interlocked nails with and without intramedullary reaming: a preliminary report.
    Tornetta P; Tiburzi D
    J Orthop Trauma; 1997; 11(2):89-92. PubMed ID: 9057141
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of inherent anteversion of an intramedullary nail to avoid malrotation in femur fractures.
    Espinoza C; Sathy AK; Moore DS; Starr AJ; Reinert CM
    J Orthop Trauma; 2014 Feb; 28(2):e34-8. PubMed ID: 23689227
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rotational malalignment after intramedullary nailing of femoral fractures.
    Jaarsma RL; Pakvis DF; Verdonschot N; Biert J; van Kampen A
    J Orthop Trauma; 2004 Aug; 18(7):403-9. PubMed ID: 15289684
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intramedullary pressure and bone marrow fat extravasation in reamed and unreamed femoral nailing.
    Kröpfl A; Davies J; Berger U; Hertz H; Schlag G
    J Orthop Res; 1999 Mar; 17(2):261-8. PubMed ID: 10221844
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Slotted versus non-slotted locked intramedullary nailing for femoral shaft fractures.
    Alho A; Moen O; Husby T; Rønningen H; Skjeldal S
    Arch Orthop Trauma Surg; 1992; 111(2):91-5. PubMed ID: 1562431
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures.
    Vallier HA; Cureton BA; Patterson BM
    J Orthop Trauma; 2011 Dec; 25(12):736-41. PubMed ID: 21904230
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Antegrade intramedullary nailing of pediatric femoral fractures using an interlocking pediatric femoral nail and a lateral trochanteric entry point.
    Keeler KA; Dart B; Luhmann SJ; Schoenecker PL; Ortman MR; Dobbs MB; Gordon JE
    J Pediatr Orthop; 2009 Jun; 29(4):345-51. PubMed ID: 19461375
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anterograde femoral nailing with a reamed interlocking titanium alloy nail.
    Debrauwer S; Hendrix K; Verdonk R
    Acta Orthop Belg; 2000 Dec; 66(5):484-9. PubMed ID: 11196373
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Borderline indications for locked intramedullary nailing of femur and tibia].
    Vécsei V; Seitz H; Greitbauer M; Heinz T
    Orthopade; 1996 Jun; 25(3):234-46. PubMed ID: 8766662
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Post-traumatic torsional differences and functional tests following antegrade or retrograde intramedullary nailing of the distal femoral diaphysis].
    Maier DG; Reisig R; Keppler P; Kinzl L; Gebhard F
    Unfallchirurg; 2005 Feb; 108(2):109-17. PubMed ID: 15459809
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The impact of antegrade intramedullary nailing start site using the SIGN nail in proximal femoral fractures: A prospective cohort study.
    Mustafa Diab M; Wu HH; Eliezer E; Haonga B; Morshed S; Shearer DW
    Injury; 2018 Feb; 49(2):323-327. PubMed ID: 29162265
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison study between reamed and unreamed nailing of closed femoral fractures.
    Selvakumar K; Saw KY; Fathima M
    Med J Malaysia; 2001 Dec; 56 Suppl D():24-8. PubMed ID: 14569762
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ilizarov correction of malrotated femoral shaft fracture initially treated with an intramedullary nail: a case report.
    Brinker MR; Gugenheim JJ; O'Connor DP; London JC
    Am J Orthop (Belle Mead NJ); 2004 Oct; 33(10):489-93. PubMed ID: 15540848
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intramedullary nailing of femoral shaft fractures. Part I: Decision-making errors with interlocking fixation.
    Brumback RJ; Reilly JP; Poka A; Lakatos RP; Bathon GH; Burgess AR
    J Bone Joint Surg Am; 1988 Dec; 70(10):1441-52. PubMed ID: 3198668
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Malrotation of Long Bones.
    Sullivan M; Bonilla K; Donegan D
    Orthop Clin North Am; 2021 Jul; 52(3):215-229. PubMed ID: 34053567
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanics of femoral interlocking nails.
    Schandelmaier P; Farouk O; Krettek C; Reimers N; Mannss J; Tscherne H
    Injury; 2000 Jul; 31(6):437-43. PubMed ID: 10831743
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rotational malalignment after closed intramedullary nailing of femoral shaft fractures and its influence on daily life.
    Karaman O; Ayhan E; Kesmezacar H; Seker A; Unlu MC; Aydingoz O
    Eur J Orthop Surg Traumatol; 2014 Oct; 24(7):1243-7. PubMed ID: 23934503
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of malrotation following intramedullary nailing in a femoral shaft fracture model: Can a 3D c-arm improve accuracy?
    Ramme AJ; Egol J; Chang G; Davidovitch RI; Konda S
    Injury; 2017 Jul; 48(7):1603-1608. PubMed ID: 28377262
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.