These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Biodegradable self-reinforced polyglycolide screws and rods in the fixation of displaced malleolar fractures in the elderly. A comparison with metallic implants. Kankare J; Partio EK; Hirvensalo E; Böstman O; Rokkanen P Ann Chir Gynaecol; 1996; 85(3):263-70. PubMed ID: 8950450 [TBL] [Abstract][Full Text] [Related]
3. Redisplacement after ankle osteosynthesis with absorbable implants. Pelto-Vasenius K; Hirvensalo E; Vasenius J; Partio EK; Böstman O; Rokkanen P Arch Orthop Trauma Surg; 1998; 117(3):159-62. PubMed ID: 9521522 [TBL] [Abstract][Full Text] [Related]
4. Bioabsorbable fixation in the treatment of proximal tibial osteotomies and fractures. A clinical study. Tuompo P; Partio E; Rokkanen P Ann Chir Gynaecol; 1999; 88(1):66-72. PubMed ID: 10230686 [TBL] [Abstract][Full Text] [Related]
5. Totally absorbable fixation in the treatment of fractures of the distal femoral epiphyses. A prospective clinical study. Partio EK; Tuompo P; Hirvensalo E; Böstman O; Rokkanen P Arch Orthop Trauma Surg; 1997; 116(4):213-6. PubMed ID: 9128774 [TBL] [Abstract][Full Text] [Related]
6. Treatment of Lateral Tibial Condylar Fractures Using Bioactive, Bioresorbable Forged Composites of Raw Particulate Unsintered Hydroxyapatite/Poly-L-Lactide Screws. Kuroyanagi G; Yoshihara H; Yamamoto N; Suzuki H; Yamada K; Yoshida Y; Otsuka T; Takada N Orthopedics; 2018 May; 41(3):e365-e368. PubMed ID: 29570761 [TBL] [Abstract][Full Text] [Related]
7. [Immobilization and early mobilization of malleolar fractures after osteosynthesis with resorbable bone screws]. Partio EK Unfallchirurgie; 1992 Oct; 18(5):304-10. PubMed ID: 1441001 [TBL] [Abstract][Full Text] [Related]
8. Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws: a three- to nine-year follow-up study. Böstman OM J Bone Joint Surg Br; 1998 Mar; 80(2):333-8. PubMed ID: 9546472 [TBL] [Abstract][Full Text] [Related]
10. Self-reinforced absorbable screws in the fixation of displaced ankle fractures: a prospective clinical study of 152 patients. Partio EK; Böstman O; Hirvensalo E; Vainionpää S; Vihtonen K; Pätiälä H; Törmälä P; Rokkanen P J Orthop Trauma; 1992; 6(2):209-15. PubMed ID: 1318361 [TBL] [Abstract][Full Text] [Related]
11. Absorbable fixation of femoral head fractures. A prospective study of six cases. Jukkala-Partio K; Partio EK; Hirvensalo E; Rokkanen P Ann Chir Gynaecol; 1998; 87(1):44-8. PubMed ID: 9598230 [TBL] [Abstract][Full Text] [Related]
12. [Treatment of fracture involved articular surface with absorbable screws and rods]. Qi JH; Zhu BL; Yin DZ Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2003 Nov; 17(6):453-5. PubMed ID: 14663940 [TBL] [Abstract][Full Text] [Related]
13. [Absorbable SR-PGA implant in orthopaedics: preliminary results of treatment of fractures]. Liu Y; Rong G Zhonghua Wai Ke Za Zhi; 1995 Jan; 33(1):51-3. PubMed ID: 7774448 [TBL] [Abstract][Full Text] [Related]
14. [Resorbable rods and screws for fixation of ankle fractures. A randomized clinical prospective study]. Springer MA; van Binsbergen EA; Patka P; Bakker FC; Haarman HJ Unfallchirurg; 1998 May; 101(5):377-81. PubMed ID: 9629050 [TBL] [Abstract][Full Text] [Related]
15. [Absorbable rods and screws: a new method of fixation for fractures of the olecranon]. Partio EK; Hirvensalo E; Böstman O; Pätiälä H; Vainionpää S; Vihtonen R; Helevirta P; Törmälä P; Rokkanen P Int Orthop; 1992; 16(3):250-4. PubMed ID: 1428337 [TBL] [Abstract][Full Text] [Related]
16. Operative treatment of displaced intra-articular fractures of the calcaneus using absorbable internal fixation: a prospective study of twenty-five fractures. Kankare J J Orthop Trauma; 1998 Aug; 12(6):413-9. PubMed ID: 9715449 [TBL] [Abstract][Full Text] [Related]
17. The role of arthroscopy in the assessment and treatment of tibial plateau fractures. Fowble CD; Zimmer JW; Schepsis AA Arthroscopy; 1993; 9(5):584-90. PubMed ID: 8280333 [TBL] [Abstract][Full Text] [Related]
18. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study. Horn C; Döbele S; Vester H; Schäffler A; Lucke M; Stöckle U Injury; 2011 Oct; 42(10):1031-7. PubMed ID: 21663909 [TBL] [Abstract][Full Text] [Related]
19. [Computerized tomography assisted follow-up of arthroscopic implantation of hydroxylapatite implants in fractures of the head of the tibial. Preliminary results of CT-controlled quantitative evaluation of healing and foreign body reaction to calcium hydroxyapatite implants]. Liebig T; Schedel H; Kodadadyan Z; Ricke J; Hoffmann R; Haas N; Felix R Rontgenpraxis; 1996 Jun; 49(6):141-4. PubMed ID: 8766916 [No Abstract] [Full Text] [Related]
20. Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Takeuchi R; Ishikawa H; Kumagai K; Yamaguchi Y; Chiba N; Akamatsu Y; Saito T Arthroscopy; 2012 Jan; 28(1):85-94. PubMed ID: 21982387 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]