BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 9039349)

  • 41. The influence of the chemical composition and surface of the implant on infection.
    Cordero J; Munuera L; Folgueira MD
    Injury; 1996; 27 Suppl 3():SC34-7. PubMed ID: 9039352
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Corrosion on spinal implants.
    Kirkpatrick JS; Venugopalan R; Beck P; Lemons J
    J Spinal Disord Tech; 2005 Jun; 18(3):247-51. PubMed ID: 15905769
    [TBL] [Abstract][Full Text] [Related]  

  • 43. In vivo corrosion of 316L stainless-steel hip implants: morphology and elemental compositions of corrosion products.
    Walczak J; Shahgaldi F; Heatley F
    Biomaterials; 1998; 19(1-3):229-37. PubMed ID: 9678872
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A combined metallurgical and histological study of tissue-prosthesis interactions in orthopedic patients.
    Williams DF; Meachim G
    J Biomed Mater Res; 1974; 8(3):1-9. PubMed ID: 4616962
    [No Abstract]   [Full Text] [Related]  

  • 45. The effect of mucin, fibrinogen and IgG on the corrosion behaviour of Ni-Ti alloy and stainless steel.
    Chao Z; Yaomu X; Chufeng L; Conghua L
    Biometals; 2017 Jun; 30(3):367-377. PubMed ID: 28343289
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Effects of simulated inflammation on the corrosion of 316L stainless steel.
    Brooks EK; Brooks RP; Ehrensberger MT
    Mater Sci Eng C Mater Biol Appl; 2017 Feb; 71():200-205. PubMed ID: 27987699
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Surface modification of titanium alloy implants.
    Browne M; Gregson PJ
    Biomaterials; 1994 Sep; 15(11):894-8. PubMed ID: 7833436
    [TBL] [Abstract][Full Text] [Related]  

  • 48. In vitro crevice corrosion behavior of implant materials.
    Sutow EJ; Jones DW; Milne EL
    J Dent Res; 1985 May; 64(5):842-7. PubMed ID: 3858307
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Retention of asymptomatic bone plates used for orthognathic surgery and facial fractures.
    Haug RH
    J Oral Maxillofac Surg; 1996 May; 54(5):611-7. PubMed ID: 8632246
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Variations in surface characteristics and corrosion behaviour of metal brackets and wires in different electrolyte solutions.
    Kao CT; Huang TH
    Eur J Orthod; 2010 Oct; 32(5):555-60. PubMed ID: 20139132
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Laser surface alloying of 316L stainless steel coated with a bioactive hydroxyapatite-titanium oxide composite.
    Ghaith el-S; Hodgson S; Sharp M
    J Mater Sci Mater Med; 2015 Feb; 26(2):83. PubMed ID: 25636972
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A review of the application of anodization for the fabrication of nanotubes on metal implant surfaces.
    Minagar S; Berndt CC; Wang J; Ivanova E; Wen C
    Acta Biomater; 2012 Aug; 8(8):2875-88. PubMed ID: 22542885
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [Implantation of metals and plastics in surgery].
    Schuster J
    Med Klin; 1975 May; 70(19):841-6. PubMed ID: 1094254
    [No Abstract]   [Full Text] [Related]  

  • 54. Tissue reactions to metallic wear and corrosion products in human patients.
    Winter GD
    J Biomed Mater Res; 1974; 8(3):11-26. PubMed ID: 4455693
    [No Abstract]   [Full Text] [Related]  

  • 55. Implant acceptance in the musculoskeletal system.
    Dobson JL; Mathews RS; Stelling FH
    Clin Orthop Relat Res; 1970; 72():233-8. PubMed ID: 5459789
    [No Abstract]   [Full Text] [Related]  

  • 56. In vitro and in vivo metal ion release.
    Brown SA; Farnsworth LJ; Merritt K; Crowe TD
    J Biomed Mater Res; 1988 Apr; 22(4):321-38. PubMed ID: 3372552
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The electrochemical behavior of metallic implant materials as an indicator of their biocompatibility.
    Zitter H; Plenk H
    J Biomed Mater Res; 1987 Jul; 21(7):881-96. PubMed ID: 3611146
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Surface modifications to improve biocompatibility and mechanical properties of orthopedic implants].
    Thull R
    Orthopade; 2003 Jan; 32(1):51-9. PubMed ID: 12557086
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Is it safe for patients with metal implants to have iontophoresis treatment?
    Sinclair AVS; Garty FLR; Smith JR; Shipman AR
    Clin Exp Dermatol; 2023 Jul; 48(7):759-764. PubMed ID: 36857582
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Effects of fused-ring antibiotics on metallic corrosion.
    von Fraunhofer JA; Stidham SH
    J Biomed Eng; 1991 Sep; 13(5):424-8. PubMed ID: 1795511
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.