These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 9021059)
1. Feasibility analysis of a case-based reasoning system for automated detection of coronary heart disease from myocardial scintigrams. Haddad M; Adlassnig KP; Porenta G Artif Intell Med; 1997 Jan; 9(1):61-78. PubMed ID: 9021059 [TBL] [Abstract][Full Text] [Related]
2. Automated assessment of dipyridamole 201Tl myocardial SPECT perfusion scintigraphy by case-based reasoning. Khorsand A; Haddad M; Graf S; Moertl D; Sochor H; Porenta G J Nucl Med; 2001 Feb; 42(2):189-93. PubMed ID: 11216515 [TBL] [Abstract][Full Text] [Related]
3. Automated assessment of myocardial SPECT perfusion scintigraphy: a comparison of different approaches of case-based reasoning. Khorsand A; Graf S; Sochor H; Schuster E; Porenta G Artif Intell Med; 2007 Jun; 40(2):103-13. PubMed ID: 17451921 [TBL] [Abstract][Full Text] [Related]
4. Automated interpretation of myocardial SPECT perfusion images using artificial neural networks. Lindahl D; Palmer J; Ohlsson M; Peterson C; Lundin A; Edenbrandt L J Nucl Med; 1997 Dec; 38(12):1870-5. PubMed ID: 9430460 [TBL] [Abstract][Full Text] [Related]
5. Diagnostic performance of an expert system for the interpretation of myocardial perfusion SPECT studies. Garcia EV; Cooke CD; Folks RD; Santana CA; Krawczynska EG; De Braal L; Ezquerra NF J Nucl Med; 2001 Aug; 42(8):1185-91. PubMed ID: 11483678 [TBL] [Abstract][Full Text] [Related]
6. [Diagnosis of chronic coronary failure by clinical aspects, ECG and myocardial scintigraphy after infusion of isoprenaline. Comparison with coronarography]. Pezard P; Geslin P; L'Hoste P; Lejeune JJ; Victor J; Vilayleck S; Jallet P; Tadei A Ann Cardiol Angeiol (Paris); 1989 Mar; 38(3):163-70. PubMed ID: 2735731 [TBL] [Abstract][Full Text] [Related]
7. Adenosine coronary vasodilation quantitative technetium 99m methoxy isobutyl isonitrile myocardial tomography in the identification and localization of coronary artery disease. Nicolai E; Cuocolo A; Pace L; Nappi A; Sullo P; Cardei S; Argenziano L; Squame F; Ell PJ; Salvatore M J Nucl Cardiol; 1996; 3(1):9-17. PubMed ID: 8799223 [TBL] [Abstract][Full Text] [Related]
8. Symbolic reasoning about myocardial scintigrams in PROLOG. Rosenberg S; Itti R; Benjelloun L Eur J Nucl Med; 1986; 12(2):65-8. PubMed ID: 3525173 [TBL] [Abstract][Full Text] [Related]
10. [Interrelation of the state of perfusion and the coronary vascular bed in patients with chronic ischemic heart disease]. Eventov AZ; Matveeva LS; Pariĭskiĭ IuV; Mazaev VP; Pisareva NA Kardiologiia; 1985 Aug; 25(8):46-9. PubMed ID: 4068460 [TBL] [Abstract][Full Text] [Related]
12. The inconsistent pattern of thallium defects: a clue to the false positive perfusion scintigram. Dunn RF; Wolff L; Wagner S; Botvinick EH Am J Cardiol; 1981 Aug; 48(2):224-32. PubMed ID: 7270432 [TBL] [Abstract][Full Text] [Related]
13. [Improvement in the accuracy of diagnosis of ischemic heart disease with simultaneous radioisotope evaluation of regional myocardial function perfusion and an exercise test]. Ciavolella M; Giannitti C; Scali D; Sciarra F; Vicchio D; Reale A Cardiologia; 1990 Feb; 35(2):127-36. PubMed ID: 2208196 [TBL] [Abstract][Full Text] [Related]
14. Comparison of technetium-99m sestamibi left ventricular wall motion and perfusion studies with thallium-201 perfusion imaging: in search of the combination of variables with the highest accuracy in predicting coronary artery disease. Verzijlbergen JF; Zwinderman AH; Ascoop CA; van der Wall EE; Niemeyer MG; Pauwels EK Eur J Nucl Med; 1996 May; 23(5):550-9. PubMed ID: 8698061 [TBL] [Abstract][Full Text] [Related]
15. Cold pressor thallium-201 myocardial scintigraphy in the diagnosis of coronary artery disease. Ahmad M; Dubiel JP; Haibach H Am J Cardiol; 1982 Dec; 50(6):1253-7. PubMed ID: 7148699 [TBL] [Abstract][Full Text] [Related]
16. [Myocardial scintigraphy with Tc-99m-MIBI for assessing the extent and severity of coronary disease: a comparison with thallium-201 and equilibrium angiocardioscintigraphy]. Leoncini M; Sciagrà R; Bisi G; Santoro GM; Fazzini PF G Ital Cardiol; 1993 Feb; 23(2):127-38. PubMed ID: 8491353 [TBL] [Abstract][Full Text] [Related]
17. Additional diagnostic value of integrated analysis of cardiac CTA and SPECT MPI using the SMARTVis system in patients with suspected coronary artery disease. Kirişli HA; Gupta V; Shahzad R; Al Younis I; Dharampal A; Geuns RJ; Scholte AJ; de Graaf MA; Joemai RM; Nieman K; van Vliet L; van Walsum T; Lelieveldt B; Niessen WJ J Nucl Med; 2014 Jan; 55(1):50-7. PubMed ID: 24337600 [TBL] [Abstract][Full Text] [Related]
18. Is quantitative analysis superior to visual analysis of planar thallium 201 myocardial exercise scintigraphy in the evaluation of coronary artery disease? Analysis of a prospective clinical study. Niemeyer MG; Laarman GJ; van der Wall EE; Cramer MJ; Verzijlbergen FJ; Zwinderman AH; Ascoop CA; Pauwels EK Eur J Nucl Med; 1990; 16(8-10):697-704. PubMed ID: 2384105 [TBL] [Abstract][Full Text] [Related]
19. [Myocardial scintigraphy with Tc-99m-teboroxime: its feasibility and the evaluation of its diagnostic reliability. A comparison with thallium-201 and coronary angiography]. Bisi G; Sciagrà R; Santoro GM; Cerisano G; Vella A; Zerauschek F; Fazzini PF G Ital Cardiol; 1992 Jul; 22(7):795-805. PubMed ID: 1473653 [TBL] [Abstract][Full Text] [Related]