394 related articles for article (PubMed ID: 9029544)
1. Reporting and analyzing dose distributions: a concept of equivalent uniform dose.
Niemierko A
Med Phys; 1997 Jan; 24(1):103-10. PubMed ID: 9029544
[TBL] [Abstract][Full Text] [Related]
2. Optimization of equivalent uniform dose using the L-curve criterion.
Chvetsov AV; Dempsey JF; Palta JR
Phys Med Biol; 2007 Oct; 52(19):5973-84. PubMed ID: 17881813
[TBL] [Abstract][Full Text] [Related]
3. Biologically effective uniform dose (D) for specification, report and comparison of dose response relations and treatment plans.
Mavroidis P; Lind BK; Brahme A
Phys Med Biol; 2001 Oct; 46(10):2607-30. PubMed ID: 11686278
[TBL] [Abstract][Full Text] [Related]
4. EUD-based biological optimization for carbon ion therapy.
Brüningk SC; Kamp F; Wilkens JJ
Med Phys; 2015 Nov; 42(11):6248-57. PubMed ID: 26520717
[TBL] [Abstract][Full Text] [Related]
5. Using FDG-PET activity as a surrogate for tumor cell density and its effect on equivalent uniform dose calculation.
Zhou SM; Wong TZ; Marks LB
Med Phys; 2004 Sep; 31(9):2577-83. PubMed ID: 15487740
[TBL] [Abstract][Full Text] [Related]
6. Limitations of a convolution method for modeling geometric uncertainties in radiation therapy: the radiobiological dose-per-fraction effect.
Song W; Battista J; Van Dyk J
Med Phys; 2004 Nov; 31(11):3034-45. PubMed ID: 15587657
[TBL] [Abstract][Full Text] [Related]
7. The modelled benefits of individualizing radiotherapy patients' dose using cellular radiosensitivity assays with inherent variability.
Mackay RI; Hendry JH
Radiother Oncol; 1999 Jan; 50(1):67-75. PubMed ID: 10225559
[TBL] [Abstract][Full Text] [Related]
8. Applying the equivalent uniform dose formulation based on the linear-quadratic model to inhomogeneous tumor dose distributions: Caution for analyzing and reporting.
McGary JE; Grant W; Woo SY
J Appl Clin Med Phys; 2000; 1(4):126-37. PubMed ID: 11674828
[TBL] [Abstract][Full Text] [Related]
9. Viability of the EUD and TCP concepts as reliable dose indicators.
Ebert MA
Phys Med Biol; 2000 Feb; 45(2):441-57. PubMed ID: 10701514
[TBL] [Abstract][Full Text] [Related]
10. EUD-based radiotherapy treatment plan evaluation: incorporating physical and Monte Carlo statistical dose uncertainties.
Cranmer-Sargison G; Zavgorodni S
Phys Med Biol; 2005 Sep; 50(17):4097-109. PubMed ID: 16177533
[TBL] [Abstract][Full Text] [Related]
11. Response-probability volume histograms and iso-probability of response charts in treatment plan evaluation.
Mavroidis P; Ferreira BC; Lopes Mdo C
Med Phys; 2011 May; 38(5):2382-97. PubMed ID: 21776773
[TBL] [Abstract][Full Text] [Related]
12. A general tumour control probability model for non-uniform dose distributions.
González SJ; Carando DG
Math Med Biol; 2008 Jun; 25(2):171-84. PubMed ID: 18515259
[TBL] [Abstract][Full Text] [Related]
13. From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning.
Thieke C; Bortfeld T; Niemierko A; Nill S
Med Phys; 2003 Sep; 30(9):2332-9. PubMed ID: 14528955
[TBL] [Abstract][Full Text] [Related]
14. A role for biological optimization within the current treatment planning paradigm.
Das S
Med Phys; 2009 Oct; 36(10):4672-82. PubMed ID: 19928099
[TBL] [Abstract][Full Text] [Related]
15. Characterization of dose distributions through the max and mean dose concept.
Thieke C; Bortfeld T; Küfer KH
Acta Oncol; 2002; 41(2):158-61. PubMed ID: 12102160
[TBL] [Abstract][Full Text] [Related]
16. Biological optimization of heterogeneous dose distributions in systemic radiotherapy.
Strigari L; D'Andrea M; Maini CL; Sciuto R; Benassi M
Med Phys; 2006 Jun; 33(6):1857-66. PubMed ID: 16872093
[TBL] [Abstract][Full Text] [Related]
17. On relating the generalized equivalent uniform dose formalism to the linear-quadratic model.
Djajaputra D; Wu Q
Med Phys; 2006 Dec; 33(12):4481-9. PubMed ID: 17278799
[TBL] [Abstract][Full Text] [Related]
18. Modeling dose response in the presence of spatial variations in dose rate.
Ebert MA; Zavgorodni SF
Med Phys; 2000 Feb; 27(2):393-400. PubMed ID: 10718144
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: a volumetric dose measurement study.
Duan J; Shen S; Fiveash JB; Popple RA; Brezovich IA
Med Phys; 2006 May; 33(5):1380-7. PubMed ID: 16752574
[TBL] [Abstract][Full Text] [Related]
20. Development of an inverse optimization package to plan nonuniform dose distributions based on spatially inhomogeneous radiosensitivity extracted from biological images.
Chen GP; Ahunbay E; Schultz C; Li XA
Med Phys; 2007 Apr; 34(4):1198-205. PubMed ID: 17500451
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]