122 related articles for article (PubMed ID: 9056104)
1. Analytical evaluation of the CK-MB mass assay on the Technicon Immuno 1 system.
Lévesque A; Letellier M; Grant A
Clin Biochem; 1997 Feb; 30(1):11-6. PubMed ID: 9056104
[TBL] [Abstract][Full Text] [Related]
2. Analytical evaluation of the testosterone assay on the Bayer Immuno 1 system.
Lévesque A; Letellier M; Swirski C; Lee C; Grant A
Clin Biochem; 1998 Feb; 31(1):23-8. PubMed ID: 9559220
[TBL] [Abstract][Full Text] [Related]
3. Higher CK-MB mass values in heparin plasma than in serum measured with the Abbott AxSYM system.
Hedberg P; Melkko T; Valkama J; Puukka M
Clin Chem Lab Med; 2001 Sep; 39(9):872-4. PubMed ID: 11601688
[No Abstract] [Full Text] [Related]
4. Automated quantification of creatine kinase MB isoenzyme in serum by radial partition immunoassay, with use of the Stratus analyzer.
Chapelle JP; el Allaf M
Clin Chem; 1990 Jan; 36(1):99-101. PubMed ID: 2404644
[TBL] [Abstract][Full Text] [Related]
5. Creatine kinase MB measured by fluorometric enzyme immunoassay and immunochemiluminescence.
McBride JH; Rodgerson DO; Ota MK; Maruya M; McEveney S
Ann Clin Lab Sci; 1991; 21(4):284-90. PubMed ID: 1859167
[TBL] [Abstract][Full Text] [Related]
6. Clinical laboratory investigation of the Sanofi ACCESS CK-MB procedure and comparison to electrophoresis and Abbott IMx.
Mao GD; Adeli K; Eisenbrey AB; Artiss JD
Am J Clin Pathol; 1996 Jul; 106(1):112-7. PubMed ID: 8701919
[TBL] [Abstract][Full Text] [Related]
7. Analytical performance of time-resolved fluorometry-based Innotrac Aio! cardiac marker immunoassays.
Hedberg P; Valkama J; Puukka M
Scand J Clin Lab Invest; 2003; 63(1):55-64. PubMed ID: 12729070
[TBL] [Abstract][Full Text] [Related]
8. Quantifying the MB isoenzyme of creatine kinase with the Abbott "IMx" immunoassay analyzer.
Brandt DR; Gates RC; Eng KK; Forsythe CM; Korom GK; Nitro AS; Koffler PA; Ogunro EA
Clin Chem; 1990 Feb; 36(2):375-8. PubMed ID: 2406043
[TBL] [Abstract][Full Text] [Related]
9. Analytical evaluation of methods for serum creatine kinase-MB. Electrophoresis, immunoinhibition and solid phase separation.
Gadsden RH; Papadea CN; Cate JC
Ann Clin Lab Sci; 1994; 24(2):110-20. PubMed ID: 8203820
[TBL] [Abstract][Full Text] [Related]
10. [Evaluation of CK-MB determination technique by immuno-enzymolfluorometry with Vidas (bioMérieux)].
Ayed SB; Boukezia N; Foglietti MJ; Bernard M
Ann Biol Clin (Paris); 1996; 54(3-4):145-9. PubMed ID: 8881360
[TBL] [Abstract][Full Text] [Related]
11. Stratus automated creatine kinase-MB assay evaluated: identification and elimination of falsely increased results associated with a high-molecular-mass form of alkaline phosphatase.
Butch AW; Goodnow TT; Brown WS; McClellan A; Kessler G; Scott MG
Clin Chem; 1989 Oct; 35(10):2048-53. PubMed ID: 2676240
[TBL] [Abstract][Full Text] [Related]
12. Immunochemiluminometric assay of creatine kinase MB with a monoclonal antibody to the MB isoenzyme.
Piran U; Kohn DW; Uretsky LS; Bernier D; Barlow EH; Niswander CA; Stastny M
Clin Chem; 1987 Sep; 33(9):1517-20. PubMed ID: 3304711
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the chemiluminescence immunoassays for the measurement of troponin I, myoglobin and CK-MB using the IMMULITE system in comparison to other measuring systems.
Lestin M; Hergert M; Lestin HG; Brinker C; Storm H; Kuhrt E; Kuhrt B; Lambrecht HG; Kühnel W
Clin Lab; 2002; 48(3-4):211-21. PubMed ID: 11934224
[TBL] [Abstract][Full Text] [Related]
14. CK-MB mass test in ischemic myocardial injury. Comparison of two tests: BioMerieux Vidas and sanofi access immunoassays.
Poirey S; Polge A; Bertinchant JP; Bancel E; Boyer JC; Fabbro-Peray P; de Bornier BM; Ledermann B; Bonnier M; Bali JP
J Clin Lab Anal; 2000; 14(2):43-7. PubMed ID: 10683612
[TBL] [Abstract][Full Text] [Related]
15. Cardiac troponin-T immunoassay for diagnosis of acute myocardial infarction.
Wu AH; Valdes R; Apple FS; Gornet T; Stone MA; Mayfield-Stokes S; Ingersoll-Stroubos AM; Wiler B
Clin Chem; 1994 Jun; 40(6):900-7. PubMed ID: 8087984
[TBL] [Abstract][Full Text] [Related]
16. A sensitive bioluminescent immunoinhibition test for CK-B subunit activity and a CK-MB specific ELISA compared: correlation with agarose electrophoresis and influence of CK-isoenzyme profile on results.
Gorus F; Claessens V; Goubert P; Laureys M
Clin Chem; 1988 Jul; 34(7):1474-8. PubMed ID: 3390922
[TBL] [Abstract][Full Text] [Related]
17. Human heart-type cytoplasmic fatty acid-binding protein (H-FABP) for the diagnosis of acute myocardial infarction. Clinical evaluation of H-FABP in comparison with myoglobin and creatine kinase isoenzyme MB.
Okamoto F; Sohmiya K; Ohkaru Y; Kawamura K; Asayama K; Kimura H; Nishimura S; Ishii H; Sunahara N; Tanaka T
Clin Chem Lab Med; 2000 Mar; 38(3):231-8. PubMed ID: 10905760
[TBL] [Abstract][Full Text] [Related]
18. Clinical and analytical evaluation of two immunoassays for direct measurement of creatine kinase MB with monoclonal anti-CK-MB antibodies.
Apple F; Preese L; Bennett R; Fredrickson A
Clin Chem; 1988 Nov; 34(11):2364-7. PubMed ID: 3052931
[TBL] [Abstract][Full Text] [Related]
19. Immunoenzymetric assay for creatine kinase MB with subunit-specific monoclonal antibodies compared with an immunochemical method and electrophoresis.
Chan DW; Taylor E; Frye R; Blitzer RL
Clin Chem; 1985 Mar; 31(3):465-9. PubMed ID: 3882277
[TBL] [Abstract][Full Text] [Related]
20. AACC creatine kinase MB (CK-MB) standardization material used as manufacturer's working calibrator is unable to harmonize CK-MB results between two commercial immunoassays.
Panteghini M; Pagani F
Clin Chem; 2004 Sep; 50(9):1711-2. PubMed ID: 15331520
[No Abstract] [Full Text] [Related]
[Next] [New Search]