These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 9108980)

  • 21. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients].
    Schlote T; Landenberger H
    Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Intraocular pressure measurement with the Tono-Pen through soft contact lenses.
    Panek WC; Boothe WA; Lee DA; Zemplenyi E; Pettit TH
    Am J Ophthalmol; 1990 Jan; 109(1):62-5. PubMed ID: 2297033
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Applanation tonometry in contact lens practice.
    Kreda SH
    J Am Optom Assoc; 1987 Mar; 58(3):208-10. PubMed ID: 3571822
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Goldmann tonometry versus the Tono-Pen XL for intraocular pressure measurement: an evaluation of the potential impact on clinical decision making in glaucoma.
    Carrim ZI; Lavy TE
    Ophthalmic Physiol Opt; 2009 Nov; 29(6):648-51. PubMed ID: 19821927
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Intraoperative assessment of intraocular pressure in vitrectomized air-filled and fluid-filled eyes.
    Moon CH; Choi KS; Rhee MR; Lee SJ
    Acta Ophthalmol; 2013 Nov; 91(7):e524-8. PubMed ID: 23710577
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The impact of corneal edema on intraocular pressure measurements using goldmann applanation tonometry, Tono-Pen XL, iCare, and ORA: an in vitro model.
    Neuburger M; Maier P; Böhringer D; Reinhard T; F Jordan J
    J Glaucoma; 2013 Sep; 22(7):584-90. PubMed ID: 22366704
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of the intraocular pressure measured with the ocular response analyzer.
    Ogbuehi KC; Almubrad TM
    Curr Eye Res; 2010 Jul; 35(7):587-96. PubMed ID: 20597645
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of corneal stiffening on Goldmann applanation tonometry and Tono-Pen measurements in canine eyes.
    Tang J; Pan X; Weber PA; Liu J
    Invest Ophthalmol Vis Sci; 2012 Mar; 53(3):1397-405. PubMed ID: 22297494
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology.
    von Spiessen L; Karck J; Rohn K; Meyer-Lindenberg A
    Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The influence of soft contact lenses on the intraocular pressure measurement.
    Firat PG; Cankaya C; Doganay S; Cavdar M; Duman S; Ozsoy E; Koc B
    Eye (Lond); 2012 Feb; 26(2):278-82. PubMed ID: 22079968
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry.
    Hsu SY; Sheu MM; Hsu AH; Wu KY; Yeh JI; Tien JN; Tsai RK
    Eye (Lond); 2009 Jul; 23(7):1582-8. PubMed ID: 19407845
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Oculab Tono-Pen, Goldmann applanation tonometry, and pneumatic tonometry for intraocular pressure assessment in gas-filled eyes.
    Hines MW; Jost BF; Fogelman KL
    Am J Ophthalmol; 1988 Aug; 106(2):174-9. PubMed ID: 3400759
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings.
    Berk TA; Yang PT; Chan CC
    J Glaucoma; 2016 Oct; 25(10):e897-e904. PubMed ID: 26918913
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The effects of the modulus of the lens material on intraocular pressure measurement through soft contact lenses.
    Boyraz S; Güngör I
    Ir J Med Sci; 2013 Sep; 182(3):331-5. PubMed ID: 23207914
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Comparative Study of Rebound Tonometry With Tonopen and Goldmann Applanation Tonometry Following Vitreoretinal Surgery.
    Grewal DS; Stinnett SS; Folgar FA; Schneider EW; Vajzovic L; Asrani S; Freedman SF; Mruthyunjaya P; Hahn P
    Am J Ophthalmol; 2016 Jan; 161():22-8.e1-8. PubMed ID: 26408266
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Intraocular pressure difference in Goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients.
    dos Santos MG; Makk S; Berghold A; Eckhardt M; Haas A
    Ophthalmology; 1998 Dec; 105(12):2260-3. PubMed ID: 9855157
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements.
    Hamilton KE; Pye DC; Hali A; Lin C; Kam P; Ngyuen T
    J Glaucoma; 2007 Jan; 16(1):153-8. PubMed ID: 17224766
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.
    Browning AC; Bhan A; Rotchford AP; Shah S; Dua HS
    Br J Ophthalmol; 2004 Nov; 88(11):1395-9. PubMed ID: 15489480
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The effect of repeated applanation on subsequent IOP measurements.
    AlMubrad TM; Ogbuehi KC
    Clin Exp Optom; 2008 Nov; 91(6):524-9. PubMed ID: 18651843
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Intraocular pressure measurement through two types of plano therapeutic soft contact lenses in dogs.
    Miller PE; Murphy CJ
    Am J Vet Res; 1995 Nov; 56(11):1418-20. PubMed ID: 8585650
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.