151 related articles for article (PubMed ID: 9032635)
1. Evaluation of the efficacy of a 3.2% glutaraldehyde product for disinfection of fibreoptic endoscopes with an automatic machine.
Akamatsu T; Tabata K; Hironaga M; Uyeda M
J Hosp Infect; 1997 Jan; 35(1):47-57. PubMed ID: 9032635
[TBL] [Abstract][Full Text] [Related]
2. Cleaning and disinfection of fiberoptic endoscopes: evaluation of glutaraldehyde exposure time and forced-air drying.
Gerding DN; Peterson LR; Vennes JA
Gastroenterology; 1982 Sep; 83(3):613-8. PubMed ID: 6807738
[TBL] [Abstract][Full Text] [Related]
3. Microbial bioburden in endoscope reprocessing and an in-use evaluation of the high-level disinfection capabilities of Cidex PA.
Vesley D; Melson J; Stanley P
Gastroenterol Nurs; 1999; 22(2):63-8. PubMed ID: 10382415
[TBL] [Abstract][Full Text] [Related]
4. In-hospital evaluation of 7.5% hydrogen peroxide as a disinfectant for flexible endoscopes.
Sattar SA; Taylor YE; Paquette M; Rubino J
Can J Infect Control; 1996; 11(2):51-4. PubMed ID: 8868803
[TBL] [Abstract][Full Text] [Related]
5. Deficiencies of automatic endoscopic reprocessors: a method to achieve high-grade disinfection of endoscopes.
Ido K; Ishino Y; Ota Y; Kihira K; Taniguchi Y; Saifuku K; Satoh K; Kawamoto C; Hayashi M; Kimura K
Gastrointest Endosc; 1996 Nov; 44(5):583-6. PubMed ID: 8934166
[TBL] [Abstract][Full Text] [Related]
6. Endoscope decontamination: a comparison of the Wolf 35100 and DSD-91 systems.
Corcoran GD; Holton J; Ridgway GL
J Hosp Infect; 1994 Aug; 27(4):307-15. PubMed ID: 7963473
[TBL] [Abstract][Full Text] [Related]
7. Sporicidal activity of disinfectants as one possible cause for bacteria in patient-ready endoscopes.
Miner N; Harris V; Ebron T; Cao TD
Gastroenterol Nurs; 2007; 30(4):285-90. PubMed ID: 17724404
[TBL] [Abstract][Full Text] [Related]
8. Viral transmission and fibreoptic endoscopy.
Hanson PJ; Jeffries DJ; Collins JV
J Hosp Infect; 1991 Jun; 18 Suppl A():136-40. PubMed ID: 1679776
[TBL] [Abstract][Full Text] [Related]
9. Disinfection of upper gastrointestinal fibreoptic endoscopy equipment: an evaluation of a cetrimide chlorhexidine solution and glutaraldehyde.
Carr-Locke DL; Clayton P
Gut; 1978 Oct; 19(10):916-22. PubMed ID: 101424
[TBL] [Abstract][Full Text] [Related]
10. Efficacy of routine fiberoptic endoscope cleaning and disinfection for killing Clostridium difficile.
Hughes CE; Gebhard RL; Peterson LR; Gerding DN
Gastrointest Endosc; 1986 Feb; 32(1):7-9. PubMed ID: 3081401
[TBL] [Abstract][Full Text] [Related]
11. Unsuspected dilution of glutaraldehyde in an automatic washer for flexible fibreoptic endoscopes.
Whyman CA; McDonald SA; Zoutman D
Can J Infect Control; 1991; 6(4):91-3. PubMed ID: 1843622
[TBL] [Abstract][Full Text] [Related]
12. Residual glutaraldehyde levels in fiberoptic endoscopes: measurement and implications for patient toxicity.
Farina A; Fievet MH; Plassart F; Menet MC; Thuillier A
J Hosp Infect; 1999 Dec; 43(4):293-7. PubMed ID: 10658805
[TBL] [Abstract][Full Text] [Related]
13. Glutaraldehyde-resistant Mycobacterium chelonae from endoscope washer disinfectors.
Griffiths PA; Babb JR; Bradley CR; Fraise AP
J Appl Microbiol; 1997 Apr; 82(4):519-26. PubMed ID: 9190297
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of three glutaraldehyde-based disinfectants used in endoscopy.
Jetté LP; Ringuette L; Ishak M; Miller M; Saint-Antoine P
J Hosp Infect; 1995 Aug; 30(4):295-303. PubMed ID: 7499810
[TBL] [Abstract][Full Text] [Related]
15. Efficacy of electrolyzed acid water in reprocessing patient-used flexible upper endoscopes: Comparison with 2% alkaline glutaraldehyde.
Lee JH; Rhee PL; Kim JH; Kim JJ; Paik SW; Rhee JC; Song JH; Yeom JS; Lee NY
J Gastroenterol Hepatol; 2004 Aug; 19(8):897-903. PubMed ID: 15242493
[TBL] [Abstract][Full Text] [Related]
16. Endoscope disinfection by ortho-phthalaldehyde in a clinical setting: an evaluation of reprocessing time and costs compared with glutaraldehyde.
Hession SM
Gastroenterol Nurs; 2003; 26(3):110-4. PubMed ID: 12811321
[TBL] [Abstract][Full Text] [Related]
17. Elimination of high titre HIV from fibreoptic endoscopes.
Hanson PJ; Gor D; Jeffries DJ; Collins JV
Gut; 1990 Jun; 31(6):657-9. PubMed ID: 2379868
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of the effectiveness of an enzymatic cleaner and glutaraldehyde-based disinfectant for chemothermal processing of flexible endoscopes in washer-disinfectors in accordance with prEN ISO 15 883.
Zühlsdorf B; Kampf G
Endoscopy; 2006 Jun; 38(6):586-91. PubMed ID: 16612746
[TBL] [Abstract][Full Text] [Related]
19. Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee.
BSG E
Gut; 1998 Apr; 42(4):585-93. PubMed ID: 9616326
[TBL] [Abstract][Full Text] [Related]
20. Comparison of automated systems for the cleaning and disinfection of flexible fibreoptic endoscopes.
Babb JR; Bradley CR; Ayliffe GA
J Hosp Infect; 1984 Jun; 5(2):213-26. PubMed ID: 6205063
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]