These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 9048359)

  • 1. Multiple-site fast exchange model for spin-lattice relaxation in the Fricke-gelatin dosimeter.
    Audet C; Schreiner LJ
    Med Phys; 1997 Feb; 24(2):201-9. PubMed ID: 9048359
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nuclear magnetic relaxation characterization of irradiated Fricke solution.
    Podgorsak MB; Schreiner LJ
    Med Phys; 1992; 19(1):87-95. PubMed ID: 1620063
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Chelator effect on ion diffusion in ferrous-sulfate-doped gelatin gel dosimeters as analyzed by MRI.
    Rae WI; Willemse CA; Lötter MG; Engelbrecht JS; Swarts JC
    Med Phys; 1996 Jan; 23(1):15-23. PubMed ID: 8700027
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A spin-spin relaxation rate investigation of the gelatin ferrous sulphate NMR dosimeter.
    Duzenli C; Sloboda R; Robinson D
    Phys Med Biol; 1994 Oct; 39(10):1577-92. PubMed ID: 15551532
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A least-squares error minimization approach in the determination of ferric ion diffusion coefficient of Fricke-infused dosimeter gels.
    Tseng YJ; Huang SC; Chu WC
    Med Phys; 2005 Apr; 32(4):1017-23. PubMed ID: 15895585
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Spatial resolution of magnetic resonance imaging Fricke-gel dosimetry is improved with a honeycomb phantom.
    Silva NA; Nicolucci P; Baffa O
    Med Phys; 2003 Jan; 30(1):17-20. PubMed ID: 12557973
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multifactorial study and kinetics of signal development in ferrous-methylthymol blue-gelatin gel dosimeters.
    Penev KI; Mequanint K
    Med Phys; 2017 May; 44(5):1948-1957. PubMed ID: 28273352
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multiexponential T2 relaxation in Fricke agarose gels: implications for NMR dosimetry.
    Luciani AM; Di Capua S; Guidoni L; Ragona R; Rosi A; Viti V
    Phys Med Biol; 1996 Mar; 41(3):509-21. PubMed ID: 8778829
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The verification of optimized 3D-dosage distributions with an MR Fricke gel].
    Scherer J; Bogner L; Herbst M; Müller-Broich A
    Strahlenther Onkol; 1997 Jan; 173(1):36-42. PubMed ID: 9082584
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Enhancing the longevity of three-dimensional dose in a diffusion-controlled Fricke gel dosimeter.
    Babu SE; Singh IR; Poornima CG; Ravindran BP
    J Cancer Res Ther; 2015; 11(3):580-5. PubMed ID: 26458585
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Fricke Gel Dosimeters].
    Maeyama T
    Igaku Butsuri; 2017; 37(2):99-106. PubMed ID: 29151472
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of three-dimensional radiation dose distributions using MRI.
    Prasad PV; Nalcioglu O; Rabbani B
    Radiat Res; 1991 Oct; 128(1):1-13. PubMed ID: 1924718
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dose-response curves for Fricke-infused agarose gels as obtained by nuclear magnetic resonance.
    Schulz RJ; deGuzman AF; Nguyen DB; Gore JC
    Phys Med Biol; 1990 Dec; 35(12):1611-22. PubMed ID: 2284332
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere.
    Fong PM; Keil DC; Does MD; Gore JC
    Phys Med Biol; 2001 Dec; 46(12):3105-13. PubMed ID: 11768494
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of saccharide additives on response of ferrous-agarose-xylenol orange radiotherapy gel dosimeters.
    Healy BJ; Zahmatkesh MH; Nitschke KN; Baldock C
    Med Phys; 2003 Sep; 30(9):2282-91. PubMed ID: 14528948
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dose-response curve slope improvement and result reproducibility of ferrous-sulphate-doped gels analysed by NMR imaging.
    Gambarini G; Arrigoni S; Cantone MC; Molho N; Facchielli L; Sichirollo AE
    Phys Med Biol; 1994 Apr; 39(4):703-17. PubMed ID: 15552079
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dose-response characteristics of a ferrous-sulphate-doped gelatin system for determining radiation absorbed dose distributions by magnetic resonance imaging (Fe MRI).
    Hazle JD; Hefner L; Nyerick CE; Wilson L; Boyer AL
    Phys Med Biol; 1991 Aug; 36(8):1117-25. PubMed ID: 1924545
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter.
    Kelly RG; Jordan KJ; Battista JJ
    Med Phys; 1998 Sep; 25(9):1741-50. PubMed ID: 9775382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optical imaging of dose distributions in Fricke gels.
    Viti V; d'Errico F; Pacilio M; Luciani AM; Palma A; Grande S; Ranghiasci C; Adorante N; Guidoni L; Rosi A; Ranade M; de Pasquale F; Barone P; Sebastiani G
    Radiat Prot Dosimetry; 2006; 120(1-4):148-50. PubMed ID: 16614085
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Temperature dependence of polymer-gel dosimeter nuclear magnetic resonance response.
    Spevacek V; Novotny J; Dvorak P; Novotny J; Vymazal J; Cechak T
    Med Phys; 2001 Nov; 28(11):2370-8. PubMed ID: 11764045
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.