BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 9027019)

  • 1. [Radiation burden to the hands of surgeons in intramedullary nailing].
    Müller LP; Suffner J; Wenda K; Mohr W; Rudig L
    Unfallchirurgie; 1996 Dec; 22(6):253-9. PubMed ID: 9027019
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing.
    Müller LP; Suffner J; Wenda K; Mohr W; Rommens PM
    Injury; 1998 Jul; 29(6):461-8. PubMed ID: 9813705
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radiation exposure to the surgeon during closed interlocking intramedullary nailing.
    Levin PE; Schoen RW; Browner BD
    J Bone Joint Surg Am; 1987 Jun; 69(5):761-6. PubMed ID: 3597477
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiation exposure to the surgeon during femoral interlocking nailing under fluoroscopic imaging.
    Muzaffar TS; Imran Y; Iskandar MA; Zakaria A
    Med J Malaysia; 2005 Jul; 60 Suppl C():26-9. PubMed ID: 16381279
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Exposure of the orthopaedic surgeon to radiation.
    Sanders R; Koval KJ; DiPasquale T; Schmelling G; Stenzler S; Ross E
    J Bone Joint Surg Am; 1993 Mar; 75(3):326-30. PubMed ID: 8444910
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb.
    Madan S; Blakeway C
    Injury; 2002 Oct; 33(8):723-7. PubMed ID: 12213425
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Effectiveness of lead thyroid shield for reducing roentgen ray exposure in trauma surgery interventions of the lower leg].
    Müller LP; Suffner J; Mohr W; Degreif J; Rommens PM
    Unfallchirurgie; 1997 Dec; 23(6):246-51. PubMed ID: 9483787
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Radiation-sparing intramedullary nailing with a radiolucent drilling system].
    Rosso R; Vogelbach P; Babst R; Messmer P; Regazzoni P
    Helv Chir Acta; 1992 Aug; 59(2):423-5. PubMed ID: 1428937
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures.
    Coetzee JC; van der Merwe EJ
    S Afr Med J; 1992 Mar; 81(6):312-4. PubMed ID: 1570580
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A simple, rapid and economical method of distal interlocking nailing in upper and lower leg intramedullary nailing].
    Friedl W
    Chirurg; 1991 May; 62(5):423-5. PubMed ID: 1874047
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetry during intramedullary nailing of the tibia.
    Kirousis G; Delis H; Megas P; Lambiris E; Panayiotakis G
    Acta Orthop; 2009 Oct; 80(5):568-72. PubMed ID: 19916691
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: a clinical study.
    Blattert TR; Fill UA; Kunz E; Panzer W; Weckbach A; Regulla DF
    Arch Orthop Trauma Surg; 2004 Dec; 124(10):659-64. PubMed ID: 15365718
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiation Exposure to the Surgeon, Surgical Assistant, and Scrub Nurse During Closed Intramedullary Nailing of Long Bones-Does It Vary Depending on the Experience of the Surgeon?
    Patra SK; Shetty AP; Jayaramaraju D; Rajasekaran S
    J Orthop Trauma; 2019 Feb; 33(2):e52-e57. PubMed ID: 30489427
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: a prospective study.
    Ahn Y; Kim CH; Lee JH; Lee SH; Kim JS
    Spine (Phila Pa 1976); 2013 Apr; 38(7):617-25. PubMed ID: 23026867
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiation Exposure to Surgeon and Assistant During Flat Panel Mini C-Arm Fluoroscopy in Hand and Wrist Surgical Procedures.
    van Rappard JRM; de Jong T; Hummel WA; Ritt MJPF; Mouës CM
    J Hand Surg Am; 2019 Jan; 44(1):68.e1-68.e5. PubMed ID: 29934087
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Elastic stable intramedullary nailing in pediatric femur and lower leg shaft fractures: intraoperative radiation load.
    Kraus R; Schiefer U; Schäfer C; Meyer C; Schnettler R
    J Pediatr Orthop; 2008; 28(1):14-6. PubMed ID: 18157040
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiation exposure of the hands and thyroid gland during percutaneous wiring of wrist and hand procedures.
    Bahari S; Morris S; Broe D; Taylor C; Lenehan B; McElwain J
    Acta Orthop Belg; 2006 Apr; 72(2):194-8. PubMed ID: 16768265
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Augmentation plate fixation for the treatment of femoral and tibial nonunion after intramedullary nailing.
    Birjandinejad A; Ebrahimzadeh MH; Ahmadzadeh-Chabock H
    Orthopedics; 2009 Jun; 32(6):409. PubMed ID: 19634823
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Change in the procedure from external fixator to intramedullary nailing osteosynthesis of the femur and tibia].
    Höntzsch D; Weller S; Engels C; Kaiserauer S
    Aktuelle Traumatol; 1993 Jul; 23 Suppl 1():21-35. PubMed ID: 8104380
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Getting the rotation right: techniques for assessing rotation in intramedullary tibial and femoral nailing.
    Hak DJ
    Orthopedics; 2011 Jan; 34(1):33. PubMed ID: 21210587
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.