These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
129 related articles for article (PubMed ID: 9029394)
1. A comparison of the hydrodynamical behaviour of three heart aortic prostheses by numerical methods. Cerrolaza M; Herrera M; Berrios R; Annichiaricco W J Med Eng Technol; 1996; 20(6):219-28. PubMed ID: 9029394 [TBL] [Abstract][Full Text] [Related]
2. Numerical analysis of three-dimensional Björk-Shiley valvular flow in an aorta. Shim EB; Chang KS J Biomech Eng; 1997 Feb; 119(1):45-51. PubMed ID: 9083848 [TBL] [Abstract][Full Text] [Related]
3. Effect of heart rate on the hemodynamics of bileaflet mechanical heart valves' prostheses (St. Jude Medical) in the aortic position and in the opening phase: A computational study. Jahandardoost M; Fradet G; Mohammadi H Proc Inst Mech Eng H; 2016 Mar; 230(3):175-90. PubMed ID: 26786673 [TBL] [Abstract][Full Text] [Related]
4. Numerical simulation of unsteady laminar flow through a tilting disk heart valve: prediction of vortex shedding. Huang ZJ; Merkle CL; Abdallah S; Tarbell JM J Biomech; 1994 Apr; 27(4):391-402. PubMed ID: 8188720 [TBL] [Abstract][Full Text] [Related]
5. Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: an in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves. Baumgartner H; Khan S; DeRobertis M; Czer L; Maurer G J Am Coll Cardiol; 1992 Feb; 19(2):324-32. PubMed ID: 1531058 [TBL] [Abstract][Full Text] [Related]
8. Analysis of 3D transient blood flow passing through an artificial aortic valve by Lattice-Boltzmann methods. Krafczyk M; Cerrolaza M; Schulz M; Rank E J Biomech; 1998 May; 31(5):453-62. PubMed ID: 9727343 [TBL] [Abstract][Full Text] [Related]
9. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves. Reul H; van Son JA; Steinseifer U; Schmitz B; Schmidt A; Schmitz C; Rau G J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181 [TBL] [Abstract][Full Text] [Related]
10. Comparative study of the hydrodynamic function of six size 19 mm bileaflet heart valves. Fisher J Eur J Cardiothorac Surg; 1995; 9(12):692-5 discussion 695-6. PubMed ID: 8703490 [TBL] [Abstract][Full Text] [Related]
11. Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model. Perktold K; Rappitsch G J Biomech; 1995 Jul; 28(7):845-56. PubMed ID: 7657682 [TBL] [Abstract][Full Text] [Related]
12. A three-dimensional computational analysis of fluid-structure interaction in the aortic valve. De Hart J; Peters GW; Schreurs PJ; Baaijens FP J Biomech; 2003 Jan; 36(1):103-12. PubMed ID: 12485644 [TBL] [Abstract][Full Text] [Related]
13. Numerical dye washout method as a tool for characterizing the heart valve flow: study of three standard mechanical heart valves. Goubergrits L; Kertzscher U; Affeld K; Petz C; Stalling D; Hege HC ASAIO J; 2008; 54(1):50-7. PubMed ID: 18204316 [TBL] [Abstract][Full Text] [Related]
14. Turbulent stresses downstream of three mechanical aortic valve prostheses in human beings. Nygaard H; Paulsen PK; Hasenkam JM; Pedersen EM; Rovsing PE J Thorac Cardiovasc Surg; 1994 Feb; 107(2):438-46. PubMed ID: 8302062 [TBL] [Abstract][Full Text] [Related]
15. Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography. Panidis IP; Ross J; Mintz GS J Am Coll Cardiol; 1986 Aug; 8(2):317-26. PubMed ID: 2942593 [TBL] [Abstract][Full Text] [Related]
16. In vitro flow dynamics of four prosthetic aortic valves: a comparative analysis. Hanle DD; Harrison EC; Yoganathan AP; Allen DT; Corcoran WH J Biomech; 1989; 22(6-7):597-607. PubMed ID: 2808443 [TBL] [Abstract][Full Text] [Related]
17. Computer simulation of convective diffusion processes in large arteries. Rappitsch G; Perktold K J Biomech; 1996 Feb; 29(2):207-15. PubMed ID: 8849814 [TBL] [Abstract][Full Text] [Related]
18. A comparative computational study of blood flow through prosthetic heart valves using the finite element method. Idelsohn SR; Costa LE; Ponso R J Biomech; 1985; 18(2):97-115. PubMed ID: 3988789 [TBL] [Abstract][Full Text] [Related]
19. Numerical simulations of steady flow inside a three dimensional aortic bifurcation model. Wille SO J Biomed Eng; 1984 Jan; 6(1):49-55. PubMed ID: 6694368 [TBL] [Abstract][Full Text] [Related]
20. Effect of mechanical aortic valve orientation on coronary artery flow: comparison of tilting disc versus bileaflet prostheses in pigs. Kleine P; Scherer M; Abdel-Rahman U; Klesius AA; Ackermann H; Moritz A J Thorac Cardiovasc Surg; 2002 Nov; 124(5):925-32. PubMed ID: 12407375 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]