These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
132 related articles for article (PubMed ID: 9068538)
21. A randomized controlled trial of efficacy and ST change following use of the Welch-Allyn MRL PIC biphasic waveform versus damped sine monophasic waveform for external DC cardioversion. Ambler JJ; Deakin CD Resuscitation; 2006 Nov; 71(2):146-51. PubMed ID: 16987583 [TBL] [Abstract][Full Text] [Related]
22. Skin burns from electrosurgical current. Pearce JA; Geddes LA; Van Vleet JF; Foster K; Allen J Med Instrum; 1983; 17(3):225-31. PubMed ID: 6877129 [TBL] [Abstract][Full Text] [Related]
23. [Impact of electrical shock waveform and paddle positions on efficacy of direct current cardioversion for atrial fibrillation]. Stanaitiene G; Babarskiene RM Medicina (Kaunas); 2008; 44(9):665-72. PubMed ID: 18971603 [TBL] [Abstract][Full Text] [Related]
24. Transthoracic cardioversion of atrial fibrillation and flutter: standard techniques and new advances. Kerber RE Am J Cardiol; 1996 Oct; 78(8A):22-6. PubMed ID: 8903272 [TBL] [Abstract][Full Text] [Related]
25. Comparative efficacy of monophasic and biphasic waveforms for transthoracic cardioversion of atrial fibrillation and atrial flutter. Gurevitz OT; Ammash NM; Malouf JF; Chandrasekaran K; Rosales AG; Ballman KV; Hammill SC; White RD; Gersh BJ; Friedman PA Am Heart J; 2005 Feb; 149(2):316-21. PubMed ID: 15846271 [TBL] [Abstract][Full Text] [Related]
26. Biphasic versus monophasic shock waveform for conversion of atrial fibrillation. Rho RW; Page RL Card Electrophysiol Rev; 2003 Sep; 7(3):290-1. PubMed ID: 14739730 [TBL] [Abstract][Full Text] [Related]
27. Selective dysfunction of ventricular electrode-endocardial junction following DC cardioversion in a patient with a dual chamber pacemaker. Das G; Staffanson DB Pacing Clin Electrophysiol; 1997 Feb; 20(2 Pt 1):364-5. PubMed ID: 9058877 [TBL] [Abstract][Full Text] [Related]
28. Unexpected burns under skin electrodes. Orpin JA Can Med Assoc J; 1982 Dec; 127(11):1106. PubMed ID: 7139459 [No Abstract] [Full Text] [Related]
29. Low energy internal cardioversion of atrial fibrillation resistant to transthoracic shocks. Sopher SM; Murgatroyd FD; Slade AK; Blankoff I; Rowland E; Ward DE; Camm AJ Heart; 1996 Jun; 75(6):635-8. PubMed ID: 8697172 [TBL] [Abstract][Full Text] [Related]
30. Early epidermal changes in heat- and electrically injured pig skin. I. A light microscopic study. Thomsen HK; Danielsen L; Nielsen O; Aalund O; Nielsen KG; Karlsmark T; Genefke IK Forensic Sci Int; 1981; 17(2):133-43. PubMed ID: 6165657 [TBL] [Abstract][Full Text] [Related]
31. Current density imaging and electrically induced skin burns under surface electrodes. Patriciu A; Yoshida K; Struijk JJ; DeMonte TP; Joy ML; Stødkilde-Jørgensen H IEEE Trans Biomed Eng; 2005 Dec; 52(12):2024-31. PubMed ID: 16366226 [TBL] [Abstract][Full Text] [Related]
32. Estimation of current density distribution under electrodes for external defibrillation. Krasteva VT; Papazov SP Biomed Eng Online; 2002 Dec; 1():7. PubMed ID: 12537593 [TBL] [Abstract][Full Text] [Related]
33. Port site electrosurgical (diathermy) burns during surgical laparoscopy. Willson PD; van der Walt JD; Moxon D; Rogers J Surg Endosc; 1997 Jun; 11(6):653-4. PubMed ID: 9171127 [TBL] [Abstract][Full Text] [Related]
34. Randomised comparison of electrode positions for cardioversion of atrial fibrillation. Mathew TP; Moore A; McIntyre M; Harbinson MT; Campbell NP; Adgey AA; Dalzell GW Heart; 1999 Jun; 81(6):576-9. PubMed ID: 10336913 [TBL] [Abstract][Full Text] [Related]