These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Design of field-cycled magnetic resonance systems for small animal imaging. Gilbert KM; Handler WB; Scholl TJ; Odegaard JW; Chronik BA Phys Med Biol; 2006 Jun; 51(11):2825-41. PubMed ID: 16723769 [TBL] [Abstract][Full Text] [Related]
23. Tuning and matching networks for MR imaging and spectroscopy. Viohl I; Gullberg GT J Magn Reson Imaging; 1994; 4(4):627-30. PubMed ID: 7949693 [TBL] [Abstract][Full Text] [Related]
24. Dual optimization method of radiofrequency and quasistatic field simulations for reduction of eddy currents generated on 7T radiofrequency coil shielding. Zhao Y; Zhao T; Raval SB; Krishnamurthy N; Zheng H; Harris CT; Handler WB; Chronik BA; Ibrahim TS Magn Reson Med; 2015 Nov; 74(5):1461-9. PubMed ID: 25367703 [TBL] [Abstract][Full Text] [Related]
25. Longitudinal gradient coil optimization in the presence of transient eddy currents. Trakic A; Liu F; Lopez HS; Wang H; Crozier S Magn Reson Med; 2007 Jun; 57(6):1119-30. PubMed ID: 17534904 [TBL] [Abstract][Full Text] [Related]
26. Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation. Markl M; Leupold J; Bieri O; Scheffler K; Hennig J Magn Reson Med; 2005 Oct; 54(4):965-74. PubMed ID: 16155870 [TBL] [Abstract][Full Text] [Related]
27. Development and optimization of hardware for delta relaxation enhanced MRI. Harris CT; Handler WB; Araya Y; Martínez-Santiesteban F; Alford JK; Dalrymple B; Van Sas F; Chronik BA; Scholl TJ Magn Reson Med; 2014 Oct; 72(4):1182-90. PubMed ID: 24407990 [TBL] [Abstract][Full Text] [Related]
28. Eddy current effects on a clinical 7T-68 cm bore scanner. Kickler N; van der Zwaag W; Mekle R; Kober T; Marques JP; Krueger G; Gruetter R MAGMA; 2010 Feb; 23(1):39-43. PubMed ID: 20012152 [TBL] [Abstract][Full Text] [Related]
29. High field body MR imaging: preliminary experiences. Uematsu H; Takahashi M; Dougherty L; Hatabu H Clin Imaging; 2004; 28(3):159-62. PubMed ID: 15158217 [TBL] [Abstract][Full Text] [Related]
33. Design of non-selective refocusing pulses with phase-free rotation axis by gradient ascent pulse engineering algorithm in parallel transmission at 7T. Massire A; Cloos MA; Vignaud A; Le Bihan D; Amadon A; Boulant N J Magn Reson; 2013 May; 230():76-83. PubMed ID: 23454576 [TBL] [Abstract][Full Text] [Related]
34. Rapid polarizing field cycling in magnetic resonance imaging. Matter NI; Scott GC; Grafendorfer T; Macovski A; Conolly SM IEEE Trans Med Imaging; 2006 Jan; 25(1):84-93. PubMed ID: 16398417 [TBL] [Abstract][Full Text] [Related]
35. Fast imaging using subencoding data sets from multiple detectors. Ra JB; Rim CY Magn Reson Med; 1993 Jul; 30(1):142-5. PubMed ID: 8371669 [TBL] [Abstract][Full Text] [Related]
36. Influence of noise correlation in multiple-coil statistical models with sum of squares reconstruction. Aja-Fernández S; Tristán-Vega A Magn Reson Med; 2012 Feb; 67(2):580-5. PubMed ID: 21656560 [TBL] [Abstract][Full Text] [Related]
37. Toward shielding improvements in MRI gradients and other systems. Brown RW; Cheng YC; Eagan TP; Kidane TK; Mathur H; Petschek RG; Sherwin WG; Shvartsman SM; Willig JD MAGMA; 2002 Jan; 13(3):186-92. PubMed ID: 11755095 [TBL] [Abstract][Full Text] [Related]
38. Unwrapping eddy current compensation: improved compensation of eddy current induced baseline shifts in high-resolution phase-contrast MRI at 9.4 Tesla. Espe EK; Zhang L; Sjaastad I Magn Reson Med; 2014 Oct; 72(4):1096-102. PubMed ID: 24264935 [TBL] [Abstract][Full Text] [Related]
39. Single point measurements of magnetic field gradient waveform. Goodyear DJ; Shea M; Beyea SD; Shah NJ; Balcom BJ J Magn Reson; 2003 Jul; 163(1):1-7. PubMed ID: 12852901 [TBL] [Abstract][Full Text] [Related]