These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 9098593)

  • 41. Tc-99m sestamibi cardiac SPECT imaging during coronary artery occlusion in humans: comparison with dipyridamole stress studies.
    Borges-Neto S; Watson JE; Miller MJ
    Radiology; 1996 Mar; 198(3):751-4. PubMed ID: 8628865
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The variable extent of jeopardized myocardium in patients with single vessel coronary artery disease: quantification by thallium-201 single photon emission computed tomography.
    Mahmarian JJ; Pratt CM; Boyce TM; Verani MS
    J Am Coll Cardiol; 1991 Feb; 17(2):355-62. PubMed ID: 1991891
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography.
    Berman DS; Hachamovitch R; Kiat H; Cohen I; Cabico JA; Wang FP; Friedman JD; Germano G; Van Train K; Diamond GA
    J Am Coll Cardiol; 1995 Sep; 26(3):639-47. PubMed ID: 7642853
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Simultaneous dobutamine stress echocardiography and technetium-99m isonitrile single-photon emission computed tomography in patients with suspected coronary artery disease.
    Forster T; McNeill AJ; Salustri A; Reijs AE; el-Said ES; Roelandt JR; Fioretti PM
    J Am Coll Cardiol; 1993 Jun; 21(7):1591-6. PubMed ID: 8496524
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability.
    De Boer J; Slart RH; Blanksma PK; Willemsen AT; Jager PL; Paans AM; Vaalburg W; Piers DA
    Nucl Med Commun; 2003 Mar; 24(3):251-7. PubMed ID: 12612465
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Dipyridamole myocardial perfusion single photon emission computed tomography in patients with slow coronary flow.
    Demirkol MO; Yaymaci B; Mutlu B
    Coron Artery Dis; 2002 Jun; 13(4):223-9. PubMed ID: 12193849
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Diagnostic efficacy of stress technetium 99m-labeled sestamibi myocardial perfusion single-photon emission computed tomography in detection of coronary artery disease among patients over age 80.
    Wang FP; Amanullah AM; Kiat H; Friedman JD; Berman DS
    J Nucl Cardiol; 1995; 2(5):380-8. PubMed ID: 9420817
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Comparison of (99)mTc-methoxyisobutylisonitrile myocardial single-photon emission computed tomography and electron beam computed tomography for detecting coronary artery disease in patients with no myocardial infarction.
    Yao ZM; Li W; Qu WY; Zhou C; He Q; Ji FS
    Chin Med J (Engl); 2004 May; 117(5):700-5. PubMed ID: 15161537
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Relationship of gated SPECT ventricular function parameters to angiographic measurements.
    Nichols K; Tamis J; DePuey EG; Mieres J; Malhotra S; Rozanski A
    J Nucl Cardiol; 1998; 5(3):295-303. PubMed ID: 9669584
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Identification of severe or extensive coronary artery disease in women by adenosine technetium-99m sestamibi SPECT.
    Amanullah AM; Berman DS; Hachamovitch R; Kiat H; Kang X; Friedman JD
    Am J Cardiol; 1997 Jul; 80(2):132-7. PubMed ID: 9230147
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Evaluation of hemodynamic significance of arteriovenous coronary fistulas: diagnostic integration of coronary angiography and stress/rest myocardial scintigraphy].
    Rubini G; Ettorre GC; Sebastiani M; Bovenzi F
    Radiol Med; 2000 Dec; 100(6):453-8. PubMed ID: 11307506
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Assessment of the area at risk after acute myocardial infarction using 123I-MIBG SPECT: Comparison with the angiographic APPROACH-score.
    Vauchot F; Ben Bouallègue F; Hedon C; Piot C; Roubille F; Mariano-Goulart D
    J Nucl Cardiol; 2018 Apr; 25(2):572-580. PubMed ID: 27549427
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Assessment of myocardial viability in chronic coronary artery disease using technetium-99m sestamibi SPECT. Correlation with histologic and positron emission tomographic studies and functional follow-up.
    Maes AF; Borgers M; Flameng W; Nuyts JL; van de Werf F; Ausma JJ; Sergeant P; Mortelmans LA
    J Am Coll Cardiol; 1997 Jan; 29(1):62-8. PubMed ID: 8996296
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Prediction of functional recovery in patients with chronic coronary artery disease and left ventricular dysfunction combining the evaluation of myocardial perfusion and of contractile reserve using nitrate-enhanced technetium-99m sestamibi gated single-photon emission computed tomography and dobutamine stress.
    Leoncini M; Marcucci G; Sciagrà R; Frascarelli F; Simonetti I; Bini L; Maioli M; Mennuti A; Dabizzi RP
    Am J Cardiol; 2001 Jun; 87(12):1346-50. PubMed ID: 11397351
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Relationship between the location of the most severe myocardial perfusion defects, the most severe coronary artery stenosis, and the site of subsequent myocardial infarction.
    Candell-Riera J; Pereztol-Valdés O; Santana-Boado C; Missorici M; Oller-Martínez G; Aguadé-Bruix S; Castell-Conesa J; Simó M; Díez-Castro MJ; Soler-Soler J
    J Nucl Med; 2001 Apr; 42(4):558-63. PubMed ID: 11337541
    [TBL] [Abstract][Full Text] [Related]  

  • 56. SPECT versus planar 99mTc-sestamibi myocardial scintigraphy: comparison of accuracy and impact on patient management in chronic ischemic heart disease.
    Cramer MJ; van der Wall EE; Verzijlbergen JF; Jaarsma W; Niemeyer MG; Zwindrman AH; Ascoop CA; Pauwels EK
    Q J Nucl Med; 1997 Mar; 41(1):1-9. PubMed ID: 9195847
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study.
    Senior R; Moreo A; Gaibazzi N; Agati L; Tiemann K; Shivalkar B; von Bardeleben S; Galiuto L; Lardoux H; Trocino G; Carrió I; Le Guludec D; Sambuceti G; Becher H; Colonna P; Ten Cate F; Bramucci E; Cohen A; Bezante G; Aggeli C; Kasprzak JD
    J Am Coll Cardiol; 2013 Oct; 62(15):1353-61. PubMed ID: 23770168
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Independent and incremental value of coronary artery calcium for predicting the extent of angiographic coronary artery disease: comparison with cardiac risk factors and radionuclide perfusion imaging.
    Schmermund A; Denktas AE; Rumberger JA; Christian TF; Sheedy PF; Bailey KR; Schwartz RS
    J Am Coll Cardiol; 1999 Sep; 34(3):777-86. PubMed ID: 10483960
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Myocardial contrast echocardiography in human beings: correlation of resting perfusion defects to sestamibi single photon emission computed tomography.
    Meza MF; Mobarek S; Sonnemaker R; Shuler S; Ramee SR; Collins TJ; White CJ; Aristizabal D; Murgo JP; Cheirif J
    Am Heart J; 1996 Sep; 132(3):528-35. PubMed ID: 8800021
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Noninvasive detection of collateral flow to the infarct-related coronary artery in patients after myocardial infarction by Tl-201 tomographic imaging.
    Chouraqui P; Asman A; Guetta V; Daka F; Baron J; Rozen E; Sternberg M; Shechter M
    J Nucl Cardiol; 2003; 10(6):669-75. PubMed ID: 14668780
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.