These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 9110193)

  • 41. Novel method for assessing myocardial perfusion: visualization and measurement of intramyocardial coronary blood flow in the entire left ventricular wall using contrast enhanced, high frequency Doppler echocardiography.
    Ujino K; Teragaki M; Ota T; Muro T; Watanabe H; Yoshiyama M; Takeuchi K; Yoshikawa J
    Jpn Heart J; 2001 Jan; 42(1):101-13. PubMed ID: 11324799
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [Stress echocardiography: evaluation of left ventricular function after administration of the transpulmonary echo contrast medium SHU 508 A].
    Beckmann S; Schartl M; Bocksch W; Paeprer H
    Z Kardiol; 1993 May; 82(5):317-23. PubMed ID: 8328182
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Quantitative assessment of harmonic power doppler myocardial perfusion imaging with intravenous Levovist in patients with myocardial infarction: comparison with myocardial viability evaluated by coronary flow reserve and coronary flow pattern of infarct-related artery.
    Tani T; Tanabe K; Tani M; Ono F; Katayama M; Tamita K; Kaji S; Yamamuro A; Nagai K; Shiratori K; Morioka S; Kihara Y
    Cardiovasc Ultrasound; 2005 Aug; 3():22. PubMed ID: 16107221
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Demonstration of penetrating intramyocardial coronary arteries with high-frequency transthoracic echocardiography and Doppler in human subjects.
    Youn HJ; Redberg RF; Schiller NB; Foster E
    J Am Soc Echocardiogr; 1999 Jan; 12(1):55-63. PubMed ID: 9882779
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Feasibility of perflutren microsphere contrast transthoracic echocardiography in the visualization of ventricular endocardium during venovenous extracorporeal membrane oxygenation in a validated ovine model.
    Platts DG; Diab S; Dunster KR; Shekar K; Burstow DJ; Sim B; Tunbridge M; McDonald C; Chemonges S; Chan J; Fraser JF
    Echocardiography; 2015 Mar; 32(3):548-56. PubMed ID: 25059883
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Echocardiographic and cardiac Doppler assessment of mice.
    Pollick C; Hale SL; Kloner RA
    J Am Soc Echocardiogr; 1995; 8(5 Pt 1):602-10. PubMed ID: 9417202
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Usefulness of left ventricular opacification with intravenous contrast echocardiography in patients with asymptomatic negative T waves on electrocardiography].
    Zhu H; Muro T; Hozumi T; Watanabe H; Abo K; Nakao M; Yoshikawa J
    J Cardiol; 2002 Dec; 40(6):259-65. PubMed ID: 12528647
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The role of contrast enhancement in echocardiographic assessment of left ventricular function.
    Lang RM; Mor-Avi V; Zoghbi WA; Senior R; Klein AL; Pearlman AS
    Am J Cardiol; 2002 Nov; 90(10A):28J-34J. PubMed ID: 12450588
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Contrast echocardiography is superior to tissue harmonics for assessment of left ventricular function in mechanically ventilated patients.
    Kornbluth M; Liang DH; Brown P; Gessford E; Schnittger I
    Am Heart J; 2000 Aug; 140(2):291-6. PubMed ID: 10925345
    [TBL] [Abstract][Full Text] [Related]  

  • 50. [Contrast echocardiography: clinical applications and future prospects].
    Becher H
    Herz; 2002 May; 27(3):201-16. PubMed ID: 12096650
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Three-dimensional echocardiography: limitations of apical biplane imaging for measurement of left ventricular volume.
    Sapin PM; Schröeder KM; Gopal AS; Smith MD; King DL
    J Am Soc Echocardiogr; 1995; 8(5 Pt 1):576-84. PubMed ID: 9417199
    [TBL] [Abstract][Full Text] [Related]  

  • 52. The clinical utility of automatic boundary detection for the determination of left ventricular volume: a comparison with conventional off-line echocardiographic quantification.
    Wilson GM; Rahko PS
    J Am Soc Echocardiogr; 1995; 8(6):822-9. PubMed ID: 8611282
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Improved reliability for echocardiographic measurement of left ventricular volume using harmonic power imaging mode combined with contrast agent.
    Lafitte S; Dos Santos P; Kerouani A; Robhan T; Roudaut R
    Am J Cardiol; 2000 May; 85(10):1234-8. PubMed ID: 10802007
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Clinical utility of contrast echocardiography for quantification of left ventricular volumes and function in patients with suboptimal echocardiograms].
    Dittmann H; Razwan E; Seipel L
    Z Kardiol; 1999 Sep; 88(9):640-6. PubMed ID: 10525925
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Effect of intravenous contrast for left ventricular opacification and border definition on sensitivity and specificity of dobutamine stress echocardiography compared with coronary angiography in technically difficult patients.
    Dolan MS; Riad K; El-Shafei A; Puri S; Tamirisa K; Bierig M; St Vrain J; McKinney L; Havens E; Habermehl K; Pyatt L; Kern M; Labovitz AJ
    Am Heart J; 2001 Nov; 142(5):908-15. PubMed ID: 11685180
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Quantification of Right Ventricular Size and Function from Contrast-Enhanced Three-Dimensional Echocardiographic Images.
    Medvedofsky D; Mor-Avi V; Kruse E; Guile B; Ciszek B; Weinert L; Yamat M; Volpato V; Addetia K; Patel AR; Lang RM
    J Am Soc Echocardiogr; 2017 Dec; 30(12):1193-1202. PubMed ID: 29050828
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Realization of fully automated quantification of left ventricular volumes and systolic function using transthoracic 3D echocardiography.
    Sun L; Feng H; Ni L; Wang H; Gao D
    Cardiovasc Ultrasound; 2018 Jan; 16(1):2. PubMed ID: 29357888
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [The effect of SonoVue in endocardial border delineation and myocardial perfusion].
    Fang LG;
    Zhonghua Nei Ke Za Zhi; 2004 Nov; 43(11):824-7. PubMed ID: 15634541
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Endocardial border delineation during dobutamine infusion using contrast echocardiography.
    Mathias W; Arruda AL; Andrade JL; Filho OC; Porter TR
    Echocardiography; 2002 Feb; 19(2):109-14. PubMed ID: 11926972
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of 2 myocardial velocity gradient assessment methods during dobutamine infusion with Doppler myocardial imaging.
    Pellerin D; Berdeaux A; Cohen L; Giudicelli JF; Witchitz S; Veyrat C
    J Am Soc Echocardiogr; 1999 Jan; 12(1):22-31. PubMed ID: 9882775
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.