21. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients]. Schlote T; Landenberger H Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316 [TBL] [Abstract][Full Text] [Related]
22. Intraocular pressure measurement with the Tono-Pen through soft contact lenses. Panek WC; Boothe WA; Lee DA; Zemplenyi E; Pettit TH Am J Ophthalmol; 1990 Jan; 109(1):62-5. PubMed ID: 2297033 [TBL] [Abstract][Full Text] [Related]
23. Applanation tonometry in contact lens practice. Kreda SH J Am Optom Assoc; 1987 Mar; 58(3):208-10. PubMed ID: 3571822 [TBL] [Abstract][Full Text] [Related]
24. Goldmann tonometry versus the Tono-Pen XL for intraocular pressure measurement: an evaluation of the potential impact on clinical decision making in glaucoma. Carrim ZI; Lavy TE Ophthalmic Physiol Opt; 2009 Nov; 29(6):648-51. PubMed ID: 19821927 [TBL] [Abstract][Full Text] [Related]
25. Intraoperative assessment of intraocular pressure in vitrectomized air-filled and fluid-filled eyes. Moon CH; Choi KS; Rhee MR; Lee SJ Acta Ophthalmol; 2013 Nov; 91(7):e524-8. PubMed ID: 23710577 [TBL] [Abstract][Full Text] [Related]
26. The impact of corneal edema on intraocular pressure measurements using goldmann applanation tonometry, Tono-Pen XL, iCare, and ORA: an in vitro model. Neuburger M; Maier P; Böhringer D; Reinhard T; F Jordan J J Glaucoma; 2013 Sep; 22(7):584-90. PubMed ID: 22366704 [TBL] [Abstract][Full Text] [Related]
27. Evaluation of the intraocular pressure measured with the ocular response analyzer. Ogbuehi KC; Almubrad TM Curr Eye Res; 2010 Jul; 35(7):587-96. PubMed ID: 20597645 [TBL] [Abstract][Full Text] [Related]
28. Effect of corneal stiffening on Goldmann applanation tonometry and Tono-Pen measurements in canine eyes. Tang J; Pan X; Weber PA; Liu J Invest Ophthalmol Vis Sci; 2012 Mar; 53(3):1397-405. PubMed ID: 22297494 [TBL] [Abstract][Full Text] [Related]
29. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology. von Spiessen L; Karck J; Rohn K; Meyer-Lindenberg A Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625 [TBL] [Abstract][Full Text] [Related]
30. The influence of soft contact lenses on the intraocular pressure measurement. Firat PG; Cankaya C; Doganay S; Cavdar M; Duman S; Ozsoy E; Koc B Eye (Lond); 2012 Feb; 26(2):278-82. PubMed ID: 22079968 [TBL] [Abstract][Full Text] [Related]
32. Oculab Tono-Pen, Goldmann applanation tonometry, and pneumatic tonometry for intraocular pressure assessment in gas-filled eyes. Hines MW; Jost BF; Fogelman KL Am J Ophthalmol; 1988 Aug; 106(2):174-9. PubMed ID: 3400759 [TBL] [Abstract][Full Text] [Related]
33. Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings. Berk TA; Yang PT; Chan CC J Glaucoma; 2016 Oct; 25(10):e897-e904. PubMed ID: 26918913 [TBL] [Abstract][Full Text] [Related]
34. The effects of the modulus of the lens material on intraocular pressure measurement through soft contact lenses. Boyraz S; Güngör I Ir J Med Sci; 2013 Sep; 182(3):331-5. PubMed ID: 23207914 [TBL] [Abstract][Full Text] [Related]
35. A Comparative Study of Rebound Tonometry With Tonopen and Goldmann Applanation Tonometry Following Vitreoretinal Surgery. Grewal DS; Stinnett SS; Folgar FA; Schneider EW; Vajzovic L; Asrani S; Freedman SF; Mruthyunjaya P; Hahn P Am J Ophthalmol; 2016 Jan; 161():22-8.e1-8. PubMed ID: 26408266 [TBL] [Abstract][Full Text] [Related]
36. Intraocular pressure difference in Goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients. dos Santos MG; Makk S; Berghold A; Eckhardt M; Haas A Ophthalmology; 1998 Dec; 105(12):2260-3. PubMed ID: 9855157 [TBL] [Abstract][Full Text] [Related]
37. The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements. Hamilton KE; Pye DC; Hali A; Lin C; Kam P; Ngyuen T J Glaucoma; 2007 Jan; 16(1):153-8. PubMed ID: 17224766 [TBL] [Abstract][Full Text] [Related]
38. The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology. Browning AC; Bhan A; Rotchford AP; Shah S; Dua HS Br J Ophthalmol; 2004 Nov; 88(11):1395-9. PubMed ID: 15489480 [TBL] [Abstract][Full Text] [Related]
39. The effect of repeated applanation on subsequent IOP measurements. AlMubrad TM; Ogbuehi KC Clin Exp Optom; 2008 Nov; 91(6):524-9. PubMed ID: 18651843 [TBL] [Abstract][Full Text] [Related]
40. Intraocular pressure measurement through two types of plano therapeutic soft contact lenses in dogs. Miller PE; Murphy CJ Am J Vet Res; 1995 Nov; 56(11):1418-20. PubMed ID: 8585650 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]