257 related articles for article (PubMed ID: 9025049)
1. Experimental nonsurgical transcervical sterilization with a custom-designed platinum microcoil.
Post JH; Cardella JF; Wilson RP; Griffith JW; Fox PS; Waybill PN; Hills JR
J Vasc Interv Radiol; 1997; 8(1 Pt 1):113-8. PubMed ID: 9025049
[TBL] [Abstract][Full Text] [Related]
2. Experimental nonsurgical female sterilization: transcervical implantation of microspindles in fallopian tubes.
Schmitz-Rode T; Ross PL; Timmermans H; Thurmond AS; Günther RW; Rösch J
J Vasc Interv Radiol; 1994; 5(6):905-10. PubMed ID: 7873873
[TBL] [Abstract][Full Text] [Related]
3. Tubal sterilization by means of selective catheterization: comparison of a hydrogel and a collagen glue.
Maubon AJ; Thurmond AS; Laurent A; Machan LS; Scanlan RM; Nikolchev J; Rouanet JP
J Vasc Interv Radiol; 1996; 7(5):733-6. PubMed ID: 8897343
[TBL] [Abstract][Full Text] [Related]
4. Selective tubal sterilization in rabbits: experience with a hydrogel combined with a sclerosing agent.
Maubon AJ; Thurmond AS; Laurent A; Honiger JE; Scanlan RM; Rouanet JP
Radiology; 1994 Dec; 193(3):721-3. PubMed ID: 7972813
[TBL] [Abstract][Full Text] [Related]
5. Tubal sterilization by selective catheterization in an animal model.
Maubon A; Rouanet JP; Laurent A; Joujoux JM; Cover S; Courtieu C; Wassef M; Godlewski G; Honiger J; Lopez FM
Invest Radiol; 1994 Feb; 29(2):156-61. PubMed ID: 8169090
[TBL] [Abstract][Full Text] [Related]
6. Transcatheter tubal sterilization in rabbits. Technique and results.
Ross PL; Thurmond AS; Uchida BT; Jones MK; Scanlan RM; Kessel E
Invest Radiol; 1994 May; 29(5):570-3. PubMed ID: 8077098
[TBL] [Abstract][Full Text] [Related]
7. Efficacy and safety of repeated transcervical quinacrine pellet insertions for female sterilization.
el Kady AA; Nagib HS; Kessel E
Fertil Steril; 1993 Feb; 59(2):301-4. PubMed ID: 8425622
[TBL] [Abstract][Full Text] [Related]
8. Sterilization with methyl cyanoacrylate-induced fallopian tube occlusion from a nonsurgical transvaginal approach in rabbits.
Berkey GS; Nelson R; Zuckerman AM; Dillehay D; Cope C
J Vasc Interv Radiol; 1995; 6(5):669-74. PubMed ID: 8541665
[TBL] [Abstract][Full Text] [Related]
9. Occlusion of the fallopian tube by selective transcatheter radiofrequency electrocoagulation: an experimental study in rabbits.
Seo TS; Oh JH; Yoon Y; Ryu KN; Lim JW
J Vasc Interv Radiol; 2002 Apr; 13(4):399-404. PubMed ID: 11932371
[TBL] [Abstract][Full Text] [Related]
10. Transcervical sterilization with use of methyl 2-cyanoacrylate and a newer delivery system (the FEMCEPT device).
Shuber J
Am J Obstet Gynecol; 1989 Apr; 160(4):887-9. PubMed ID: 2712121
[TBL] [Abstract][Full Text] [Related]
11. Use of ethylene vinyl alcohol copolymer for tubal sterilization by selective catheterization in rabbits.
Abdala N; Levitin A; Dawson A; Maffra R; Munoz-Ramirez H; Godec K; Dolmatch BL
J Vasc Interv Radiol; 2001 Aug; 12(8):979-84. PubMed ID: 11487679
[TBL] [Abstract][Full Text] [Related]
12. Transcervical tubal cannulation, past, present, and future.
Risquez F; Confino E
Fertil Steril; 1993 Aug; 60(2):211-26. PubMed ID: 8339814
[TBL] [Abstract][Full Text] [Related]
13. Diode laser assisted transcervical tubal sterilization: an in vivo study in rabbits.
Spörri S; Bell B; Yandell R; Motamedi M
Lasers Surg Med; 2001; 29(4):379-85. PubMed ID: 11746117
[TBL] [Abstract][Full Text] [Related]
14. Laparoscopic sterilization in the supine position using the Ramathibodi uterine manipulator.
Blumenthal PD
Fertil Steril; 1995 Jul; 64(1):204-7. PubMed ID: 7789563
[TBL] [Abstract][Full Text] [Related]
15. Tubal sterilization by means of endoluminal coagulation: an in vivo study in rabbits.
Spörri S; Bell B; Dreher E; Schneider H; Motamedi M
Contraception; 2000 Sep; 62(3):141-7. PubMed ID: 11124362
[TBL] [Abstract][Full Text] [Related]
16. Failed reversal of sterilization: transcervical transostial recannulation of occluded fallopian tube.
Dunphy BC; Greene C
Am J Obstet Gynecol; 1994 Jul; 171(1):274-5. PubMed ID: 8030716
[TBL] [Abstract][Full Text] [Related]
17. The influence of fallopian tube length on fertility in the rabbit.
McComb P; Gomel V
Fertil Steril; 1979 Jun; 31(6):673-6. PubMed ID: 446793
[TBL] [Abstract][Full Text] [Related]
18. Fallopian tube occlusion with use of a small intestine submucosa device: evaluation in a rabbit model.
Binkert CA; Pavcnik D; Andrews RT; Loriaux MM; Uchida B; Brountzos EN; Rösch J
J Vasc Interv Radiol; 2004 Jun; 15(6):609-13. PubMed ID: 15178722
[TBL] [Abstract][Full Text] [Related]
19. Diagnosis and treatment of proximal tubal obstruction by fluoroscopic transcervical fallopian tube catheterization.
Sowa M; Shimamoto T; Nakano R; Sato M; Yamada R
Hum Reprod; 1993 Oct; 8(10):1711-4. PubMed ID: 8300835
[TBL] [Abstract][Full Text] [Related]
20. The value of hysterosalpingography before reversal of sterilization procedures involving the fallopian tubes.
Karasick S; Ehrlich S
AJR Am J Roentgenol; 1989 Dec; 153(6):1247-50. PubMed ID: 2816643
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]