These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 9112207)

  • 1. In vitro evaluation of intragastric PCO2 measurement by air tonometry.
    Kolkman JJ; Zwaarekant LJ; Boshuizen K; Groeneveld AB; Meuwissen SG
    J Clin Monit; 1997 Mar; 13(2):115-9. PubMed ID: 9112207
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of air tonometric measurement of gastric regional concentrations of CO2 in critically ill septic patients.
    Heinonen PO; Jousela IT; Blomqvist KA; Olkkola KT; Takkunen OS
    Intensive Care Med; 1997 May; 23(5):524-9. PubMed ID: 9201524
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Catheter deadspace: a source of error during tonometry.
    Steverink PJ; Kolkman JJ; Groeneveld AB; de Vries JW
    Br J Anaesth; 1998 Mar; 80(3):337-41. PubMed ID: 9623434
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of air as an equilibration medium in gastric tonometry: an in vitro evaluation of two techniques for measuring air PCO2.
    Venkatesh B; Morgan J; Jones RD; Clague A
    Anaesth Intensive Care; 1998 Feb; 26(1):46-50. PubMed ID: 9513667
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Factors affecting performance of air tonometry using the TONOCAP.
    Dullenkopf A; Cornelius A; Gerber AC; Weiss M
    Anaesth Intensive Care; 2002 Dec; 30(6):794-9. PubMed ID: 12500520
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intraluminal "balloonless" air tonometry: a new method for determination of gastrointestinal mucosal carbon dioxide tension.
    Salzman AL; Strong KE; Wang H; Wollert PS; Vandermeer TJ; Fink MP
    Crit Care Med; 1994 Jan; 22(1):126-34. PubMed ID: 8124955
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of gastric air tonometry with standard saline tonometry.
    Tzelepis G; Kadas V; Michalopoulos A; Geroulanos S
    Intensive Care Med; 1996 Nov; 22(11):1239-43. PubMed ID: 9120119
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of hypothermia on calculated values using saline and automated air tonometry.
    Chapman MV; Woolf RL; Bennett-Guerrero E; Mythen MG
    J Cardiothorac Vasc Anesth; 2002 Jun; 16(3):304-7. PubMed ID: 12073201
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monitoring gastric mucosal carbon dioxide pressure using gas tonometry: in vitro and in vivo validation studies.
    Creteur J; De Backer D; Vincent JL
    Anesthesiology; 1997 Sep; 87(3):504-10. PubMed ID: 9316953
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gastric tonometry: precision and reliability are improved by a phosphate buffered solution.
    Knichwitz G; Kuhmann M; Brodner G; Mertes N; Goeters C; Brüssel T
    Crit Care Med; 1996 Mar; 24(3):512-6. PubMed ID: 8625643
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of air tonometry with gastric tonometry using saline and other equilibrating fluids: an in vivo and in vitro study.
    Barry B; Mallick A; Hartley G; Bodenham A; Vucevic M
    Intensive Care Med; 1998 Aug; 24(8):777-84. PubMed ID: 9757920
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro validation of gastric air tonometry using perfluorocarbon FC 43 and 0.9% sodium chloride.
    Graf J; Königs B; Mottaghy K; Janssens U
    Br J Anaesth; 2000 Apr; 84(4):497-9. PubMed ID: 10823103
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new method for continuous tonometric pCO2 measurement--in vitro studies.
    Fröjse R; Arnerlöv C; Hedberg B; Haggström M; Bäcklund T; Lindahl O; Angquist KA
    Physiol Meas; 1999 May; 20(2):129-36. PubMed ID: 10390015
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous fiberoptic PCO2 monitoring indicates poorer gastric perfusion during supraceliac aortic clamping than conventional gastric tonometry in humans: a pilot study.
    Melton A
    J Cardiothorac Vasc Anesth; 2000 Dec; 14(6):666-71. PubMed ID: 11139106
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous assessment of gastric intramucosal PCO2 and pH in hemorrhagic shock using capnometric recirculating gas tonometry.
    Guzman JA; Kruse JA
    Crit Care Med; 1997 Mar; 25(3):533-7. PubMed ID: 9118673
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Advantage of buffered solutions or automated capnometry in air-filled balloons for use in gastric tonometry.
    Temmesfeld-Wollbrück B; Szalay A; Olschewski H; Grimminger F; Seeger W
    Intensive Care Med; 1997 Apr; 23(4):423-7. PubMed ID: 9142582
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characteristics of time-dependent PCO2 tonometry in the normal human stomach.
    Kolkman JJ; Steverink PJ; Groeneveld AB; Meuwissen SG
    Br J Anaesth; 1998 Nov; 81(5):669-75. PubMed ID: 10193274
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the 5-French saline paediatric gastric tonometer.
    Thorburn K; Hatherill M; Roberts PC; Durward A; Tibby SM; Murdoch IA
    Intensive Care Med; 2000 Jul; 26(7):973-80. PubMed ID: 10990115
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [PCO2 tonometry of the stomach].
    Otte JA; Kolkman JJ; Groeneveld AB
    Ned Tijdschr Geneeskd; 2000 Dec; 144(49):2341-5. PubMed ID: 11129968
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of oesophageal and gastric air tonometry in patients with circulatory failure.
    Janssens U; Groesdonk H; Graf J; Radke PW; Lepper W; Hanrath P
    Br J Anaesth; 2002 Aug; 89(2):237-41. PubMed ID: 12378659
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.