These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 9124665)

  • 21. Pre-hospital use of the SCOTI device.
    Lockey D
    Anaesthesia; 1997 Feb; 52(2):190. PubMed ID: 9059129
    [No Abstract]   [Full Text] [Related]  

  • 22. Portable devices used to detect endotracheal intubation during emergency situations: a review.
    Cardoso MM; Banner MJ; Melker RJ; Bjoraker DG
    Crit Care Med; 1998 May; 26(5):957-64. PubMed ID: 9590328
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Survey of use of end-tidal carbon dioxide for confirming tracheal tube placement in intensive care units in the UK.
    Kannan S; Manji M
    Anaesthesia; 2003 May; 58(5):476-9. PubMed ID: 12751507
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Confirming tracheal intubation.
    Varley J
    Anaesthesia; 2007 May; 62(5):530; author reply 530. PubMed ID: 17448074
    [No Abstract]   [Full Text] [Related]  

  • 25. Validation of the new intubation detector device: a manikin study.
    Umesh G; Jasvinder K; Tim TJ
    J Clin Monit Comput; 2012 Dec; 26(6):423-7. PubMed ID: 22581039
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Colorimetric end-tidal carbon dioxide monitoring for tracheal intubation.
    Goldberg JS; Rawle PR; Zehnder JL; Sladen RN
    Anesth Analg; 1990 Feb; 70(2):191-4. PubMed ID: 2105671
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Clinical tests for confirming tracheal intubation or excluding oesophageal intubation: a diagnostic test accuracy systematic review and meta-analysis.
    Hansel J; Law JA; Chrimes N; Higgs A; Cook TM
    Anaesthesia; 2023 Aug; 78(8):1020-1030. PubMed ID: 37325847
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The esophageal detector device. Does it work?
    Zaleski L; Abello D; Gold MI
    Anesthesiology; 1993 Aug; 79(2):244-7. PubMed ID: 8342836
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The tracheal detecting-bulb: a new device to distinguish tracheal from esophageal intubation.
    Tong YL; Sun M; Tang WH; Xia JY
    Acta Anaesthesiol Sin; 2002 Dec; 40(4):159-63. PubMed ID: 12596613
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Aspirated air capnography with esophageal detector device to confirm tracheal intubation in rapid sequence induction.
    Ghabash M; Choueiry P; Matta M
    Middle East J Anaesthesiol; 1998 Jun; 14(5):381-6. PubMed ID: 9785341
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The Fenem CO2 detector device. An apparatus to prevent unnoticed oesophageal intubation.
    Denman WT; Hayes M; Higgins D; Wilkinson DJ
    Anaesthesia; 1990 Jun; 45(6):465-7. PubMed ID: 2116738
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Towards evidence based emergency medicine: best BETs from the Manchester Royal Infirmary. Colourimetric CO(2) detector compared with capnography for confirming ET tube placement.
    Hogg K; Teece S
    Emerg Med J; 2003 May; 20(3):265-6. PubMed ID: 12748149
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation.
    Li J
    J Emerg Med; 2001 Apr; 20(3):223-9. PubMed ID: 11267809
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Rapid detection of oesophageal intubation: take care when using colorimetric capnometry.
    Puntervoll SA; Søreide E; Jacewicz W; Bjelland E
    Acta Anaesthesiol Scand; 2002 Apr; 46(4):455-7. PubMed ID: 11952450
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The lost tracheal tube: a rare complication of failed intubation.
    Jöhr M; Schubiger C
    Paediatr Anaesth; 1995; 5(6):397-8. PubMed ID: 8597979
    [No Abstract]   [Full Text] [Related]  

  • 36. Evaluation of an electronic esophageal detector device in patients with morbid obesity and pulmonary failure.
    Wolfe TR; Kimball EJ; Ogden LL; Schafer P; Hartsell SC; Richardson S; Moog MR; Barton R
    Prehosp Emerg Care; 2002; 6(1):59-64. PubMed ID: 11789652
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Detection and correction of accidental oesophageal intubation during flexible lightwand-guided intubation via the intubating laryngeal mask.
    Dimitriou V; Voyagis GS; Brimacombe J
    Anaesth Intensive Care; 2002 Feb; 30(1):52-4. PubMed ID: 11939441
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The oesophageal detector device. An assessment of accuracy and ease of use by paramedics.
    Donahue PL
    Anaesthesia; 1994 Oct; 49(10):863-5. PubMed ID: 7802180
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Does end-tidal capnography confirm tracheal intubation in fresh-frozen cadavers?
    Reid C; Ferguson I; Burns B; Habig K; Shareef M
    Emerg Med J; 2017 May; 34(5):315-317. PubMed ID: 27663507
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Capnography during fibreoptic intubation.
    Asai T; Murao K; Shingu K
    Anaesthesia; 2003 Nov; 58(11):1131. PubMed ID: 14616615
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.