119 related articles for article (PubMed ID: 904593)
1. Dosimetric considerations of symmetric and asymmetric 60Co teletherapy split fields.
Wrede DE; Givens SB
Med Phys; 1977; 4(5):437-40. PubMed ID: 904593
[TBL] [Abstract][Full Text] [Related]
2. An intercomparison between two methods of obtaining percentage depth doses for irregular shaped fields and comparison of each method with experimental data for 60Co and 10 MV X rays.
Wrede D; Tai D; Edwards F; Coffey C; Schroader K
Br J Radiol; 1979 May; 52(617):398-404. PubMed ID: 109159
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric aspects of a rotating beam splitter used in tangential field breast treatment.
Jani SK; Pennington EC; Vigliotti AP; Hussey DH
Med Phys; 1987; 14(5):879-83. PubMed ID: 3683321
[TBL] [Abstract][Full Text] [Related]
4. Use of auxiliary collimating devices in the treatment for breast cancer with 60Co teletherapy units. I. Dosimetric considerations.
Grant W; Cundiff JH; Hanson WF
AJR Am J Roentgenol; 1976 Oct; 127(4):649-52. PubMed ID: 970539
[TBL] [Abstract][Full Text] [Related]
5. Dose measurement of cobalt-60 radiotherapy beams in treatment fields.
Memon SA; Cheema AA; Laghari NA; Mangi FH
J Ayub Med Coll Abbottabad; 2014; 26(3):279-82. PubMed ID: 25671926
[TBL] [Abstract][Full Text] [Related]
6. Analytical approach for depth dose calculations (60Co beams with fixed source-target distance).
Kanellitsas C; Fayos MS; Fayos JV
Radiology; 1975 Apr; 115(1):181-5. PubMed ID: 1118599
[TBL] [Abstract][Full Text] [Related]
7. Model for the calculation of output for elongated fields at nonstandard distances for a 25-MV betatron and for radiocobalt teletherapy units.
Starchman DE; Golden R; Puterbaugh MR; Loeffler RK
Med Phys; 1975; 2(6):333-5. PubMed ID: 811968
[TBL] [Abstract][Full Text] [Related]
8. Computer generation of cobalt-60 single beam dose distribution using an analytical beam model.
Jayaraman S
Strahlentherapie; 1981 Mar; 157(3):171-80. PubMed ID: 7210055
[TBL] [Abstract][Full Text] [Related]
9. Dosimetry of normally and obliquely incident cobalt-60 teletherapy beams.
Sabuwala HA
Strahlentherapie; 1979 Nov; 155(11):766-9. PubMed ID: 516098
[TBL] [Abstract][Full Text] [Related]
10. Mantle field dosimetry comparing 4 MV with cobalt 60.
Gray L; Prosnitz LR
Radiology; 1975 Aug; 116(02):429-32. PubMed ID: 807948
[TBL] [Abstract][Full Text] [Related]
11. Physical approach to depth dose distributions in a water phantom irradiated by a teleisotope photon beam.
Ahuja SD; Stroup SL; Bolin MG; Gibbs SJ
Med Phys; 1980; 7(2):120-6. PubMed ID: 7382915
[TBL] [Abstract][Full Text] [Related]
12. Tissue-air ratios for cobalt 60 therapy units.
Vatnitskij SM; Aalto PK; Rannikko SJ
Br J Radiol; 1983 May; 56(665):315-9. PubMed ID: 6850214
[TBL] [Abstract][Full Text] [Related]
13. A study of dose distribution patterns from cobalt-60 and Varian Clinac-4 beams.
Nair R; Kartha M
AJR Am J Roentgenol; 1978 Jan; 130(1):150-3. PubMed ID: 413401
[TBL] [Abstract][Full Text] [Related]
14. Dosimetric study of the narrow beams of 60Co teletherapy unit for stereotactic radiosurgery.
Singh RR; Ravindran P; Nizin PS; Ayyangar K
Med Dosim; 2000; 25(3):163-9. PubMed ID: 11025264
[TBL] [Abstract][Full Text] [Related]
15. Use of axiliary collimating devices in the treatment for breast cancer with 60Co teletherapy units. II. Dose to the skin.
Hanson WF; Grant W
AJR Am J Roentgenol; 1976 Oct; 127(4):653-7. PubMed ID: 970540
[TBL] [Abstract][Full Text] [Related]
16. The dosimetry of fixed, single source hemibody and total body irradiators.
Glasgow GP
Med Phys; 1982; 9(3):311-23. PubMed ID: 6810077
[TBL] [Abstract][Full Text] [Related]
17. Quality assurance control in the EORTC cooperative group of radiotherapy. 2. Dosimetric intercomparison.
Johansson KA; Horiot JC; Van Dam J; Lepinoy D; Sentenac I; Sernbo G
Radiother Oncol; 1986 Nov; 7(3):269-79. PubMed ID: 3809589
[TBL] [Abstract][Full Text] [Related]
18. Wedge factor dependence on depth and field size for various beam energies using symmetric and half-collimated asymmetric jaw settings.
Niroomand-Rad A; Haleem M; Rodgers J; Obcemea C
Med Phys; 1992; 19(6):1445-50. PubMed ID: 1461208
[TBL] [Abstract][Full Text] [Related]
19. Depth dose distributions in wedge fields of Co-60 beams.
Patomäki LK; Kiuru A
Strahlentherapie; 1974 Jun; 147(6):611-8. PubMed ID: 4439420
[No Abstract] [Full Text] [Related]
20. Dose in the buildup region outside the primary beam.
Horton JL
Med Phys; 1984; 11(3):331-4. PubMed ID: 6429500
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]