  • 1. Polyurethane heart valves: fatigue failure, calcification, and polyurethane structure.
    Bernacca GM; Mackay TG; Wilkinson R; Wheatley DJ
    J Biomed Mater Res; 1997 Mar; 34(3):371-9. PubMed ID: 9086407
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro function and durability of a polyurethane heart valve: material considerations.
    Bernacca GM; Mackay TG; Wheatley DJ
    J Heart Valve Dis; 1996 Sep; 5(5):538-42. PubMed ID: 8894995
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surface modification of polyurethane heart valves: effects on fatigue life and calcification.
    Bernacca GM; Wheatley DJ
    Int J Artif Organs; 1998 Dec; 21(12):814-9. PubMed ID: 9988359
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Polyurethane heart valve durability: effects of leaflet thickness and material.
    Bernacca GM; Mackay TG; Gulbransen MJ; Donn AW; Wheatley DJ
    Int J Artif Organs; 1997 Jun; 20(6):327-31. PubMed ID: 9259209
    [TBL] [Abstract][Full Text] [Related]  

  • 5. New polyurethane heart valve prosthesis: design, manufacture and evaluation.
    Mackay TG; Wheatley DJ; Bernacca GM; Fisher AC; Hindle CS
    Biomaterials; 1996 Oct; 17(19):1857-63. PubMed ID: 8889065
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calcification and fatigue failure in a polyurethane heart value.
    Bernacca GM; Mackay TG; Wilkinson R; Wheatley DJ
    Biomaterials; 1995 Mar; 16(4):279-85. PubMed ID: 7772667
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vitro function and durability assessment of a novel polyurethane heart valve prosthesis.
    Mackay TG; Bernacca GM; Fisher AC; Hindle CS; Wheatley DJ
    Artif Organs; 1996 Sep; 20(9):1017-25. PubMed ID: 8864023
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In-vitro calcification study of polyurethane heart valves.
    Boloori Zadeh P; Corbett SC; Nayeb-Hashemi H
    Mater Sci Eng C Mater Biol Appl; 2014 Feb; 35():335-40. PubMed ID: 24411385
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of the curvatures and bending strains in open trileaflet heart valves.
    Corden J; David T; Fisher J
    Proc Inst Mech Eng H; 1995; 209(2):121-8. PubMed ID: 7495427
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prevention of polyurethane valve cusp calcification with covalently attached bisphosphonate diethylamino moieties.
    Alferiev I; Stachelek SJ; Lu Z; Fu AL; Sellaro TL; Connolly JM; Bianco RW; Sacks MS; Levy RJ
    J Biomed Mater Res A; 2003 Aug; 66(2):385-95. PubMed ID: 12889009
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new generation of high flex life polyurethane urea for polymer heart valve--studies on in vivo biocompatibility and biodurability.
    Thomas V; Jayabalan M
    J Biomed Mater Res A; 2009 Apr; 89(1):192-205. PubMed ID: 18431755
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calcification of polyurethanes implanted subdermally in rats is enhanced by calciphylaxis.
    Joshi RR; Underwood T; Frautschi JR; Phillips RE; Schoen FJ; Levy RJ
    J Biomed Mater Res; 1996 Jun; 31(2):201-7. PubMed ID: 8731208
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro calcification of bioprosthetic heart valves: report of a novel method and review of the biochemical factors involved.
    Bernacca GM; Mackay TG; Wheatley DJ
    J Heart Valve Dis; 1992 Sep; 1(1):115-30. PubMed ID: 1341215
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Phosphonated polyurethanes that resist calcification.
    Joshi RR; Frautschi JR; Phillips RE; Levy RJ
    J Appl Biomater; 1994; 5(1):65-77. PubMed ID: 10146698
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of Clinically Relevant Elliptical Deformations on the Damage Patterns of Sagging and Stretched Leaflets in a Bioprosthetic Heart Valve.
    Sritharan D; Fathi P; Weaver JD; Retta SM; Wu C; Duraiswamy N
    Cardiovasc Eng Technol; 2018 Sep; 9(3):351-364. PubMed ID: 29948838
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro determination of the curvatures and bending strains acting on the leaflets of polyurethane trileaflet heart valves during leaflet motion.
    Corden J; David T; Fisher J
    Proc Inst Mech Eng H; 1995; 209(4):243-53. PubMed ID: 8907218
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polyurethane: material for the next generation of heart valve prostheses?
    Wheatley DJ; Raco L; Bernacca GM; Sim I; Belcher PR; Boyd JS
    Eur J Cardiothorac Surg; 2000 Apr; 17(4):440-8. PubMed ID: 10773568
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical and morphological study of biostable polyurethane heart valve leaflets explanted from sheep.
    Bernacca GM; Straub I; Wheatley DJ
    J Biomed Mater Res; 2002 Jul; 61(1):138-45. PubMed ID: 12001256
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Collagen fibre-mediated mechanical damage increases calcification of bovine pericardium for use in bioprosthetic heart valves.
    Whelan A; Williams E; Fitzpatrick E; Murphy BP; Gunning PS; O'Reilly D; Lally C
    Acta Biomater; 2021 Jul; 128():384-392. PubMed ID: 33945880
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Failure and hydrodynamic function testing of explanted pericardial and porcine bioprosthetic valves.
    Fisher J; Spyt TJ; Wheatley DJ
    Proc Inst Mech Eng H; 1989; 203(2):65-70. PubMed ID: 2619837
    [TBL] [Abstract][Full Text] [Related]  