These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 9075008)

  • 1. The deformation of small diameter solid tibial nails with unreamed intramedullary insertion.
    Krettek C; Mannss J; Könemann B; Miclau T; Schandelmaier P; Tscherne H
    J Biomech; 1997 Apr; 30(4):391-4. PubMed ID: 9075008
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Deformation of femoral nails with intramedullary insertion.
    Krettek C; Mannss J; Miclau T; Schandelmaier P; Linnemann I; Tscherne H
    J Orthop Res; 1998 Sep; 16(5):572-5. PubMed ID: 9820280
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Analysis of implantation-induced nail deformation and roentgen morphometric studies as the principle for an aiming device for distal interlocking nailing without roentgen image intensification].
    Krettek C; Könemann B; Mannss J; Schandelmaier P; Schmidt U; Tscherne H
    Unfallchirurg; 1996 Sep; 99(9):671-8. PubMed ID: 9005579
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro and in vivo radiomorphometric analyses of distal screw hole position of the solid tibial nail following insertion.
    Krettek C; Könemann B; Miclau T; Schlandelmaier P; Blauth M; Tscherne H
    Clin Biomech (Bristol, Avon); 1997 Apr; 12(3):198-200. PubMed ID: 11415695
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The mechanical effect of blocking screws ("Poller screws") in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails.
    Krettek C; Miclau T; Schandelmaier P; Stephan C; Möhlmann U; Tscherne H
    J Orthop Trauma; 1999 Nov; 13(8):550-3. PubMed ID: 10714781
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.
    Weninger P; Schueller M; Jamek M; Stanzl-Tschegg S; Redl H; Tschegg EK
    Clin Biomech (Bristol, Avon); 2009 May; 24(4):379-84. PubMed ID: 19231049
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study.
    Horn J; Linke B; Höntzsch D; Gueorguiev B; Schwieger K
    Injury; 2009 Jul; 40(7):767-71. PubMed ID: 19450799
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Micromotion at the fracture site after tibial nailing with four unreamed small-diameter nails--a biomechanical study using a distal tibia fracture model.
    Schüller M; Weninger P; Tschegg E; Jamek M; Redl H; Stanzl-Tschegg S
    J Trauma; 2009 May; 66(5):1391-7. PubMed ID: 19430244
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new technique for the distal locking of solid AO unreamed tibial nails.
    Krettek C; Könemann B; Miclau T; Schandelmaier P; Blauth M; Tscherne H
    J Orthop Trauma; 1997 Aug; 11(6):446-51. PubMed ID: 9314154
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new mechanical aiming device for the placement of distal interlocking screws in femoral nails.
    Krettek C; Könemann B; Miclau T; Kölbli R; Machreich T; Kromm A; Tscherne H
    Arch Orthop Trauma Surg; 1998; 117(3):147-52. PubMed ID: 9521519
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intramedullary nailing for tibial shaft fractures in adults.
    Duan X; Al-Qwbani M; Zeng Y; Zhang W; Xiang Z
    Cochrane Database Syst Rev; 2012 Jan; 1():CD008241. PubMed ID: 22258982
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Distal locking of femoral nails. Mathematical analysis of the appropriate targeting range.
    Moor BK; Ehlinger M; Arlettaz Y
    Orthop Traumatol Surg Res; 2012 Feb; 98(1):85-9. PubMed ID: 22264565
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparison of the torsional performance of stainless steel and titanium alloy tibial intramedullary nails: a clinically relevant approach.
    Aitchison GA; Johnstone AJ; Shepherd DE; Watson MA
    Biomed Mater Eng; 2004; 14(3):235-40. PubMed ID: 15299235
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [A comparison of a fluoroscopy-free mechanical targeting system and a free-hand technic for the placement of distal interlocking screws of tibial nails].
    Krettek C; Könemann B; Farouk O; Kromm A; Schandelamier P; Tscherne H
    Chirurg; 1997 Nov; 68(11):1194-201. PubMed ID: 9518215
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [A new roentgen ray-free aiming technique for distal locking screw boring of the unreamed tibial nail].
    Krettek C; Könemann B; Farouk O; Kromm A; Tscherne H
    Langenbecks Arch Chir Suppl Kongressbd; 1996; 113():947-50. PubMed ID: 9102034
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
    Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
    J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
    Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical comparison of tibial nail stability in a proximal third fracture: do screw quantity and locked, interlocking screws make a difference?
    Freeman AL; Craig MR; Schmidt AH
    J Orthop Trauma; 2011 Jun; 25(6):333-9. PubMed ID: 21577068
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The risk of iatrogenic injury to anterior tibial artery variations during tibial nail distal interlocking.
    Fanter NJ; Inouye SE; Beiser CW
    J Orthop Surg (Hong Kong); 2017 Jan; 25(1):2309499016684471. PubMed ID: 28176597
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.