60 related articles for article (PubMed ID: 9056754)

  • 1. Study of the interference of haemolysis in the determination of creatinine in the Technicon DAX-72 (Bayer).
    Guix P; Parera M; Fuentespina E; García A; Coll R
    Eur J Clin Chem Clin Biochem; 1997 Feb; 35(2):115-6. PubMed ID: 9056754
    [No Abstract]   [Full Text] [Related]  

  • 2. Evaluation of the Bayer microalbumin/creatinine urinalysis dipstick.
    Wilde HM; Banks D; Larsen CL; Connors G; Wallace D; Lyon ME
    Clin Chim Acta; 2008 Jul; 393(2):110-3. PubMed ID: 18407839
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of a new diagnostic kit for the enzymatic determination of creatinine.
    Lanser A; Blijenberg BG; Leijnse B
    J Clin Chem Clin Biochem; 1979 Oct; 17(10):633-8. PubMed ID: 501291
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Creatinine in erythrocytes. Possible effect on plasma creatinine].
    Hagemann P
    Schweiz Med Wochenschr; 1976 Oct; 106(44):1514-5. PubMed ID: 1006275
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Enzymatic procedures for determining creatinine].
    Wisser H; Knoll E
    Internist (Berl); 1987 Feb; 28(2):123-7. PubMed ID: 3330065
    [No Abstract]   [Full Text] [Related]  

  • 6. Effect of various concentrations of flucytosine on the accuracy of serum creatinine determinations.
    Souney PF; Mariani G
    Am J Hosp Pharm; 1985 Mar; 42(3):621-2. PubMed ID: 3985027
    [No Abstract]   [Full Text] [Related]  

  • 7. Hemoglobin interference with the BMD total bilirubin assay in the Hitachi 705 analyzer, and its relation to the hemolytic index.
    Karkoski DJ
    Clin Chem; 1985 May; 31(5):791. PubMed ID: 3987019
    [No Abstract]   [Full Text] [Related]  

  • 8. Potential interfering substances on Falcor-600 and Dax-48 analytical systems.
    Fitó M; Biosca C; Hernandez JM; Galimany R
    Eur J Clin Chem Clin Biochem; 1997 Oct; 35(10):787-92. PubMed ID: 9368798
    [TBL] [Abstract][Full Text] [Related]  

  • 9. EMIT dau: methadone false positive with creatinine interference.
    Fucci N
    Forensic Sci Int; 2005 Feb; 148(1):81. PubMed ID: 15607595
    [No Abstract]   [Full Text] [Related]  

  • 10. Do enzymatic and Jaffé creatinine assays produce comparable results for pre and post dialysis specimens from patients with chronic renal failure?
    Rumbelow BD; Peake MJ; Ehrhardt V
    Clin Lab; 2000; 46(11-12):589-90. PubMed ID: 11109507
    [No Abstract]   [Full Text] [Related]  

  • 11. Mechanism of interference by haemolysis in the cardiac troponin T immunoassay.
    Sodi R; Darn SM; Davison AS; Stott A; Shenkin A
    Ann Clin Biochem; 2006 Jan; 43(Pt 1):49-56. PubMed ID: 16390609
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The determination of free and protein-bound haemoglobin in plasma using a combination of HPLC and absorption spectrometry.
    Wood WG; Kress M; Meissner D; Hanke R; Reinauer H
    Clin Lab; 2001; 47(5-6):279-88. PubMed ID: 11405606
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Discrepancy between visual and spectrophotometric assessment of sample haemolysis.
    Hawkins R
    Ann Clin Biochem; 2002 Sep; 39(Pt 5):521-2. PubMed ID: 12227862
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High levels of serum soluble CD27 correlated with renal dysfunction.
    Nakatsuji T
    Clin Exp Med; 2003 Feb; 2(4):192-6. PubMed ID: 12624711
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of in vitro hemolysis on equine serum chemical values.
    Dorner JL; Hoffmann WE; Lock TF
    Am J Vet Res; 1981 Sep; 42(9):1519-22. PubMed ID: 7325459
    [No Abstract]   [Full Text] [Related]  

  • 16. The impact of hemolysis on Ortho-Clinical Diagnostic's ECi and Roche's elecsys immunoassay systems.
    Snyder JA; Rogers MW; King MS; Phillips JC; Chapman JF; Hammett-Stabler CA
    Clin Chim Acta; 2004 Oct; 348(1-2):181-7. PubMed ID: 15369753
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Haemolysis as an influence and interference factor in clinical chemistry.
    Guder WG
    J Clin Chem Clin Biochem; 1986 Feb; 24(2):125-6. PubMed ID: 3711796
    [No Abstract]   [Full Text] [Related]  

  • 18. Evidence that guanidines and some related compounds cause haemolysis in chronic uraemia.
    Giovannetti S; Cioni L; Balestri PL; Biagnini M
    Clin Sci; 1968 Feb; 34(1):141-8. PubMed ID: 5640680
    [No Abstract]   [Full Text] [Related]  

  • 19. Interference of plasmatic reduced glutathione and hemolysis on glutathione disulfide levels in human blood.
    Giustarini D; Dalle-Donne I; Colombo R; Milzani A; Rossi R
    Free Radic Res; 2004 Oct; 38(10):1101-6. PubMed ID: 15512798
    [TBL] [Abstract][Full Text] [Related]  

  • 20. C(Tr)/C(Cr) ratio in pancreatic disease.
    Malesci A; Bonato C; Bersani M
    Gastroenterology; 1982 Mar; 82(3):603. PubMed ID: 10336331
    [No Abstract]   [Full Text] [Related]  