These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 9063922)

  • 1. [In vitro evaluation of hemolytic effects with use of infusion pumps with finger peristaltic action of blood pumping].
    Lerche D; Merk A
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1996 Nov; 31(9):568-72. PubMed ID: 9063922
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Changes in red blood cell integrity related to infusion pumps: a comparison of three different pump mechanisms.
    Frey B; Eber S; Weiss M
    Pediatr Crit Care Med; 2003 Oct; 4(4):465-70. PubMed ID: 14525644
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Quality of washed autologous erythrocytes from drainage-suction pumps].
    Bauermann E; Shin M; Möhlmann ML; Kadar JG; Linde I
    Anaesthesiol Reanim; 1999; 24(4):101-8. PubMed ID: 10528416
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Increased hemolysis from saline pre-washing RBCs or centrifugal pumps in neonatal ECMO.
    Masalunga C; Cruz M; Porter B; Roseff S; Chui B; Mainali E
    J Perinatol; 2007 Jun; 27(6):380-4. PubMed ID: 17443201
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative assessment of haemolysis secondary to modern infusion pumps.
    Poder TG; Boileau JC; Lafrenière R; Thibault L; Carrier N; de Grandmont MJ; Beauregard P
    Vox Sang; 2017 Apr; 112(3):201-209. PubMed ID: 28198026
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Alterations in red blood cell volume and hemoglobin concentration, viscoelastic properties, and mechanical fragility caused by continuous flow pumping in calves.
    Yokoyama N; Sakota D; Nagaoka E; Takatani S
    Artif Organs; 2011 Aug; 35(8):791-9. PubMed ID: 21843294
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Haemolysis following rapid experimental red blood cell transfusion--an evaluation of two infusion pumps.
    Hansen TG; Sprogøe-Jakobsen U; Pedersen CM; Olsen KS; Kristensen SR
    Acta Anaesthesiol Scand; 1998 Jan; 42(1):57-62. PubMed ID: 9527746
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical damage of red blood cells by rotary blood pumps: selective destruction of aged red blood cells and subhemolytic trauma.
    Sakota D; Sakamoto R; Sobajima H; Yokoyama N; Waguri S; Ohuchi K; Takatani S
    Artif Organs; 2008 Oct; 32(10):785-91. PubMed ID: 18959667
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of modern infusion pumps on RBC quality.
    Hadjesfandiari N; Serrano K; Levin E; Johal P; Feenstra S; Shih AW; Devine DV
    Transfusion; 2022 Apr; 62(4):797-808. PubMed ID: 35213738
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of intravenous delivery systems on infused red blood cells.
    Gibson JS; Leff RD; Roberts RJ
    Am J Hosp Pharm; 1984 Mar; 41(3):468-72. PubMed ID: 6702849
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multi-institutional randomized control study of haemolysis in stored red cell units prepared manually or by an automated system.
    McAteer MJ; Dumont LJ; Cancelas J; Rugg N; Vassallo R; Whitley P; Graminske S; Friedman K
    Vox Sang; 2010 Jul; 99(1):34-43. PubMed ID: 20202178
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Red cell damage after pumping by two infusion control devices (Arcomed VP 7000 and IVAC 572).
    Parfitt HS; Davies SV; Tighe P; Ewings P
    Transfus Med; 2007 Aug; 17(4):290-5. PubMed ID: 17680955
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Glucose depletion enhances sensitivity to shear stress-induced mechanical damage in red blood cells by rotary blood pumps.
    Sakota D; Sakamoto R; Yokoyama N; Kobayashi M; Takatani S
    Artif Organs; 2009 Sep; 33(9):733-9. PubMed ID: 19775265
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Trauma to erythrocytes induced by long term in vitro pumping using a roller pump.
    Ding MJ; Xu SW; Zhang J; Wang Q; Chang Y; Chen F; Zeng YJ
    Cell Biol Int; 2007 Aug; 31(8):763-7. PubMed ID: 17344073
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative assessment of infusion pump-mediated haemolysis in feline packed red blood cell transfusions.
    Blasi-Brugué C; Sanchez IM; Ferreira RR; de Matos AJ; Ruiz de Gopegui R
    J Feline Med Surg; 2021 Dec; 23(12):1149-1154. PubMed ID: 33719675
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Effect of whole blood preparation and leukocyte filtration on storage of erythrocyte concentrates over 42 days].
    Müller-Steinhardt M; Janetzko K; Kirchner H; Klüter H
    Beitr Infusionsther Transfusionsmed; 1997; 34():53-7. PubMed ID: 9417353
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Effects of an infusion pump with peristaltic mechanism of action on various blood components in vitro].
    Wagner B; Wüst T; Beeser HP
    Beitr Infusionsther; 1992; 30():454-9. PubMed ID: 1284759
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prestorage leucoreduction improves several in vitro red cell storage parameters following gamma irradiation.
    Wagner SJ; Myrup AC
    Transfus Med; 2006 Aug; 16(4):261-5. PubMed ID: 16879154
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vitro quality of red blood cells (RBCs) collected by multicomponent apheresis compared to manually collected RBCs during 49 days of storage.
    Picker SM; Radojska SM; Gathof BS
    Transfusion; 2007 Apr; 47(4):687-96. PubMed ID: 17381628
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hemolysis risk after packed red blood cells transfusion with infusion pumps.
    Wilson AMMM; Peterlini MAS; Pedreira MDLG
    Rev Lat Am Enfermagem; 2018 Oct; 26():e3053. PubMed ID: 30328976
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.