109 related articles for article (PubMed ID: 9032848)
1. An evaluation of the accuracy of magnetic-resonance-guided Gamma Knife surgery.
Guo WY; Chu WC; Wu MC; Chung WY; Gwan WP; Lee YL; Pan HC; Chang CY
Stereotact Funct Neurosurg; 1996; 66 Suppl 1():85-92. PubMed ID: 9032848
[TBL] [Abstract][Full Text] [Related]
2. Mechanical and dose delivery accuracy evaluation in radiosurgery using polymer gels.
Sandilos P; Tatsis E; Vlachos L; Karaiskos P; Georgiou E; Kipouros P; Torrens M; Angelopoulos A
J Appl Clin Med Phys; 2006 Nov; 7(4):13-21. PubMed ID: 17533353
[TBL] [Abstract][Full Text] [Related]
3. Application of polymer gel dosimetry in gamma knife radiosurgery.
Novotný J; Novotný J; Spevácek V; Dvorák P; Cechak T; Liscák R; Brozek G; Tintĕra J; Vymazal J
J Neurosurg; 2002 Dec; 97(5 Suppl):556-62. PubMed ID: 12507096
[TBL] [Abstract][Full Text] [Related]
4. Quality control of the stereotactic radiosurgery procedure with the polymer-gel dosimetry.
Novotný J; Dvorák P; Spevácek V; Tintera J; Novotný J; Cechák T; Liscák R
Radiother Oncol; 2002 May; 63(2):223-30. PubMed ID: 12063013
[TBL] [Abstract][Full Text] [Related]
5. Assessment and characterization of the total geometric uncertainty in Gamma Knife radiosurgery using polymer gels.
Moutsatsos A; Karaiskos P; Petrokokkinos L; Sakelliou L; Pantelis E; Georgiou E; Torrens M; Seimenis I
Med Phys; 2013 Mar; 40(3):031704. PubMed ID: 23464299
[TBL] [Abstract][Full Text] [Related]
6. Three-dimensional dose mapping from gamma knife treatment using a dosimeter gel and MR-imaging.
Olsson LE; Arndt J; Fransson A; Nordell B
Radiother Oncol; 1992 Jun; 24(2):82-6. PubMed ID: 1496146
[TBL] [Abstract][Full Text] [Related]
7. Do we need conventional angiography? The role of magnetic resonance imaging in verifying obliteration of arteriovenous malformations after Gamma Knife surgery.
Guo WY; Pan HC; Chung WY; Wang LW; Teng MM
Stereotact Funct Neurosurg; 1996; 66 Suppl 1():71-84. PubMed ID: 9032847
[TBL] [Abstract][Full Text] [Related]
8. An evaluation of the TSE MR sequence for time efficient data acquisition in polymer gel dosimetry of applications involving high doses and steep dose gradients.
Baras P; Seimenis I; Sandilos P; Vlahos L; Bieganski T; Georgiou E; Pantelis E; Papagiannis P; Sakelliou L
Med Phys; 2005 Nov; 32(11):3339-45. PubMed ID: 16370420
[TBL] [Abstract][Full Text] [Related]
9. Quality assurance in stereotactic space. A system test for verifying the accuracy of aim in radiosurgery.
Mack A; Czempiel H; Kreiner HJ; Dürr G; Wowra B
Med Phys; 2002 Apr; 29(4):561-8. PubMed ID: 11991128
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of dose delivery accuracy of Gamma Knife by polymer gel dosimetry.
Watanabe Y; Akimitsu T; Hirokawa Y; Mooij RB; Perera GM
J Appl Clin Med Phys; 2005; 6(3):133-42. PubMed ID: 16143798
[TBL] [Abstract][Full Text] [Related]
11. Accuracy and stability of positioning in radiosurgery: long-term results of the Gamma Knife system.
Heck B; Jess-Hempen A; Kreiner HJ; Schöpgens H; Mack A
Med Phys; 2007 Apr; 34(4):1487-95. PubMed ID: 17500479
[TBL] [Abstract][Full Text] [Related]
12. Accuracy of an experimental stereotactic system for MRI-based gamma knife irradiation in the rat.
Kamiryo T; Berr SS; Berk HW; Lee KS; Kassell NF; Steiner L
Acta Neurochir (Wien); 1996; 138(9):1103-7; discussion 1107-8. PubMed ID: 8911549
[TBL] [Abstract][Full Text] [Related]
13. Coordinate transformation after stereotactic frame reapplication in Gamma Knife radiosurgery.
Park JH; Chung HT; Kim DG; Kim YH; Han JH; Kim CY; Oh CW; Suh TS
Phys Med; 2014 Mar; 30(2):171-7. PubMed ID: 23764297
[TBL] [Abstract][Full Text] [Related]
14. MRI-based polymer gel dosimetry for validating plans with multiple matrices in Gamma Knife stereotactic radiosurgery.
Gopishankar N; Watanabe Y; Subbiah V
J Appl Clin Med Phys; 2011 Jan; 12(2):3333. PubMed ID: 21587176
[TBL] [Abstract][Full Text] [Related]
15. Target localization accuracy in frame-based stereotactic radiosurgery: Comparison between MR-only and MR/CT co-registration approaches.
Pappas EP; Seimenis I; Kouris P; Theocharis S; Lampropoulos KI; Kollias G; Karaiskos P
J Appl Clin Med Phys; 2022 May; 23(5):e13580. PubMed ID: 35285583
[TBL] [Abstract][Full Text] [Related]
16. Commissioning Intracranial Stereotactic Radiosurgery for a Magnetic Resonance-Guided Radiation Therapy (MRgRT) System: MR-RT Localization and Dosimetric End-to-End Validation.
Mittauer KE; Tolakanahalli R; Kotecha R; Chuong MD; Mehta MP; Gutierrez AN; Bassiri N
Int J Radiat Oncol Biol Phys; 2024 Feb; 118(2):512-524. PubMed ID: 37793574
[TBL] [Abstract][Full Text] [Related]
17. High-resolution dose profile studies based on MR imaging with polymer BANG(TM) gels in stereotactic radiation techniques.
Ertl A; Berg A; Zehetmayer M; Frigo P
Magn Reson Imaging; 2000 Apr; 18(3):343-9. PubMed ID: 10745144
[TBL] [Abstract][Full Text] [Related]
18. End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia.
Brezovich IA; Wu X; Duan J; Popple RA; Shen S; Benhabib S; Huang M; Christian Dobelbower M; Fisher WS
Med Phys; 2014 Nov; 41(11):111703. PubMed ID: 25370617
[TBL] [Abstract][Full Text] [Related]
19. A simple method for evaluating stereotactic accuracy of Magnetic Resonance Imaging and Computed Tomography Imaging in Frame Based Radiosurgery.
Sajeev T; Musthafa M; Sampath S; Indiradevi B; Bhanumathy G; Supe SS
Gulf J Oncolog; 2013 Jul; 1(14):6-13. PubMed ID: 23996861
[TBL] [Abstract][Full Text] [Related]
20. Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy.
Crescenti RA; Scheib SG; Schneider U; Gianolini S
Med Phys; 2007 Apr; 34(4):1286-97. PubMed ID: 17500460
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]