286 related articles for article (PubMed ID: 9070522)
21. [10-year actuarial analysis of a cohort of 156 total hip prostheses of a cemented polished aluminum/polyethylene alloy].
Le Mouel S; Allain J; Goutallier D
Rev Chir Orthop Reparatrice Appar Mot; 1998 Jul; 84(4):338-45. PubMed ID: 9775034
[TBL] [Abstract][Full Text] [Related]
22. The rates of wear of X3 highly cross-linked polyethylene at five years when coupled with a 36 mm diameter ceramic femoral head in young patients.
Selvarajah E; Hooper G; Grabowski K; Frampton C; Woodfield TB; Inglis G
Bone Joint J; 2015 Nov; 97-B(11):1470-4. PubMed ID: 26530647
[TBL] [Abstract][Full Text] [Related]
23. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty.
Sochart DH
Clin Orthop Relat Res; 1999 Jun; (363):135-50. PubMed ID: 10379315
[TBL] [Abstract][Full Text] [Related]
24. Polyethylene wear in prosthetic hips with loose components.
Kesteris U; Hardinge K; Ilchmann T; Wingstrand H
J Arthroplasty; 2003 Jan; 18(1):10-5. PubMed ID: 12555176
[TBL] [Abstract][Full Text] [Related]
25. Total hip arthroplasty with cement and use of a collared matte-finish femoral component: nineteen to twenty-year follow-up.
Callaghan JJ; Liu SS; Firestone DE; Yehyawi TM; Goetz DD; Sullivan J; Vittetoe DA; O'Rourke MR; Johnston RC
J Bone Joint Surg Am; 2008 Feb; 90(2):299-306. PubMed ID: 18245589
[TBL] [Abstract][Full Text] [Related]
26. Size of the femoral head and acetabular revision in total hip-replacement arthroplasty.
Morrey BF; Ilstrup D
J Bone Joint Surg Am; 1989 Jan; 71(1):50-5. PubMed ID: 2913003
[TBL] [Abstract][Full Text] [Related]
27. How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study.
Pourzal R; Knowlton CB; Hall DJ; Laurent MP; Urban RM; Wimmer MA
Clin Orthop Relat Res; 2016 Aug; 474(8):1867-75. PubMed ID: 26891896
[TBL] [Abstract][Full Text] [Related]
28. [Wear and Roughness of Bearing Surface in Retrieved Polyethylene Bicon-Plus Cups].
Ranuša M; Gallo J; Hobza M; Vrbka M; Nečas D; Hartl M
Acta Chir Orthop Traumatol Cech; 2017; 84(3):159-167. PubMed ID: 28809634
[TBL] [Abstract][Full Text] [Related]
29. Charnley total hip arthroplasty with use of improved techniques of cementing. The results after a minimum of fifteen years of follow-up.
Madey SM; Callaghan JJ; Olejniczak JP; Goetz DD; Johnston RC
J Bone Joint Surg Am; 1997 Jan; 79(1):53-64. PubMed ID: 9010186
[TBL] [Abstract][Full Text] [Related]
30. Surface roughness of ceramic femoral heads after in vivo transfer of metal: correlation to polyethylene wear.
Kim YH; Ritchie A; Hardaker C
J Bone Joint Surg Am; 2005 Mar; 87(3):577-82. PubMed ID: 15741625
[TBL] [Abstract][Full Text] [Related]
31. Postmortem study of femoral osteolysis associated with metal-on-metal articulation in total hip replacement: an analysis of nine cases.
Huber M; Reinisch G; Zenz P; Zweymüller K; Lintner F
J Bone Joint Surg Am; 2010 Jul; 92(8):1720-31. PubMed ID: 20660235
[TBL] [Abstract][Full Text] [Related]
32. Comparison of polyethylene wear in machined versus molded polyethylene.
Bankston AB; Keating EM; Ranawat C; Faris PM; Ritter MA
Clin Orthop Relat Res; 1995 Aug; (317):37-43. PubMed ID: 7671494
[TBL] [Abstract][Full Text] [Related]
33. Backside volumetric change in the polyethylene of uncemented acetabular components.
Krieg AH; Speth BM; Ochsner PE
J Bone Joint Surg Br; 2009 Aug; 91(8):1037-43. PubMed ID: 19651830
[TBL] [Abstract][Full Text] [Related]
34. Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application.
Devane PA; Bourne RB; Rorabeck CH; MacDonald S; Robinson EJ
Clin Orthop Relat Res; 1995 Oct; (319):317-26. PubMed ID: 7554645
[TBL] [Abstract][Full Text] [Related]
35. Polyethylene wear in cemented metal-backed acetabular cups.
Cates HE; Faris PM; Keating EM; Ritter MA
J Bone Joint Surg Br; 1993 Mar; 75(2):249-53. PubMed ID: 8444945
[TBL] [Abstract][Full Text] [Related]
36. Retrieved Unicompartmental Implants with Full PE Tibial Components: The Effects of Knee Alignment and Polyethylene Thickness on Creep and Wear.
Hernigou P; Poignard A; Filippini P; Zilber S
Open Orthop J; 2008 Apr; 2():51-6. PubMed ID: 19590591
[TBL] [Abstract][Full Text] [Related]
37. Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator.
Hermida JC; Bergula A; Chen P; Colwell CW; D'Lima DD
J Bone Joint Surg Am; 2003 Dec; 85(12):2325-31. PubMed ID: 14668501
[TBL] [Abstract][Full Text] [Related]
38. Total hip arthroplasty with cement in patients less than twenty years old. Long-term results.
Torchia ME; Klassen RA; Bianco AJ
J Bone Joint Surg Am; 1996 Jul; 78(7):995-1003. PubMed ID: 8698735
[TBL] [Abstract][Full Text] [Related]
39. The association between rates of wear in retrieved acetabular components and the radius of the femoral head.
Hall RM; Siney P; Unsworth A; Wroblewski BM
Proc Inst Mech Eng H; 1998; 212(5):321-6. PubMed ID: 9803151
[TBL] [Abstract][Full Text] [Related]
40. The porous-coated anatomic total hip prosthesis: failure of the metal-backed acetabular component.
Astion DJ; Saluan P; Stulberg BN; Rimnac CM; Li S
J Bone Joint Surg Am; 1996 May; 78(5):755-66. PubMed ID: 8642033
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]