118 related articles for article (PubMed ID: 9086299)
1. Discrepancies between thyrotropin (TSH) measurement by four sensitive immunometric assays.
Rasmussen AK; Hilsted L; Perrild H; Christiansen E; Siersbaek-Nielsen K; Feldt-Rasmussen U
Clin Chim Acta; 1997 Mar; 259(1-2):117-28. PubMed ID: 9086299
[TBL] [Abstract][Full Text] [Related]
2. Comparison of the analytical and clinical performances of three thyrotropin immunoassay kits.
Minebois-Villégas A; Rohmer V; Rachédi F; Berrut G; Boux de Casson-Raimbeau F; Wion-Barbot N; Bigorgne JC; Jallet P
Ann Biol Clin (Paris); 1995; 53(7-8):413-8. PubMed ID: 8597312
[TBL] [Abstract][Full Text] [Related]
3. [Recent developments of measurements for pituitary-thyroid hormones: evaluation of five immunometric assay methods (RI and non RI methods].
Hashimoto T; Nishibu M; Kawai K; Horita H; Ayukawa T; Matsubara F
Rinsho Byori; 1991 Sep; 39(9):913-9. PubMed ID: 1942564
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of the Abbott IMx ultrasensitive II hTSH immunometric assay in three European centres: a comparison with established commercial immunometric assays for thyrotropin.
Wood WG; Bruns U; Eber O; Langsteger W; Bounaud JY; Bounaud MP
Eur J Clin Chem Clin Biochem; 1996 Feb; 34(2):151-8. PubMed ID: 8833649
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of a new chemiluminescence technique for human thyrotropin (BeriLux hTSH): diagnostic value of five immunometric assay methods.
Hashimoto T; Matsubara F; Nishibu M; Kawai K
Eur J Clin Chem Clin Biochem; 1991 Nov; 29(11):753-7. PubMed ID: 1782283
[TBL] [Abstract][Full Text] [Related]
6. An evaluation of six solid-phase thyrotropin (TSH) kits.
Wood WG; Waller D; Hantke U
J Clin Chem Clin Biochem; 1985 Aug; 23(8):461-71. PubMed ID: 4056662
[TBL] [Abstract][Full Text] [Related]
7. Persistent problems with the specificity of immunometric TSH assays.
Laurberg P
Thyroid; 1993; 3(4):279-83. PubMed ID: 8118223
[TBL] [Abstract][Full Text] [Related]
8. Technical and clinical performance of six sensitive immunoradiometric assays of thyrotropin in serum.
Rodriguez-Espinosa J; Mora-Brugues J; Ordoñez-Llanos J; Cortes-Rius M; Queralto-Companyo JM; Gonzalez-Sastre F
Clin Chem; 1987 Aug; 33(8):1439-45. PubMed ID: 3111753
[TBL] [Abstract][Full Text] [Related]
9. Interlaboratory/intermethod differences in functional sensitivity of immunometric assays of thyrotropin (TSH) and impact on reliability of measurement of subnormal concentrations of TSH.
Spencer CA; Takeuchi M; Kazarosyan M; MacKenzie F; Beckett GJ; Wilkinson E
Clin Chem; 1995 Mar; 41(3):367-74. PubMed ID: 7882510
[TBL] [Abstract][Full Text] [Related]
10. The effects of common matrices for assay standards on performance of 'ultra sensitive' immunometric assays for TSH. Report of a joint WHO/IFCC collaborative study.
Gaines-Das RE; Brettschneider H; Bristow AF
Clin Chim Acta; 1991 Dec; 203(2-3):S5-15. PubMed ID: 1777974
[TBL] [Abstract][Full Text] [Related]
11. Clinical usefulness and limitations of serum thyrotropin measurement by 'ultrasensitive' methods. Comparisons of five kits.
Carayon P; Martino E; Bartalena L; Grasso L; Mammoli C; Costagliola S; Pinchera A
Horm Res; 1987; 26(1-4):105-17. PubMed ID: 3110041
[TBL] [Abstract][Full Text] [Related]
12. Two sensitive immunometric assays for serum thyroid stimulating hormone evaluated.
Papadea C; Papadea NA; Cate JC; Didyk RB
Ann Clin Lab Sci; 1998; 28(2):88-98. PubMed ID: 9558447
[TBL] [Abstract][Full Text] [Related]
13. Third generation time-resolved immunofluorometric TSH assay for automatic immunoassay system evaluated.
Taimela E; Aalto M; Viikari J; Nuutila P; Irjala K
Scand J Clin Lab Invest; 1995 Oct; 55(6):537-41. PubMed ID: 8571084
[TBL] [Abstract][Full Text] [Related]
14. [Cases of Graves' disease with falsely high TSH values due to interfering substances which cross-link with mouse monoclonal antibodies in the TSH assay kits].
Toshima K; Momotani N; Shimizu K; Saito H; Hisaoka T; Yoshimura H; Ishikawa N; Ito K; Shoji T
Nihon Naibunpi Gakkai Zasshi; 1993 Nov; 69(10):1083-91. PubMed ID: 8282135
[TBL] [Abstract][Full Text] [Related]
15. Time-resolved immunofluorometric assay for thyrotropin improved for enhanced functional sensitivity and clinical discrimination.
Taimela E; Koskinen P; Irjala K
Scand J Clin Lab Invest; 1994 Jul; 54(4):317-21. PubMed ID: 7939375
[TBL] [Abstract][Full Text] [Related]
16. Thyrotroph function assessed by sensitive measurement of thyrotropin with three immunoradiometric assay kits: analytical evaluation and comparison with the thyroliberin stimulation test.
Wians FH; Jacobson JM; Dev J; Heald JI; Ortiz G
Clin Chem; 1988 Mar; 34(3):568-75. PubMed ID: 3127084
[TBL] [Abstract][Full Text] [Related]
17. Thyroid stimulating hormone measurement using a third generation immunometric assay.
Squire CR; Fraser WD
Ann Clin Biochem; 1995 May; 32 ( Pt 3)():307-13. PubMed ID: 7632036
[TBL] [Abstract][Full Text] [Related]
18. Analytical evaluation of an improved procedure for measuring thyrotropin.
González-de-la-Presa B; Palacios G; Bonnin R; Martinez JM; Navarro MA
Clin Chem Lab Med; 1998 Feb; 36(2):103-6. PubMed ID: 9594047
[TBL] [Abstract][Full Text] [Related]
19. Utility of third generation thyrotropin assays in thyroid function testing.
Saller B; Broda N; Heydarian R; Görges R; Mann K
Exp Clin Endocrinol Diabetes; 1998; 106 Suppl 4():S29-33. PubMed ID: 9867193
[TBL] [Abstract][Full Text] [Related]
20. Immunoradiometric assay of serum thyroid stimulating hormone (TSH) as a first-line test in a mixed hospital population.
Rønnov-Jessen D; Skov L; Faber J
Clin Chim Acta; 1987 Sep; 168(1):13-7. PubMed ID: 3665101
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]