These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
112 related articles for article (PubMed ID: 9040994)
1. In vitro evaluation of wire integrity and ability to reprocess single-use sphincterotomes. Kozarek RA; Sumida SE; Raltz SL; Merriam LD; Irizarry DC Gastrointest Endosc; 1997 Feb; 45(2):117-21. PubMed ID: 9040994 [TBL] [Abstract][Full Text] [Related]
2. In vitro and in vivo evaluation of a reusable double-channel sphincterotome. Lee RM; Vida F; Kozarek RA; Raltz SL; Ball TJ; Patterson DJ; Brandabur JJ; Gluck M; Tomas A; Sumida SE; Irizarry D; Jane C Gastrointest Endosc; 1999 Apr; 49(4 Pt 1):477-82. PubMed ID: 10202062 [TBL] [Abstract][Full Text] [Related]
3. In vitro study and in vivo application of a reusable double-channel sphincterotome. Kozarek RA; Raltz SL; Brandabur JJ; Patterson DJ; Ball TJ; Gluck MG; Sumida SE; Roach SK; Drajpuch DE; Irizarry DL Endoscopy; 2001 May; 33(5):401-4. PubMed ID: 11396756 [TBL] [Abstract][Full Text] [Related]
4. Reuse of disposable sphincterotomes for diagnostic and therapeutic ERCP: a one-year prospective study. Kozarek RA; Raltz SL; Ball TJ; Patterson DJ; Brandabur JJ Gastrointest Endosc; 1999 Jan; 49(1):39-42. PubMed ID: 9869721 [TBL] [Abstract][Full Text] [Related]
5. How many times can you reuse a "single-use" sphincterotome? A prospective evaluation. Wilcox CM; Geels W; Baron TH Gastrointest Endosc; 1998 Jul; 48(1):58-60. PubMed ID: 9684666 [TBL] [Abstract][Full Text] [Related]
6. In vitro evaluation of integrity and sterilization of single-use argon beam plasma coagulation probes. Roach SK; Kozarek RA; Raltz SL; Sumida SE Am J Gastroenterol; 1999 Jan; 94(1):139-43. PubMed ID: 9934744 [TBL] [Abstract][Full Text] [Related]
7. Consistent improvement in sphincterotome orientation with manual grooming. Seibert DG; Matulis SR Gastrointest Endosc; 1995 Oct; 42(4):325-9. PubMed ID: 8536901 [TBL] [Abstract][Full Text] [Related]
8. Reliability, cost-effectiveness, and safety of reuse of ancillary devices for ERCP. Prat F; Spieler JF; Paci S; Pallier C; Fritsch J; Choury AD; Pelletier G; Raspaud S; Nordmann P; Buffet C Gastrointest Endosc; 2004 Aug; 60(2):246-52. PubMed ID: 15278053 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of single-use reprocessed laparoscopic instrument sterilization. Lopes Cde L; Graziano KU; Pinto Tde J Rev Lat Am Enfermagem; 2011; 19(2):370-7. PubMed ID: 21584385 [TBL] [Abstract][Full Text] [Related]
10. Inadequacy of manual cleaning for reprocessing single-use, triple-lumen sphinctertomes: simulated-use testing comparing manual with automated cleaning methods. Alfa MJ; Nemes R Am J Infect Control; 2003 Jun; 31(4):193-207. PubMed ID: 12806356 [TBL] [Abstract][Full Text] [Related]
12. Prospective multicenter study comparing a standard reusable sphincterotome with a disposable triple-lumen sphincterotome. Canard JM; Cellier C; Houcke P; Laurent J; Gorce D; Landi B Gastrointest Endosc; 2000 Jun; 51(6):704-7. PubMed ID: 10840304 [TBL] [Abstract][Full Text] [Related]
13. 5F sphincterotomes and 4F sphincterotomes are equivalent for the selective cannulation of the common bile duct. Abraham NS; Williams SP; Thompson K; Love JR; MacIntosh DG Gastrointest Endosc; 2006 Apr; 63(4):615-21. PubMed ID: 16564862 [TBL] [Abstract][Full Text] [Related]
15. Reusable biopsy forceps: a prospective evaluation of cleaning, function, adequacy of tissue specimen, and durability. Kozarek RA; Attia FM; Sumida SE; Raltz SL; Roach SK; Schembre DB; Brandabur JJ; Ball TJ; Gluck M; Jiranek GC; Patterson DJ; Bredfeldt JE; Gelfand M; McCormick SE; Drajpuch DB; Moran DK Gastrointest Endosc; 2001 Jun; 53(7):747-50. PubMed ID: 11375582 [TBL] [Abstract][Full Text] [Related]
16. Decontaminated single-use devices: an oxymoron that may be placing patients at risk for cross-contamination. Heeg P; Roth K; Reichl R; Cogdill CP; Bond WW Infect Control Hosp Epidemiol; 2001 Sep; 22(9):542-9. PubMed ID: 11732782 [TBL] [Abstract][Full Text] [Related]
17. Selective cannulation of the common bile duct: a prospective randomized trial comparing standard catheters with sphincterotomes. Cortas GA; Mehta SN; Abraham NS; Barkun AN Gastrointest Endosc; 1999 Dec; 50(6):775-9. PubMed ID: 10570335 [TBL] [Abstract][Full Text] [Related]
18. The effect of guidewires during electrosurgical sphincterotomy. Johlin FC; Tucker RD; Ferguson S Gastrointest Endosc; 1992; 38(5):536-40. PubMed ID: 1397906 [TBL] [Abstract][Full Text] [Related]
19. A prospective study of the repeated use of sterilized papillotomes and retrieval baskets for ERCP: quality and cost analysis. Cohen J; Haber GB; Kortan P; Dorais JA; Scheider DM; Cirocco M; Habib J Gastrointest Endosc; 1997 Feb; 45(2):122-7. PubMed ID: 9040995 [TBL] [Abstract][Full Text] [Related]
20. Repeated use of ablation catheters: a prospective study. Avitall B; Khan M; Krum D; Jazayeri M; Hare J J Am Coll Cardiol; 1993 Nov; 22(5):1367-72. PubMed ID: 8227793 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]