These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 9099316)

  • 1. Determination of gas-trapping during high frequency oscillatory ventilation.
    Alexander J; Milner AD
    Acta Paediatr; 1997 Mar; 86(3):268-73. PubMed ID: 9099316
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Gas trapping with high-frequency ventilation: jet versus oscillatory ventilation.
    Bancalari A; Gerhardt T; Bancalari E; Suguihara C; Hehre D; Reifenberg L; Goldberg RN
    J Pediatr; 1987 Apr; 110(4):617-22. PubMed ID: 3470493
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Using very high frequencies with very low lung volumes during high-frequency oscillatory ventilation to protect the immature lung. A pilot study.
    González-Pacheco N; Sánchez-Luna M; Ramos-Navarro C; Navarro-Patiño N; de la Blanca AR
    J Perinatol; 2016 Apr; 36(4):306-10. PubMed ID: 26741575
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Unexpected effect of recruitment procedure on lung volume measured by respiratory inductive plethysmography (RIP) during high frequency oscillatory ventilation (HFOV) in preterm neonates with respiratory distress syndrome (RDS).
    Vento G; Tana M; Tirone C; Aurilia C; Lio A; Perelli S; Ricci C; Romagnoli C
    J Matern Fetal Neonatal Med; 2011 Oct; 24 Suppl 1():159-62. PubMed ID: 21888522
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Target volume-guarantee in high-frequency oscillatory ventilation for preterm respiratory distress syndrome: Low volumes and high frequencies lead to adequate ventilation.
    Solís-García G; González-Pacheco N; Ramos-Navarro C; Rodríguez Sánchez de la Blanca A; Sánchez-Luna M
    Pediatr Pulmonol; 2021 Aug; 56(8):2597-2603. PubMed ID: 34107176
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of the I/E ratio on CO2 removal during high-frequency oscillatory ventilation with volume guarantee in a neonatal animal model of RDS.
    Sánchez-Luna M; González-Pacheco N; Santos M; Blanco Á; Orden C; Belik J; Tendillo FJ
    Eur J Pediatr; 2016 Oct; 175(10):1343-51. PubMed ID: 27595847
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of Volume Guarantee on High-Frequency Oscillatory Ventilation in Preterm Infants: A Randomized Crossover Clinical Trial.
    Iscan B; Duman N; Tuzun F; Kumral A; Ozkan H
    Neonatology; 2015; 108(4):277-82. PubMed ID: 26330156
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sustained inflations improve respiratory compliance during high-frequency oscillatory ventilation but not during large tidal volume positive-pressure ventilation in rabbits.
    Bond DM; McAloon J; Froese AB
    Crit Care Med; 1994 Aug; 22(8):1269-77. PubMed ID: 8045147
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Elective high-frequency oscillatory ventilation versus conventional ventilation for acute pulmonary dysfunction in preterm infants.
    Neonatology; 2013; 103(1):7-8; discussion 8-9. PubMed ID: 23037971
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome.
    Hager DN; Fessler HE; Kaczka DW; Shanholtz CB; Fuld MK; Simon BA; Brower RG
    Crit Care Med; 2007 Jun; 35(6):1522-9. PubMed ID: 17440422
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Higher frequency ventilation attenuates lung injury during high-frequency oscillatory ventilation in sheep models of acute respiratory distress syndrome.
    Liu S; Yi Y; Wang M; Chen Q; Huang Y; Liu L; Xie J; Zhou D; Qiu H
    Anesthesiology; 2013 Aug; 119(2):398-411. PubMed ID: 23598290
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimization of high-frequency oscillatory ventilation for the treatment of experimental pneumothorax.
    Ellsbury DL; Klein JM; Segar JL
    Crit Care Med; 2002 May; 30(5):1131-5. PubMed ID: 12006814
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-frequency oscillatory ventilation with volume guarantee: a single-centre experience.
    Belteki G; Morley CJ
    Arch Dis Child Fetal Neonatal Ed; 2019 Jul; 104(4):F384-F389. PubMed ID: 30217870
    [TBL] [Abstract][Full Text] [Related]  

  • 14. DCO
    González-Pacheco N; Sánchez-Luna M; Arribas-Sánchez C; Santos-González M; Orden-Quinto C; Tendillo-Cortijo F
    Eur J Pediatr; 2020 Mar; 179(3):499-506. PubMed ID: 31823075
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New Ventilator Strategies: High-Frequency Oscillatory Ventilation Combined with Volume Guarantee.
    Sánchez-Luna M; González-Pacheco N; Belik J; Santos M; Tendillo F
    Am J Perinatol; 2018 May; 35(6):545-548. PubMed ID: 29694993
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of tidal lung volumes in neonates during high-frequency oscillation.
    Hoskyns EW; Milner AD; Hopkin IE
    J Biomed Eng; 1992 Jan; 14(1):16-20. PubMed ID: 1569734
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of Lung Volume and Hemodynamic Changes During High-Frequency Ventilation Recruitment in Preterm Neonates With Respiratory Distress Syndrome.
    Tana M; Polglase GR; Cota F; Tirone C; Aurilia C; Lio A; Ricci C; Romagnoli C; Vento G
    Crit Care Med; 2015 Aug; 43(8):1685-91. PubMed ID: 25803651
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of Volume Guaranteed Ventilation Combined with Two Different Modes in Preterm Infants.
    Unal S; Ergenekon E; Aktas S; Altuntas N; Beken S; Kazanci E; Kulali F; Gulbahar O; Hirfanoglu IM; Onal E; Turkyilmaz C; Koc E; Atalay Y
    Respir Care; 2017 Dec; 62(12):1525-1532. PubMed ID: 28698268
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Randomized study of high-frequency oscillatory ventilation in infants with severe respiratory distress syndrome. HiFO Study Group.
    J Pediatr; 1993 Apr; 122(4):609-19. PubMed ID: 8463913
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-frequency oscillatory ventilation in adults with acute respiratory distress syndrome.
    Hager DN
    Curr Opin Anaesthesiol; 2012 Feb; 25(1):17-23. PubMed ID: 22157194
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.