These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 9111414)

  • 21. The biology of alternative bearing surfaces in total joint arthroplasty.
    Meneghini RM; Hallab NJ; Jacobs JJ
    Instr Course Lect; 2005; 54():481-93. PubMed ID: 15948473
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The synovial response to intraarticular injection in rats of polyethylene wear particles.
    Howie DW; Manthey B; Hay S; Vernon-Roberts B
    Clin Orthop Relat Res; 1993 Jul; (292):352-7. PubMed ID: 8519131
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Deterioration mechanisms of joint prosthesis materials. Several solutions by ion implantation surface treatments.
    Rieu J; Pichat A; Rabbe LM; Chabrol C; Robelet M
    Biomaterials; 1990 Jul; 11():51-4. PubMed ID: 2397260
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Ferrographic analysis of wear particles in arthroplastic joints.
    Mears DC; Hanley EN; Rutkowski R; Westcott VC
    J Biomed Mater Res; 1978 Nov; 12(6):867-75. PubMed ID: 739018
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of 2-methacryloyloxyethyl phosphorylcholine concentration on photo-induced graft polymerization of polyethylene in reducing the wear of orthopaedic bearing surface.
    Kyomoto M; Moro T; Miyaji F; Hashimoto M; Kawaguchi H; Takatori Y; Nakamura K; Ishihara K
    J Biomed Mater Res A; 2008 Aug; 86(2):439-47. PubMed ID: 17975818
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The roles of monocytic heat shock protein 60 and Toll-like receptors in the regional inflammation response to wear debris particles.
    Hao HN; Zheng B; Nasser S; Ren W; Latteier M; Wooley P; Morawa L
    J Biomed Mater Res A; 2010 Mar; 92(4):1373-81. PubMed ID: 19353569
    [TBL] [Abstract][Full Text] [Related]  

  • 27. On the origins of high in vivo wear rates in polyethylene components of total joint prostheses.
    Rose RM; Crugnola A; Ries M; Cimino WR; Paul I; Radin EL
    Clin Orthop Relat Res; 1979; (145):277-86. PubMed ID: 535283
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Wear in the prosthetic shoulder: association with design parameters.
    Hopkins AR; Hansen UN; Amis AA; Knight L; Taylor M; Levy O; Copeland SA
    J Biomech Eng; 2007 Apr; 129(2):223-30. PubMed ID: 17408327
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The biological reaction to polyethylene wear debris can be related with oxidation of the UHMWPE cups.
    Brach del Prever EM; Bistolfi A; Costa L; Bracco P; Linari A; Botto Micca F; Crova M; Gallinaro P
    Chir Organi Mov; 2003; 88(3):291-303. PubMed ID: 15146947
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Wear of the polyethylene components of endoprostheses following clinical application].
    Ungethüm M; Winkler-Gniewek W
    Z Orthop Ihre Grenzgeb; 1983; 121(6):683-92. PubMed ID: 6666246
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [New metod for quantification of UHMWPE wear particles around joint replacements].
    Pokorný D; Slouf M; Dybal J; Zolotarevová E; Veselý F; Jahoda D; Vavrík P; Landor I; Entlicher G; Sosna A
    Acta Chir Orthop Traumatol Cech; 2009 Oct; 76(5):374-81. PubMed ID: 19912700
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The appearances of wear on polyethylene--a comparison of in vivo and in vitro wear surfaces.
    Rostoker W
    J Biomed Mater Res; 1978 May; 12(3):317-35. PubMed ID: 670255
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Morphological characteristics of total joint arthroplasty-derived ultra-high molecular weight polyethylene (UHMWPE) wear debris that provoke inflammation in a murine model of inflammation.
    Sieving A; Wu B; Mayton L; Nasser S; Wooley PH
    J Biomed Mater Res A; 2003 Mar; 64(3):457-64. PubMed ID: 12579559
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Histological findings in soft tissues around temporomandibular joint prostheses after up to eight years of function.
    Westermark A; Leiggener C; Aagaard E; Lindskog S
    Int J Oral Maxillofac Surg; 2011 Jan; 40(1):18-25. PubMed ID: 21044827
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis.
    Nasser S; Campbell PA; Kilgus D; Kossovsky N; Amstutz HC
    Clin Orthop Relat Res; 1990 Dec; (261):171-85. PubMed ID: 2245543
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A comparison of the wear and debris generation of GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) ultra high molecular weight polyethylene.
    Endo MM; Barbour PS; Barton DC; Wroblewski BM; Fisher J; Tipper JL; Ingham E; Stone MH
    Biomed Mater Eng; 1999; 9(2):113-24. PubMed ID: 10524294
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Pathologic studies of total joint replacement.
    Bullough PG; DiCarlo EF; Hansraj KK; Neves MC
    Orthop Clin North Am; 1988 Jul; 19(3):611-25. PubMed ID: 3288937
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Distinguishing wear and creep in clinically retrieved polyethylene inserts.
    McDonald MD; Bloebaum RD
    J Biomed Mater Res; 1995 Jan; 29(1):1-7. PubMed ID: 7713947
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Long-term performance and wear of ultrahigh-molecular-weight polyethylene in total joint replacement prostheses: a brief overview and perspective.
    Gunther J; Rose RM
    J Long Term Eff Med Implants; 1994; 4(4):157-75. PubMed ID: 10155138
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties.
    Mabrey JD; Afsar-Keshmiri A; Engh GA; Sychterz CJ; Wirth MA; Rockwood CA; Agrawal CM
    J Biomed Mater Res; 2002; 63(5):475-83. PubMed ID: 12209890
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.