These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 9122054)

  • 21. Large femoral bone loss after hip revision using the uncemented proximally porous-coated Bi-Metric prosthesis: 22 hips followed for a mean of 6 years.
    Adolphson PY; Salemyr MO; Sköldenberg OG; Bodén HS
    Acta Orthop; 2009 Feb; 80(1):14-9. PubMed ID: 19234883
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty.
    Bobyn JD; Glassman AH; Goto H; Krygier JJ; Miller JE; Brooks CE
    Clin Orthop Relat Res; 1990 Dec; (261):196-213. PubMed ID: 2245546
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Loosening and bone resorption in exeter hip arthroplasties. Review at a minimum of five years.
    Rockborn P; Olsson SS
    J Bone Joint Surg Br; 1993 Nov; 75(6):865-8. PubMed ID: 8245072
    [TBL] [Abstract][Full Text] [Related]  

  • 24. An experimental animal model of aseptic loosening of hip prostheses in sheep to study early biochemical changes at the interface membrane.
    El-Warrak AO; Olmstead M; Schneider R; Meinel L; Bettschart-Wolfisberger R; Akens MK; Auer J; von Rechenberg B
    BMC Musculoskelet Disord; 2004 Mar; 5():7. PubMed ID: 15113432
    [TBL] [Abstract][Full Text] [Related]  

  • 25. New femoral designs: do they influence stress shielding?
    Glassman AH; Bobyn JD; Tanzer M
    Clin Orthop Relat Res; 2006 Dec; 453():64-74. PubMed ID: 17312586
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of the painful total hip arthroplasty.
    Fisher DA
    Semin Arthroplasty; 1992 Oct; 3(4):229-38. PubMed ID: 10147932
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [The importance of roentgenological and scintigraphic studies in patients with and without thigh pain following cementless PCA hip endoprosthesis].
    Pohlemann T; Steinmetz M; Ehrenheim C; Hundeshagen H; Tscherne H
    Z Orthop Ihre Grenzgeb; 1995; 133(1):25-33. PubMed ID: 7886996
    [TBL] [Abstract][Full Text] [Related]  

  • 28. 100 cemented versus 100 noncemented stems with comparison of 25 matched pairs.
    D'Lima DD; Oishi CS; Petersilge WJ; Colwell CW; Walker RH
    Clin Orthop Relat Res; 1998 Mar; (348):140-8. PubMed ID: 9553546
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of mechanical stress and change in bone mineral density between two types of femoral implant using finite element analysis.
    Hirata Y; Inaba Y; Kobayashi N; Ike H; Fujimaki H; Saito T
    J Arthroplasty; 2013 Dec; 28(10):1731-5. PubMed ID: 23683518
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The predictive value of stress shielding for quantification of adaptive bone resorption around hip replacements.
    Kuiper JH; Huiskes R
    J Biomech Eng; 1997 Aug; 119(3):228-31. PubMed ID: 9285333
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The course of radiographic loosening, pain and functional outcome around the first revision of a total hip arthroplasty.
    Aghayev E; Teuscher R; Neukamp M; Lee EJ; Melloh M; Eggli S; Röder C
    BMC Musculoskelet Disord; 2013 May; 14():167. PubMed ID: 23672339
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.
    Nam D; Barrack T; Johnson SR; Nunley RM; Barrack RL
    Clin Orthop Relat Res; 2016 Oct; 474(10):2115-22. PubMed ID: 26911973
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The 21- to 27-year results of the Harris-Galante cementless total hip arthroplasty.
    Kawamura H; Mishima H; Sugaya H; Nishino T; Shimizu Y; Miyakawa S
    J Orthop Sci; 2016 May; 21(3):342-7. PubMed ID: 26970833
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Fracture of a spline of the femoral stem in an ingrown modular hip implant.
    McNabb DC; Jennings JM; Dennis DA
    Hip Int; 2016 Jul; 26(4):e35-8. PubMed ID: 27443223
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cellular reactions in hip prosthesis loosening.
    Pizzoferrato A; Stea S; Ciapetti G; Cenni E; Tarabusi C; Toni A
    Chir Organi Mov; 1992; 77(4):337-48. PubMed ID: 1297568
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Cement-free hip endoprosthesis: PCA shaft prosthesis, 5-7-year results].
    Hösli P
    Z Orthop Ihre Grenzgeb; 1993; 131(6):518-23. PubMed ID: 8310740
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Thigh pain after cementless hip arthroplasty. Annoyance or ill omen.
    Campbell AC; Rorabeck CH; Bourne RB; Chess D; Nott L
    J Bone Joint Surg Br; 1992 Jan; 74(1):63-6. PubMed ID: 1732268
    [TBL] [Abstract][Full Text] [Related]  

  • 38. No Benefit After THA Performed With Computer-assisted Cup Placement: 10-year Results of a Randomized Controlled Study.
    Parratte S; Ollivier M; Lunebourg A; Flecher X; Argenson JN
    Clin Orthop Relat Res; 2016 Oct; 474(10):2085-93. PubMed ID: 27150344
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pain in the thigh following total hip replacement with a porous-coated anatomic prosthesis for osteoarthrosis. A five-year follow-up study.
    Bourne RB; Rorabeck CH; Ghazal ME; Lee MH
    J Bone Joint Surg Am; 1994 Oct; 76(10):1464-70. PubMed ID: 7929493
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty.
    Bobyn JD; Mortimer ES; Glassman AH; Engh CA; Miller JE; Brooks CE
    Clin Orthop Relat Res; 1992 Jan; (274):79-96. PubMed ID: 1729025
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.