These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 9114788)

  • 1. Usefulness of transesophageal echocardiography in detecting changes in flow dynamics responsible for malperfusion phenomena observed during surgery of aortic dissection.
    Yamada E; Matsumura M; Kimura S; Kyo S; Ueda K; Yokote Y; Omoto R
    Am J Cardiol; 1997 Apr; 79(8):1149-52. PubMed ID: 9114788
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnosis and management of cerebral malperfusion phenomena during aortic dissection repair by transesophageal Doppler echocardiographic monitoring.
    Coletti G; Torracca L; La Canna G; Maisano F; Sebastiano P; Fucci C; Berra P; Alfieri O
    J Card Surg; 1996; 11(5):355-8. PubMed ID: 8969381
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intraoperative echocardiography for diagnosis and treatment of aortic dissection. Utility of color flow mapping for surgical decision making in acute stage.
    Kyo S; Takamoto S; Omoto R; Matsumura M; Kimura S; Neya K; Adachi H; Yokote Y
    Herz; 1992 Dec; 17(6):377-89. PubMed ID: 1483626
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Usefulness of ultrasound in the management of aortic dissection.
    Liu F; Huang L
    Rev Cardiovasc Med; 2018 Sep; 19(3):103-109. PubMed ID: 31054559
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transoesophageal echocardiographic follow-up of patients with surgically treated aortic aneurysms.
    Simon P; Owen AN; Moidl R; Kupilik N; Grabenwoeger M; Anwari A; Mohl W; Wolner E; Havel M
    Eur Heart J; 1995 Mar; 16(3):402-5. PubMed ID: 7789384
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Usefulness of Transesophageal Echocardiography in Guiding Acute Aortic Dissection Management During Open Repair of an Abdominal Aortic Aneurysm.
    Kainuma A; Ihara M; Miyawaki I; Mima H; Koyama T; Yamazaki K
    J Cardiothorac Vasc Anesth; 2016 Jun; 30(3):725-8. PubMed ID: 26520024
    [No Abstract]   [Full Text] [Related]  

  • 7. Detection and monitoring of complications associated with femoral or axillary arterial cannulation for surgical repair of aortic dissection.
    Orihashi K; Sueda T; Okada K; Imai K
    J Cardiothorac Vasc Anesth; 2006 Feb; 20(1):20-5. PubMed ID: 16458208
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Newly developed aortic dissection in the abdominal aorta after femoral arterial perfusion.
    Orihashi K; Sueda T; Okada K; Imai K
    Ann Thorac Surg; 2005 Jun; 79(6):1945-9. PubMed ID: 15919289
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Intraoperative evaluation of visceral arteries by transesophageal echocardiography during aortic fenestration].
    Yoshimura M; Kurosawa A; Kunisawa T; Kanda H; Takahata O; Iwasaki H
    Masui; 2013 Oct; 62(10):1194-8. PubMed ID: 24228454
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Management of intraoperative malperfusion syndrome using femoral artery cannulation for repair of acute type A aortic dissection.
    Shimokawa T; Takanashi S; Ozawa N; Itoh T
    Ann Thorac Surg; 2008 May; 85(5):1619-24. PubMed ID: 18442550
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transesophageal echocardiographic evaluation of an intraoperative retrograde acute aortic dissection: case report.
    Culp WC; Morgan-Vanderlick KJ; Reiter CG
    Cardiovasc Ultrasound; 2006 Apr; 4():19. PubMed ID: 16584559
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Emergency surgical management of acute aortic dissection: role of transesophageal echocardiography.
    Mastrogiovanni G; Masiello P; Leone R; Iesu S; Di Benedetto G
    G Ital Cardiol; 1999 Oct; 29(10):1137-41. PubMed ID: 10546123
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transesophageal Doppler echocardiographic monitoring for malperfusion during aortic dissection repair.
    Neustein SM; Lansman SL; Quintana CS; Suriani R; Ergin A; Griepp RB
    Ann Thorac Surg; 1993 Aug; 56(2):358-61. PubMed ID: 8347022
    [No Abstract]   [Full Text] [Related]  

  • 14. Aortic arch cannulation with the guidance of transesophageal echocardiography for Stanford type A aortic dissection.
    Ma H; Xiao Z; Shi J; Liu L; Qin C; Guo Y
    J Cardiothorac Surg; 2018 Oct; 13(1):106. PubMed ID: 30309362
    [TBL] [Abstract][Full Text] [Related]  

  • 15. How to guide stent-graft implantation in type B aortic dissection? Comparison of angiography, transesophageal echocardiography, and intravascular ultrasound.
    Koschyk DH; Nienaber CA; Knap M; Hofmann T; Kodolitsch YV; Skriabina V; Ismail M; Franzen O; Rehders TC; Dieckmann C; Lund G; Reichenspurner H; Meinertz T
    Circulation; 2005 Aug; 112(9 Suppl):I260-4. PubMed ID: 16159828
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Utility of transesophageal echocardiography in the diagnosis of disease of the thoracic aorta.
    Wiet SP; Pearce WH; McCarthy WJ; Joob AW; Yao JS; McPherson DD
    J Vasc Surg; 1994 Oct; 20(4):613-20. PubMed ID: 7933263
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Aortic dissection after cardiopulmonary bypass detected by intraoperative transesophageal echocardiography.
    Andersen C; Joyce FS; Tingleff J; Arendrup H
    Acta Anaesthesiol Scand; 1997 Oct; 41(9):1227-8. PubMed ID: 9366951
    [No Abstract]   [Full Text] [Related]  

  • 18. Transesophageal echocardiographic Doppler findings in patients with penetrating aortic ulcers.
    Atar S; Nagai T; Birnbaum Y; Harold JG; Luo H; Naqvi TZ; Siegel RJ
    Am J Cardiol; 1999 Jan; 83(1):133-5, A10. PubMed ID: 10073804
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Diagnostic accuracy of transesophageal echocardiography in the diagnosis of aortic dissection: comparison with computerized axial tomography].
    Nicosia A; Greco G; Felis S; Drago A; Deste W; Tamburino C; Calvi V; Monaca V; Abbate M; Giuffrida G
    Cardiologia; 1995 May; 40(5):329-39. PubMed ID: 8529244
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transesophageal echocardiography-guided algorithm for stent-graft implantation in aortic dissection.
    Rocchi G; Lofiego C; Biagini E; Piva T; Bracchetti G; Lovato L; Parlapiano M; Ferlito M; Rapezzi C; Branzi A; Fattori R
    J Vasc Surg; 2004 Nov; 40(5):880-5. PubMed ID: 15557900
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.