These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 9020472)

  • 1. The effects of particulate polyethylene at a weight-bearing bone-implant interface.
    Karahan M; Esemenli T
    J Bone Joint Surg Br; 1997 Jan; 79(1):172. PubMed ID: 9020472
    [No Abstract]   [Full Text] [Related]  

  • 2. The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris.
    Bobyn JD; Jacobs JJ; Tanzer M; Urban RM; Aribindi R; Sumner DR; Turner TM; Brooks CE
    Clin Orthop Relat Res; 1995 Feb; (311):21-39. PubMed ID: 7634577
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of particulate polyethylene at a weight-bearing bone-implant interface.
    Karahan M; Esemenli T
    J Bone Joint Surg Br; 1997 Mar; 79(2):340-1. PubMed ID: 9119871
    [No Abstract]   [Full Text] [Related]  

  • 4. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis.
    Nasser S; Campbell PA; Kilgus D; Kossovsky N; Amstutz HC
    Clin Orthop Relat Res; 1990 Dec; (261):171-85. PubMed ID: 2245543
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Prosthesis infection in an immunosuppressed patient].
    de Malet A; Bolaños M; Hernández M; Carranza C
    Enferm Infecc Microbiol Clin; 2010 Oct; 28(8):554-5. PubMed ID: 20381922
    [No Abstract]   [Full Text] [Related]  

  • 6. Evaluation and treatment of infection at the site of a total hip or knee arthroplasty.
    Hanssen AD; Rand JA
    Instr Course Lect; 1999; 48():111-22. PubMed ID: 10098033
    [No Abstract]   [Full Text] [Related]  

  • 7. Wear of high-density polyethylene on bone and cartilage.
    Wroblewski BM
    J Bone Joint Surg Br; 1979 Nov; 61-B(4):498-500. PubMed ID: 387800
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sonication of removed hip and knee prostheses for diagnosis of infection.
    Trampuz A; Piper KE; Jacobson MJ; Hanssen AD; Unni KK; Osmon DR; Mandrekar JN; Cockerill FR; Steckelberg JM; Greenleaf JF; Patel R
    N Engl J Med; 2007 Aug; 357(7):654-63. PubMed ID: 17699815
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Unicompartmental knee arthroplasty to total knee arthroplasty conversion: assuring a primary outcome.
    Berend KR; George J; Lombardi AV
    Orthopedics; 2009 Sep; 32(9):. PubMed ID: 19751000
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hard bearing surfaces in total hip arthroplasty.
    Jazrawi LM; Kummer FJ; Di Cesare PE
    Am J Orthop (Belle Mead NJ); 1998 Apr; 27(4):283-92. PubMed ID: 9586727
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wear in carbon fiber-reinforced polyethylene (poly-two) knee prostheses.
    Busanelli L; Squarzoni S; Brizio L; Tigani D; Sudanese A
    Chir Organi Mov; 1996; 81(3):263-7. PubMed ID: 9009408
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Giant cell synovitis associated with failed polyethylene patellar replacements.
    Ewald FC; Sledge CB; Corson JM; Rose RM; Radin EL
    Clin Orthop Relat Res; 1976; (115):213-9. PubMed ID: 767030
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of particulate polyethylene at a weight-bearing bone-implant interface. A study in rats.
    Allen M; Brett F; Millett P; Rushton N
    J Bone Joint Surg Br; 1996 Jan; 78(1):32-7. PubMed ID: 8898123
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Implant wear mechanisms--basic approach.
    Bhatt H; Goswami T
    Biomed Mater; 2008 Dec; 3(4):042001. PubMed ID: 18824778
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Letter in response to the article on bone and joint infection in the United States: French data.
    Grammatico-Guillon L; Baron S; Gaborit C; Rosset P; Rusch E; Bernard L
    J Arthroplasty; 2013 Jun; 28(6):1055. PubMed ID: 23523488
    [No Abstract]   [Full Text] [Related]  

  • 16. Effect of submicron polyethylene particles on an osseointegrated implant: an experimental study with a rabbit patello-femoral prosthesis.
    Sundfeldt M; Widmark M; Johansson CB; Campbell P; Carlsson LV
    Acta Orthop Scand; 2002 Aug; 73(4):416-24. PubMed ID: 12358115
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lymphadenopathy associated with total joint prostheses. A report of two cases and a review of the literature.
    Benz EB; Sherburne B; Hayek JE; Falchuk KH; Sledge CB; Spector M
    J Bone Joint Surg Am; 1996 Apr; 78(4):588-93. PubMed ID: 8609139
    [No Abstract]   [Full Text] [Related]  

  • 18. Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses.
    Schmalzried TP; Jasty M; Rosenberg A; Harris WH
    J Appl Biomater; 1994; 5(3):185-90. PubMed ID: 10147443
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Antibiotic prophylaxis before invasive dental procedures in patients with arthroplasties of the hip and knee.
    Uçkay I; Pittet D; Bernard L; Lew D; Perrier A; Peter R
    J Bone Joint Surg Br; 2008 Jul; 90(7):833-8. PubMed ID: 18591588
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Infections caused by beta-lactam resistant staphylococci on joint prostheses: diagnosis and treatment].
    Muñoz P; Bouza E
    Rev Clin Esp; 1997 Sep; 197 Suppl 2():38-47. PubMed ID: 9441322
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.