These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

326 related articles for article (PubMed ID: 9101645)

  • 1. A 120-MHz ultrasound probe for tissue imaging.
    Yokosawa K; Shinomura R; Sano S; Ito Y; Ishikawa S; Sato Y
    Ultrason Imaging; 1996 Oct; 18(4):231-9. PubMed ID: 9101645
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Acoustic microscopy system: design and preliminary results.
    Liu JB; Peterson JN; Forsberg F; Jaeger MD; Kynor DB; Kline-Schoder RJ
    Ultrasonics; 2004 Apr; 42(1-9):337-41. PubMed ID: 15047308
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Phantom evaluation of stacked-type dual-frequency 1-3 composite transducers: A feasibility study on intracavitary acoustic angiography.
    Kim J; Li S; Kasoji S; Dayton PA; Jiang X
    Ultrasonics; 2015 Dec; 63():7-15. PubMed ID: 26112426
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 45 to 55 MHz needle-based ultrasound system for invasive imaging.
    Lockwood GR; Ryan LK; Foster FS
    Ultrason Imaging; 1993 Jan; 15(1):1-13. PubMed ID: 8328115
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterization of a broadband all-optical ultrasound transducer-from optical and acoustical properties to imaging.
    Hou Y; Kim JS; Huang SW; Ashkenazi S; Guo LJ; O'Donnell M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Aug; 55(8):1867-77. PubMed ID: 18986929
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High frequency piezoelectric MEMS ultrasound transducers.
    Mina IG; Kim H; Kim I; Park SK; Choi K; Jackson TN; Tutwiler RL; Trolier-McKinstry S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Dec; 54(12):2422-30. PubMed ID: 18276533
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultrasonic imaging using air-coupled P(VDF/TrFE) transducers at 2 MHz.
    Takahashi S; Ohigashi H
    Ultrasonics; 2009 May; 49(4-5):495-8. PubMed ID: 19215951
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.
    Cannata JM; Ritter TA; Chen WH; Silverman RH; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Nov; 50(11):1548-57. PubMed ID: 14682638
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound grayscale image quality comparison between a 2D intracavitary transducer and a 3D intracavitary transducer used in 2D mode: A phantom study.
    Zhou W; Long Z; Tradup DJ; Stekel SF; Browne JE; Brown DL; Hangiandreou NJ
    J Appl Clin Med Phys; 2019 Jun; 20(6):134-140. PubMed ID: 31002482
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 35 MHz/105 MHz Dual-Element Focused Transducer for Intravascular Ultrasound Tissue Imaging Using the Third Harmonic.
    Lee J; Moon JY; Chang JH
    Sensors (Basel); 2018 Jul; 18(7):. PubMed ID: 30011948
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dual-mode transducers for ultrasound imaging and thermal therapy.
    Owen NR; Chapelon JY; Bouchoux G; Berriet R; Fleury G; Lafon C
    Ultrasonics; 2010 Feb; 50(2):216-20. PubMed ID: 19758673
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Polyurea thin film ultrasonic transducers for nondestructive testing and medical imaging.
    Nakazawa M; Kosugi T; Nagatsuka H; Maezawa A; Nakamura K; Ueha S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Oct; 54(10):2165-74. PubMed ID: 18019256
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design and acoustic characterization of limited diffraction ultrasonic devices.
    Aulet A; Núñez I; Moreno E; Eiras JA; Negreira CA
    J Acoust Soc Am; 2010 May; 127(5):2737-40. PubMed ID: 21117721
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fabrication and performance of high-frequency composite transducers with triangular-pillar geometry.
    Brown JA; Chérin E; Yin J; Foster FS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Apr; 56(4):827-36. PubMed ID: 19406712
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Arbitrary shaped, liquid filled reverberators with non-resonant transducers for broadband focusing of ultrasound using Time Reversed Acoustics.
    Sarvazyan A; Fillinger L
    Ultrasonics; 2009 Mar; 49(3):301-5. PubMed ID: 19062060
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of High-Frequency (>60 MHz) Intravascular Ultrasound (IVUS) Transducer by Using Asymmetric Electrodes for Improved Beam Profile.
    Sung JH; Jeong JS
    Sensors (Basel); 2018 Dec; 18(12):. PubMed ID: 30551639
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lens-focused transducer modeling using an extended KLM model.
    Maréchal P; Levassort F; Tran-Huu-Hue LP; Lethiecq M
    Ultrasonics; 2007 May; 46(2):155-67. PubMed ID: 17382986
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A 30-MHz piezo-composite ultrasound array for medical imaging applications.
    Ritter TA; Shrout TR; Tutwiler R; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 Feb; 49(2):217-30. PubMed ID: 11885679
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Eco-Friendly Highly Sensitive Transducers Based on a New KNN-NTK-FM Lead-Free Piezoelectric Ceramic for High-Frequency Biomedical Ultrasonic Imaging Applications.
    Chen R; Jiang L; Zhang T; Matsuoka T; Yamazaki M; Qian X; Lu G; Safari A; Zhu J; Shung KK; Ma T; Zhou Q
    IEEE Trans Biomed Eng; 2019 Jun; 66(6):1580-1587. PubMed ID: 30452346
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigation of transmit and receive performance at the fundamental and third harmonic resonance frequency of a medical ultrasound transducer.
    Frijlink ME; Løvstakken L; Torp H
    Ultrasonics; 2009 Dec; 49(8):601-4. PubMed ID: 19403153
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.