41. [Failure of obstetric epidural analgesia and its causes]. Fernández Martínez MA; Ros Mora J; Villalonga Morales A Rev Esp Anestesiol Reanim; 2000; 47(6):256-65. PubMed ID: 10981442 [TBL] [Abstract][Full Text] [Related]
42. A systematic review of randomized controlled trials that evaluate strategies to avoid epidural vein cannulation during obstetric epidural catheter placement. Mhyre JM; Greenfield ML; Tsen LC; Polley LS Anesth Analg; 2009 Apr; 108(4):1232-42. PubMed ID: 19299793 [TBL] [Abstract][Full Text] [Related]
43. Soft catheters reduce the risk of intravascular cannulation during epidural block--a retrospective analysis of 1,117 cases in a medical center. Shih CK; Wang FY; Shieh CF; Huang JM; Lu IC; Wu LC; Lu DV Kaohsiung J Med Sci; 2012 Jul; 28(7):373-6. PubMed ID: 22726899 [TBL] [Abstract][Full Text] [Related]
44. Catheter failure rates and time course with epidural versus combined spinal-epidural analgesia in labor. Groden J; Gonzalez-Fiol A; Aaronson J; Sachs A; Smiley R Int J Obstet Anesth; 2016 May; 26():4-7. PubMed ID: 26971650 [TBL] [Abstract][Full Text] [Related]
45. A comparison of multiport and uniport epidural catheters in laboring patients. D'Angelo R; Foss ML; Livesay CH Anesth Analg; 1997 Jun; 84(6):1276-9. PubMed ID: 9174306 [TBL] [Abstract][Full Text] [Related]
46. A retrospective effectiveness study of loss of resistance to air or saline for identification of the epidural space. Segal S; Arendt KW Anesth Analg; 2010 Feb; 110(2):558-63. PubMed ID: 19955501 [TBL] [Abstract][Full Text] [Related]
48. Predictive model for the inadequate labor epidural analgesia: an outcome of the prospective observational study at university women's hospital. Muppuri R; Gupta D; Agarwal S; Soskin V Middle East J Anaesthesiol; 2012 Jun; 21(5):719-24. PubMed ID: 23265036 [TBL] [Abstract][Full Text] [Related]
49. Lateral recumbent head-down posture for epidural catheter insertion reduces intravascular injection. Bahar M; Chanimov M; Cohen ML; Friedland M; Grinshpon Y; Brenner R; Shul I; Datsky R; Sherman DJ Can J Anaesth; 2001 Jan; 48(1):48-53. PubMed ID: 11212049 [TBL] [Abstract][Full Text] [Related]
50. Use of a 23-gauge continuous spinal catheter for labor analgesia: a case series. Tao W; Nguyen AP; Ogunnaike BO; Craig MG Int J Obstet Anesth; 2011 Oct; 20(4):351-4. PubMed ID: 21907561 [TBL] [Abstract][Full Text] [Related]
51. The use of a sound-enabled device to measure pressure during insertion of an epidural catheter in women in labour. Lechner TJ; van Wijk MG; Jongenelis AA; Rybak M; van Niekerk J; Langenberg CJ Anaesthesia; 2011 Jul; 66(7):568-73. PubMed ID: 21539528 [TBL] [Abstract][Full Text] [Related]
52. Repeat epidural analgesia and unilateral block. Withington DE; Weeks SK Can J Anaesth; 1994 Jul; 41(7):568-71. PubMed ID: 8087902 [TBL] [Abstract][Full Text] [Related]
53. Comparison of single, end-holed and multi-orifice extradural catheters when used for continuous infusion of local anaesthetic during labour. Dickson MA; Moores C; McClure JH Br J Anaesth; 1997 Sep; 79(3):297-300. PubMed ID: 9389844 [TBL] [Abstract][Full Text] [Related]
54. Accidental venous and dural puncture during epidural analgesia in obese parturients (BMI > 40 kg/m2): three different body positions during insertion. Chanimov M; Evron S; Haitov Z; Stolero S; Cohen ML; Friedland M; Shul I; Bahar M J Clin Anesth; 2010 Dec; 22(8):614-8. PubMed ID: 21109134 [TBL] [Abstract][Full Text] [Related]
56. Ultrasound guided L5-S1 placement of labor epidural does not improve dermatomal block in parturients. Malik T; Malas O; Thompson A Int J Obstet Anesth; 2019 May; 38():52-58. PubMed ID: 30551813 [TBL] [Abstract][Full Text] [Related]
57. Combined Spinal Epidural Technique for Labor Analgesia Does Not Delay Recognition of Epidural Catheter Failures: A Single-center Retrospective Cohort Survival Analysis. Booth JM; Pan JC; Ross VH; Russell GB; Harris LC; Pan PH Anesthesiology; 2016 Sep; 125(3):516-24. PubMed ID: 27380107 [TBL] [Abstract][Full Text] [Related]
58. The effects of needle bevel orientation during epidural catheter insertion in laboring parturients. Richardson MG; Wissler RN Anesth Analg; 1999 Feb; 88(2):352-6. PubMed ID: 9972755 [TBL] [Abstract][Full Text] [Related]
59. The optimal distance that a multiorifice epidural catheter should be threaded into the epidural space. Beilin Y; Bernstein HH; Zucker-Pinchoff B Anesth Analg; 1995 Aug; 81(2):301-4. PubMed ID: 7618719 [TBL] [Abstract][Full Text] [Related]