These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
277 related articles for article (PubMed ID: 9099059)
1. Evaluation of manometric temperature measurement as a method of monitoring product temperature during lyophilization. Milton N; Pikal MJ; Roy ML; Nail SL PDA J Pharm Sci Technol; 1997; 51(1):7-16. PubMed ID: 9099059 [TBL] [Abstract][Full Text] [Related]
2. Determination of mass and heat transfer parameters during freeze-drying cycles of pharmaceutical products. Hottot A; Vessot S; Andrieu J PDA J Pharm Sci Technol; 2005; 59(2):138-53. PubMed ID: 15971546 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: part I, product temperature measurement. Tang X; Nail SL; Pikal MJ AAPS PharmSciTech; 2006 Feb; 7(1):E14. PubMed ID: 16584144 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: part II measurement of dry-layer resistance. Tang XC; Nail SL; Pikal MJ AAPS PharmSciTech; 2006; 7(4):93. PubMed ID: 17285744 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of manometric temperature measurement (MTM), a process analytical technology tool in freeze drying, part III: heat and mass transfer measurement. Tang XC; Nail SL; Pikal MJ AAPS PharmSciTech; 2006; 7(4):97. PubMed ID: 17285746 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: Part I, product temperature measurement. Tang X; Nail SL; Pikal MJ AAPS PharmSciTech; 2006 Mar; 7(1):E95-E103. PubMed ID: 28290029 [TBL] [Abstract][Full Text] [Related]
7. Effect of the design of the stopper including dimension, type, and vent area on lyophilization process. Mungikar A; Ludzinski M; Kamat M PDA J Pharm Sci Technol; 2010; 64(6):507-16. PubMed ID: 21502061 [TBL] [Abstract][Full Text] [Related]
8. Freeze-drying process design by manometric temperature measurement: design of a smart freeze-dryer. Tang XC; Nail SL; Pikal MJ Pharm Res; 2005 Apr; 22(4):685-700. PubMed ID: 15889467 [TBL] [Abstract][Full Text] [Related]
9. Rapid determination of dry layer mass transfer resistance for various pharmaceutical formulations during primary drying using product temperature profiles. Kuu WY; Hardwick LM; Akers MJ Int J Pharm; 2006 Apr; 313(1-2):99-113. PubMed ID: 16513303 [TBL] [Abstract][Full Text] [Related]
10. Protein purification process engineering. Freeze drying: A practical overview. Gatlin LA; Nail SL Bioprocess Technol; 1994; 18():317-67. PubMed ID: 7764173 [TBL] [Abstract][Full Text] [Related]
11. Fundamentals of freeze-drying. Nail SL; Jiang S; Chongprasert S; Knopp SA Pharm Biotechnol; 2002; 14():281-360. PubMed ID: 12189727 [TBL] [Abstract][Full Text] [Related]
12. Heat and mass transfer scale-up issues during freeze drying: II. Control and characterization of the degree of supercooling. Rambhatla S; Ramot R; Bhugra C; Pikal MJ AAPS PharmSciTech; 2004 Aug; 5(4):e58. PubMed ID: 15760055 [TBL] [Abstract][Full Text] [Related]
13. Freeze-drying in novel container system: Characterization of heat and mass transfer in glass syringes. Patel SM; Pikal MJ J Pharm Sci; 2010 Jul; 99(7):3188-204. PubMed ID: 20166199 [TBL] [Abstract][Full Text] [Related]
14. Mass and heat transfer in vial freeze-drying of pharmaceuticals: role of the vial. Pikal MJ; Roy ML; Shah S J Pharm Sci; 1984 Sep; 73(9):1224-37. PubMed ID: 6491939 [TBL] [Abstract][Full Text] [Related]
15. Use of manometric temperature measurements (MTM) to characterize the freeze-drying behavior of amorphous protein formulations. Johnson RE; Oldroyd ME; Ahmed SS; Gieseler H; Lewis LM J Pharm Sci; 2010 Jun; 99(6):2863-73. PubMed ID: 19960528 [TBL] [Abstract][Full Text] [Related]
16. Use of a soft sensor for the fast estimation of dried cake resistance during a freeze-drying cycle. Bosca S; Barresi AA; Fissore D Int J Pharm; 2013 Jul; 451(1-2):23-33. PubMed ID: 23624086 [TBL] [Abstract][Full Text] [Related]
17. Use of soft sensors to monitor a pharmaceuticals freeze-drying process in vials. Bosca S; Barresi AA; Fissore D Pharm Dev Technol; 2014 Mar; 19(2):148-59. PubMed ID: 23336717 [TBL] [Abstract][Full Text] [Related]
18. The application of dual-electrode through vial impedance spectroscopy for the determination of ice interface temperatures, primary drying rate and vial heat transfer coefficient in lyophilization process development. Smith G; Jeeraruangrattana Y; Ermolina I Eur J Pharm Biopharm; 2018 Sep; 130():224-235. PubMed ID: 29940225 [TBL] [Abstract][Full Text] [Related]