These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 9050480)

  • 21. Safer trocar insertion for closed laparoscopic access: ex vivo assessment of an improved Veress needle.
    Nevler A; Har-Zahav G; Rosin D; Gutman M
    Surg Endosc; 2016 Feb; 30(2):779-782. PubMed ID: 26123325
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A randomized comparison of Verres needle and direct trocar insertion for laparoscopy.
    Byron JW; Markenson G; Miyazawa K
    Surg Gynecol Obstet; 1993 Sep; 177(3):259-62. PubMed ID: 8356499
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Preliminary pneumoperitoneum facilitates transgastric access into the peritoneal cavity for natural orifice transluminal endoscopic surgery: a pilot study in a live porcine model.
    Ko CW; Shin EJ; Buscaglia JM; Clarke JO; Magno P; Giday SA; Chung SS; Cotton PB; Gostout CJ; Hawes RH; Pasricha PJ; Kalloo AN; Kantsevoy SV
    Endoscopy; 2007 Oct; 39(10):849-53. PubMed ID: 17968798
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Safe Veress Needle Intraperitoneal Placement and Safer Laparoscopic Entry.
    Vilos G; Vilos A; Jacob GP; Abu-Rafea B; Ternamian A
    J Minim Invasive Gynecol; 2018; 25(7):1137. PubMed ID: 29425722
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Modification of Veress needle insertion.
    Genovese ML
    Surg Laparosc Endosc; 1998 Apr; 8(2):160-1. PubMed ID: 9566577
    [No Abstract]   [Full Text] [Related]  

  • 26. Establishment of primary port without insertion of a sharp trocar.
    Kaali SG
    J Am Assoc Gynecol Laparosc; 1998 May; 5(2):193-5. PubMed ID: 9564071
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Open laparoscopic approach--an alterative to the Veress needle. Experiences after 1,000 laparoscopies].
    Rumstadt B; Werthmann K; Jentschura D; Stark E
    Chirurg; 1996 Sep; 67(9):949-51. PubMed ID: 8991778
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Laparoscopic needle introducer.
    Valtchev KL
    J Am Assoc Gynecol Laparosc; 2001 Nov; 8(4):579-82. PubMed ID: 11677340
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of transperitoneal laparoscopic access techniques: Optiview visualizing trocar and Veress needle.
    Marcovich R; Del Terzo MA; Wolf JS
    J Endourol; 2000 Mar; 14(2):175-9. PubMed ID: 10772511
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A 5-mm open-entry technique achieves safe, single-step, cosmetic laparoscopic entry.
    Keltz MD; Lang J; Berin I
    JSLS; 2007; 11(2):195-7. PubMed ID: 17761079
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A new insufflation needle with a special optical system for use in laparoscopic procedures.
    Riek S; Bachmann KH; Gaiselmann T; Hoernstein F; Marzusch K
    Obstet Gynecol; 1994 Sep; 84(3):476-8. PubMed ID: 8058252
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Safe laparoscopic entry guided by Veress needle CO2 insufflation pressure.
    Vilos GA; Vilos AG
    J Am Assoc Gynecol Laparosc; 2003 Aug; 10(3):415-20. PubMed ID: 14567827
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Vacuum-supported endoscopic access.
    Klemm B; Salm R
    Endosc Surg Allied Technol; 1995 Feb; 3(1):58-62. PubMed ID: 7757442
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Evaluation of tests performed to confirm the position of the Veress needle for creation of pneumoperitoneum in selected patients: a prospective clinical trial].
    Azevedo OC; Azevedo JL; Sorbello AA; Miguel GP; Wilson Junior JL; Godoy AC
    Acta Cir Bras; 2006; 21(6):385-91. PubMed ID: 17160250
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Laparoscopic access with a visualizing trocar.
    Wolf JS
    Tech Urol; 1997; 3(1):34-7. PubMed ID: 9170223
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The all-seeing needle instead of the Veress needle in pediatric urologic laparoscopy.
    Silay MS; Tepeler A; Sancaktutar AA; Kilincaslan H; Altay B; Erdem MR; Hatipoglu NK; Akcay M; Akman T; Armagan A
    J Endourol; 2013 Nov; 27(11):1376-80. PubMed ID: 23560687
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A method of closing laparoscopy port incisions using a modified Veress needle.
    Goldrath MH; Phillips E
    J Am Assoc Gynecol Laparosc; 1996 Feb; 3(2):287-90. PubMed ID: 9050642
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Rationale and intended use for the Veress needle: a translation of the original descriptive article.
    Bridgewater FH; Mouton WG
    Surg Laparosc Endosc Percutan Tech; 1999 Aug; 9(4):241-3. PubMed ID: 10871168
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A randomized, prospective study comparing the use of the missile trocar and the pyramidal trocar for laparoscopy access.
    Tansatit T; Wisawasukmongchol W; Bunyavejchevin S
    J Med Assoc Thai; 2006 Jul; 89(7):941-7. PubMed ID: 16881424
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Latif's point: A new point for Veress needle insertion for pneumoperitoneum in difficult laparoscopy.
    Abd Ellatif ME; Ghnnam WM; Abbas A; Basheer M; Dawoud I; Ellaithy R
    Asian J Endosc Surg; 2018 May; 11(2):133-137. PubMed ID: 28856845
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.