95 related articles for article (PubMed ID: 9069325)
1. Validity of the interval method for the determination of the anisotropy factor of high dose rate 192Ir sources.
Cho SH; Muller-Runkel R
Int J Radiat Oncol Biol Phys; 1997 Jan; 37(2):483-7. PubMed ID: 9069325
[TBL] [Abstract][Full Text] [Related]
2. On the dosimetric accuracy of a Sievert integration model in the proximity of 192Ir HDR sources.
Pantelis E; Baltas D; Dardoufas K; Karaiskos P; Papagiannis P; Rosaki-Mavrouli H; Sakelliou L
Int J Radiat Oncol Biol Phys; 2002 Jul; 53(4):1071-84. PubMed ID: 12095576
[TBL] [Abstract][Full Text] [Related]
3. Application of the Monte Carlo integration (MCI) method for calculation of the anisotropy of 192Ir brachytherapy sources.
Baltas D; Giannouli S; Garbi A; Diakonos F; Geramani K; Ioannidis GT; Tsalpatouros A; Uzunoglu N; Kolotas C; Zamboglou N
Phys Med Biol; 1998 Jun; 43(6):1783-801. PubMed ID: 9651040
[TBL] [Abstract][Full Text] [Related]
4. Dose rate calculations around 192Ir brachytherapy sources using a Sievert integration model.
Karaiskos P; Angelopoulos A; Baras P; Rozaki-Mavrouli H; Sandilos P; Vlachos L; Sakelliou L
Phys Med Biol; 2000 Feb; 45(2):383-98. PubMed ID: 10701510
[TBL] [Abstract][Full Text] [Related]
5. Dosimetry comparison of 192Ir sources.
Papagiannis P; Angelopoulos A; Pantelis E; Sakelliou L; Baltas D; Karaiskos P; Sandilos P; Vlachos L
Med Phys; 2002 Oct; 29(10):2239-46. PubMed ID: 12408297
[TBL] [Abstract][Full Text] [Related]
6. Study of encapsulated 170Tm sources for their potential use in brachytherapy.
Ballester F; Granero D; Perez-Calatayud J; Venselaar JL; Rivard MJ
Med Phys; 2010 Apr; 37(4):1629-37. PubMed ID: 20443484
[TBL] [Abstract][Full Text] [Related]
7. Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus 192Ir sources.
Ballester F; Puchades V; Lluch JL; Serrano-Andrés MA; Limami Y; Pérez-Calatayud J; Casal E
Med Phys; 2001 Dec; 28(12):2586-91. PubMed ID: 11797964
[TBL] [Abstract][Full Text] [Related]
8. A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.
Lymperopoulou G; Papagiannis P; Angelopoulos A; Karaiskos P; Georgiou E; Baltas D
Med Phys; 2006 Dec; 33(12):4583-9. PubMed ID: 17278810
[TBL] [Abstract][Full Text] [Related]
9. Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source.
Angelopoulos A; Baras P; Sakelliou L; Karaiskos P; Sandilos P
Med Phys; 2000 Nov; 27(11):2521-7. PubMed ID: 11128304
[TBL] [Abstract][Full Text] [Related]
10. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources.
Bannon EA; Yang Y; Rivard MJ
Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369
[TBL] [Abstract][Full Text] [Related]
11. A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy.
Wang R; Li XA
Med Phys; 2000 Nov; 27(11):2528-35. PubMed ID: 11128305
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.
Ho Than MT; Munro Iii JJ; Medich DC
J Appl Clin Med Phys; 2015 May; 16(3):5270. PubMed ID: 26103489
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo dosimetry of the IRAsource high dose rate (192)Ir brachytherapy source.
Sarabiasl A; Ayoobian N; Jabbari I; Poorbaygi H; Javanshir MR
Australas Phys Eng Sci Med; 2016 Jun; 39(2):413-22. PubMed ID: 26906341
[TBL] [Abstract][Full Text] [Related]
14. Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192Ir sources.
Williamson JF; Li Z
Med Phys; 1995 Jun; 22(6):809-19. PubMed ID: 7565372
[TBL] [Abstract][Full Text] [Related]
15. Comments on 'determination of the dose characteristics in the near area of a new type of 192Ir-HDR afterloading source with a pinpoint ionization chamber'.
Ballester F
Phys Med Biol; 2003 Mar; 48(5):L23-5; author reply L25-6. PubMed ID: 12696806
[No Abstract] [Full Text] [Related]
16. EGSnrc Monte Carlo calculated dosimetry parameters for 192Ir and 169Yb brachytherapy sources.
Taylor RE; Rogers DW
Med Phys; 2008 Nov; 35(11):4933-44. PubMed ID: 19070227
[TBL] [Abstract][Full Text] [Related]
17. Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors.
Zilio VO; Joneja OP; Popowski Y; Rosenfeld A; Chawla R
Med Phys; 2006 Jun; 33(6):1532-9. PubMed ID: 16872060
[TBL] [Abstract][Full Text] [Related]
18. Determination of the tissue attenuation factor along two major axes of a high dose rate (HDR) 192Ir source.
Cho SH; Muller-Runkel R; Hanson WF
Med Phys; 1999 Aug; 26(8):1492-7. PubMed ID: 10501048
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of scatter contribution and distance error by iterative methods for strength determination of HDR 192Ir brachytherapy source.
Kumar S; Srinivasan P; Sharma SD; Subbaiah KV; Mayya YS
Med Dosim; 2010; 35(3):230-7. PubMed ID: 19931038
[TBL] [Abstract][Full Text] [Related]
20. Attenuation of intracavitary applicators in 192Ir-HDR brachytherapy.
Ye SJ; Brezovich IA; Shen S; Duan J; Popple RA; Pareek PN
Med Phys; 2004 Jul; 31(7):2097-106. PubMed ID: 15305463
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]