BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

373 related articles for article (PubMed ID: 9110276)

  • 1. NiTi shape memory alloys treated by plasma-polymerized tetrafluoroethylene. A physicochemical and electrochemical characterization.
    Yahia LH; Lombardi S; Piron D; Klemberg-Sapieha JE; Wertheimer MR
    Med Prog Technol; 1996-1997; 21(4):187-93. PubMed ID: 9110276
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating.
    Villermaux F; Tabrizian M; Yahia L; Czeremuszkin G; Piron DL
    Biomed Mater Eng; 1996; 6(4):241-54. PubMed ID: 8980833
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation.
    Chu CL; Hu T; Wu SL; Dong YS; Yin LH; Pu YP; Lin PH; Chung CY; Yeung KW; Chu PK
    Acta Biomater; 2007 Sep; 3(5):795-806. PubMed ID: 17466609
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Surface characteristics, mechanical properties, and cytocompatibility of oxygen plasma-implanted porous nickel titanium shape memory alloy.
    Wu SL; Chu PK; Liu XM; Chung CY; Ho JP; Chu CL; Tjong SC; Yeung KW; Lu WW; Cheung KM; Luk KD
    J Biomed Mater Res A; 2006 Oct; 79(1):139-46. PubMed ID: 16779766
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Corrosion resistance of a laser spot-welded joint of NiTi wire in simulated human body fluids.
    Yan XJ; Yang DZ
    J Biomed Mater Res A; 2006 Apr; 77(1):97-102. PubMed ID: 16392124
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biocorrosion investigation of two shape memory nickel based alloys: Ni-Mn-Ga and thin film NiTi.
    Stepan LL; Levi DS; Gans E; Mohanchandra KP; Ujihara M; Carman GP
    J Biomed Mater Res A; 2007 Sep; 82(3):768-76. PubMed ID: 17330873
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy.
    Chu CL; Guo C; Sheng XB; Dong YS; Lin PH; Yeung KW; Chu PK
    Acta Biomater; 2009 Jul; 5(6):2238-45. PubMed ID: 19251496
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ti-TiC-TiC/DLC gradient nano-composite film on a biomedical NiTi alloy.
    Zheng Y; Liu D; Liu X; Li L
    Biomed Mater; 2008 Dec; 3(4):044103. PubMed ID: 19029600
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.
    Wang QY; Zheng YF
    Dent Mater; 2008 Sep; 24(9):1207-11. PubMed ID: 18336899
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys.
    Yeung KW; Poon RW; Liu XY; Ho JP; Chung CY; Chu PK; Lu WW; Chan D; Cheung KM
    J Biomed Mater Res A; 2005 Nov; 75(2):256-67. PubMed ID: 16078209
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Behaviour of human endothelial cells on surface modified NiTi alloy.
    Plant SD; Grant DM; Leach L
    Biomaterials; 2005 Sep; 26(26):5359-67. PubMed ID: 15814134
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity.
    Huang HH
    J Biomed Mater Res A; 2005 Sep; 74(4):629-39. PubMed ID: 16025472
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrochemical characteristic of TiNi shape memory alloy in artificial body fluids.
    Liang C; Huang N
    J Biomed Mater Res A; 2009 Apr; 89(1):266-9. PubMed ID: 18491391
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Corrosion behaviour of a beta-titanium alloy.
    Martin E; Manceur A; Polizu S; Savadogo O; Wu MH; Yahia L
    Biomed Mater Eng; 2006; 16(3):171-82. PubMed ID: 16518016
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks' solution.
    Cissé O; Savadogo O; Wu M; Yahia L
    J Biomed Mater Res; 2002 Sep; 61(3):339-45. PubMed ID: 12115458
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Remarkable biocompatibility enhancement of porous NiTi alloys by a new surface modification approach: in-situ nitriding and in vitro and in vivo evaluation.
    Li H; Yuan B; Gao Y; Chung CY; Zhu M
    J Biomed Mater Res A; 2011 Dec; 99(4):544-53. PubMed ID: 21936044
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications.
    Oliveira NT; Guastaldi AC
    Acta Biomater; 2009 Jan; 5(1):399-405. PubMed ID: 18707926
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biocompatibility and hemocompatibility of surface-modified NiTi alloys.
    Armitage DA; Parker TL; Grant DM
    J Biomed Mater Res A; 2003 Jul; 66(1):129-37. PubMed ID: 12833439
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrochemical corrosion of titanium and titanium-based alloys.
    Kuphasuk C; Oshida Y; Andres CJ; Hovijitra ST; Barco MT; Brown DT
    J Prosthet Dent; 2001 Feb; 85(2):195-202. PubMed ID: 11208211
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.