These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 9065907)

  • 1. Susceptibility, field inhomogeneity, and chemical shift-corrected NMR microscopy: application to the human finger in vivo.
    Weis J; Görke U; Kimmich R
    Magn Reson Imaging; 1996; 14(10):1165-75. PubMed ID: 9065907
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 1H-spectroscopic imaging with read gradient during acquisition in inhomogeneous fields: analysis, measurement strategy, and data processing.
    Weis J; Ericsson A; Hemmingsson A
    MAGMA; 1997 Sep; 5(3):201-12. PubMed ID: 9351024
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Field inhomogeneity correction and data processing for spectroscopic imaging.
    Maudsley AA; Hilal SK
    Magn Reson Med; 1985 Jun; 2(3):218-33. PubMed ID: 3831691
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Correcting heat-induced chemical shift distortions in proton resonance frequency-shift thermometry.
    Gaur P; Partanen A; Werner B; Ghanouni P; Bitton R; Butts Pauly K; Grissom WA
    Magn Reson Med; 2016 Jul; 76(1):172-82. PubMed ID: 26301458
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid in vivo proton shimming.
    Schneider E; Glover G
    Magn Reson Med; 1991 Apr; 18(2):335-47. PubMed ID: 2046515
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A three-dimensional NMR imaging scheme utilizing doubly resonant gradient coils.
    Codd SL; Mallett MJ; Halse MR; Strange JH; Vennart W; Van Doorn T
    J Magn Reson B; 1996 Dec; 113(3):214-21. PubMed ID: 8995842
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On the utility of spectroscopic imaging as a tool for generating geometrically accurate MR images and parameter maps in the presence of field inhomogeneities and chemical shift effects.
    Bakker CJ; de Leeuw H; van de Maat GH; van Gorp JS; Bouwman JG; Seevinck PR
    Magn Reson Imaging; 2013 Jan; 31(1):86-95. PubMed ID: 22898694
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Chemical shift artifact-free microscopy: spectroscopic microimaging of the human skin.
    Weis J; Ericsson A; Hemmingsson A
    Magn Reson Med; 1999 May; 41(5):904-8. PubMed ID: 10332872
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Correction of chemical-shift artifacts in 19F imaging of PFOB: a robust signed magnitude method.
    Lee HK; Nalcioglu O; Buxton RB
    Magn Reson Med; 1992 Feb; 23(2):254-63. PubMed ID: 1549040
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tailored spiral in-out spectral-spatial water suppression pulses for magnetic resonance spectroscopic imaging.
    Ma J; Wismans C; Cao Z; Klomp DWJ; Wijnen JP; Grissom WA
    Magn Reson Med; 2018 Jan; 79(1):31-40. PubMed ID: 28370494
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correction for EPI distortions using multi-echo gradient-echo imaging.
    Chen NK; Wyrwicz AM
    Magn Reson Med; 1999 Jun; 41(6):1206-13. PubMed ID: 10371453
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of and correction for eddy current artifacts in echo planar diffusion imaging.
    Jezzard P; Barnett AS; Pierpaoli C
    Magn Reson Med; 1998 May; 39(5):801-12. PubMed ID: 9581612
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI.
    Chen NK; Oshio K; Panych LP
    Neuroimage; 2006 Jun; 31(2):609-22. PubMed ID: 16480898
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Echo-planar diffusion spectroscopic imaging.
    Bito Y; Hirata S; Nabeshima T; Yamamoto E
    Magn Reson Med; 1995 Jan; 33(1):69-73. PubMed ID: 7891537
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gradient reversal technique and its applications to chemical-shift-related NMR imaging.
    Park HW; Kim DJ; Cho ZH
    Magn Reson Med; 1987 Jun; 4(6):526-36. PubMed ID: 3613953
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan.
    Schmithorst VJ; Dardzinski BJ; Holland SK
    IEEE Trans Med Imaging; 2001 Jun; 20(6):535-9. PubMed ID: 11437113
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Chemical-shift artifact correction scheme using echo-time encoding technique.
    Cho ZH; Nalcioglu O; Park HW; Ra JB; Hilal SK
    Magn Reson Med; 1985 Jun; 2(3):253-61. PubMed ID: 3831694
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Removal of local field gradient artifacts in T2*-weighted images at high fields by gradient-echo slice excitation profile imaging.
    Yang QX; Williams GD; Demeure RJ; Mosher TJ; Smith MB
    Magn Reson Med; 1998 Mar; 39(3):402-9. PubMed ID: 9498596
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Equilibrium signal intensity mapping, an MRI method for fast mapping of longitudinal relaxation rates and for image enhancement.
    Surányi P; Kiss P; Ruzsics B; Brott BC; Simor T; Elgavish GA
    Magn Reson Imaging; 2007 Jun; 25(5):641-51. PubMed ID: 17540275
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diffusion-weighted line-scan echo-planar spectroscopic imaging technique to reduce motion artifacts in metabolite diffusion imaging.
    Bito Y; Hirata K; Ebisu T; Kawai Y; Otake Y; Hirata S; Shirai T; Soutome Y; Ochi H; Yamamoto E; Umeda M; Higuchi T; Tanaka C
    Magn Reson Med Sci; 2015; 14(1):43-50. PubMed ID: 25345411
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.