These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

214 related articles for article (PubMed ID: 9075034)

  • 41. [Failure of obstetric epidural analgesia and its causes].
    Fernández Martínez MA; Ros Mora J; Villalonga Morales A
    Rev Esp Anestesiol Reanim; 2000; 47(6):256-65. PubMed ID: 10981442
    [TBL] [Abstract][Full Text] [Related]  

  • 42. A systematic review of randomized controlled trials that evaluate strategies to avoid epidural vein cannulation during obstetric epidural catheter placement.
    Mhyre JM; Greenfield ML; Tsen LC; Polley LS
    Anesth Analg; 2009 Apr; 108(4):1232-42. PubMed ID: 19299793
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Soft catheters reduce the risk of intravascular cannulation during epidural block--a retrospective analysis of 1,117 cases in a medical center.
    Shih CK; Wang FY; Shieh CF; Huang JM; Lu IC; Wu LC; Lu DV
    Kaohsiung J Med Sci; 2012 Jul; 28(7):373-6. PubMed ID: 22726899
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Catheter failure rates and time course with epidural versus combined spinal-epidural analgesia in labor.
    Groden J; Gonzalez-Fiol A; Aaronson J; Sachs A; Smiley R
    Int J Obstet Anesth; 2016 May; 26():4-7. PubMed ID: 26971650
    [TBL] [Abstract][Full Text] [Related]  

  • 45. A comparison of multiport and uniport epidural catheters in laboring patients.
    D'Angelo R; Foss ML; Livesay CH
    Anesth Analg; 1997 Jun; 84(6):1276-9. PubMed ID: 9174306
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A retrospective effectiveness study of loss of resistance to air or saline for identification of the epidural space.
    Segal S; Arendt KW
    Anesth Analg; 2010 Feb; 110(2):558-63. PubMed ID: 19955501
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Labor epidural analgesia without an intravascular "test dose".
    Norris MC; Fogel ST; Dalman H; Borrenpohl S; Hoppe W; Riley A
    Anesthesiology; 1998 Jun; 88(6):1495-501. PubMed ID: 9637642
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Predictive model for the inadequate labor epidural analgesia: an outcome of the prospective observational study at university women's hospital.
    Muppuri R; Gupta D; Agarwal S; Soskin V
    Middle East J Anaesthesiol; 2012 Jun; 21(5):719-24. PubMed ID: 23265036
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Lateral recumbent head-down posture for epidural catheter insertion reduces intravascular injection.
    Bahar M; Chanimov M; Cohen ML; Friedland M; Grinshpon Y; Brenner R; Shul I; Datsky R; Sherman DJ
    Can J Anaesth; 2001 Jan; 48(1):48-53. PubMed ID: 11212049
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Use of a 23-gauge continuous spinal catheter for labor analgesia: a case series.
    Tao W; Nguyen AP; Ogunnaike BO; Craig MG
    Int J Obstet Anesth; 2011 Oct; 20(4):351-4. PubMed ID: 21907561
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The use of a sound-enabled device to measure pressure during insertion of an epidural catheter in women in labour.
    Lechner TJ; van Wijk MG; Jongenelis AA; Rybak M; van Niekerk J; Langenberg CJ
    Anaesthesia; 2011 Jul; 66(7):568-73. PubMed ID: 21539528
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Repeat epidural analgesia and unilateral block.
    Withington DE; Weeks SK
    Can J Anaesth; 1994 Jul; 41(7):568-71. PubMed ID: 8087902
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Comparison of single, end-holed and multi-orifice extradural catheters when used for continuous infusion of local anaesthetic during labour.
    Dickson MA; Moores C; McClure JH
    Br J Anaesth; 1997 Sep; 79(3):297-300. PubMed ID: 9389844
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Accidental venous and dural puncture during epidural analgesia in obese parturients (BMI > 40 kg/m2): three different body positions during insertion.
    Chanimov M; Evron S; Haitov Z; Stolero S; Cohen ML; Friedland M; Shul I; Bahar M
    J Clin Anesth; 2010 Dec; 22(8):614-8. PubMed ID: 21109134
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Prospective examination of epidural catheter insertion.
    D'Angelo R; Berkebile BL; Gerancher JC
    Anesthesiology; 1996 Jan; 84(1):88-93. PubMed ID: 8572359
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Ultrasound guided L5-S1 placement of labor epidural does not improve dermatomal block in parturients.
    Malik T; Malas O; Thompson A
    Int J Obstet Anesth; 2019 May; 38():52-58. PubMed ID: 30551813
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Combined Spinal Epidural Technique for Labor Analgesia Does Not Delay Recognition of Epidural Catheter Failures: A Single-center Retrospective Cohort Survival Analysis.
    Booth JM; Pan JC; Ross VH; Russell GB; Harris LC; Pan PH
    Anesthesiology; 2016 Sep; 125(3):516-24. PubMed ID: 27380107
    [TBL] [Abstract][Full Text] [Related]  

  • 58. The effects of needle bevel orientation during epidural catheter insertion in laboring parturients.
    Richardson MG; Wissler RN
    Anesth Analg; 1999 Feb; 88(2):352-6. PubMed ID: 9972755
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The optimal distance that a multiorifice epidural catheter should be threaded into the epidural space.
    Beilin Y; Bernstein HH; Zucker-Pinchoff B
    Anesth Analg; 1995 Aug; 81(2):301-4. PubMed ID: 7618719
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Another knotted epidural catheter.
    Macfarlane J; Paech MJ
    Anaesth Intensive Care; 2002 Apr; 30(2):240-3. PubMed ID: 12002939
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.