These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
120 related articles for article (PubMed ID: 9124942)
1. Technique of right heart protection and deairing during heartmate vented electric LVAD implantation. Van Meter CH; Robbins RJ; Ochsner JL Ann Thorac Surg; 1997 Apr; 63(4):1191-2. PubMed ID: 9124942 [TBL] [Abstract][Full Text] [Related]
2. Immediate post-LVAD implant support: two approaches. Syracuse PL; Yager C; Smedira N; Savage RM J Extra Corpor Technol; 2005 Dec; 37(4):373-6. PubMed ID: 16524155 [TBL] [Abstract][Full Text] [Related]
3. Transition from cardiopulmonary bypass to the HeartMate left ventricular assist device. Tector AJ; Kress DC; Downey FX; Schmahl TM; Dasse KA; Poirier VL Ann Thorac Surg; 1998 Mar; 65(3):643-6. PubMed ID: 9527188 [TBL] [Abstract][Full Text] [Related]
4. Can Perioperative Right Ventricular Support Prevent Postoperative Right Heart Failure in Patients With Biventricular Dysfunction Undergoing Left Ventricular Assist Device Implantation? Deschka H; Holthaus AJ; Sindermann JR; Welp H; Schlarb D; Monsefi N; Martens S; Scherer M J Cardiothorac Vasc Anesth; 2016 Jun; 30(3):619-26. PubMed ID: 27321789 [TBL] [Abstract][Full Text] [Related]
5. Management of the in situ HeartMate II left ventricular assist device during non-transplant, non-exchange cardiac reoperations. Balsam LB; Reyentovich A; Son AY; DeAnda A Perfusion; 2016 Sep; 31(6):465-70. PubMed ID: 26701904 [TBL] [Abstract][Full Text] [Related]
6. Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices. Patel ND; Weiss ES; Schaffer J; Ullrich SL; Rivard DC; Shah AS; Russell SD; Conte JV Ann Thorac Surg; 2008 Sep; 86(3):832-40; discussion 832-40. PubMed ID: 18721570 [TBL] [Abstract][Full Text] [Related]
7. Technique for less invasive implantation of Heartmate II left ventricular assist device without median sternotomy. Anyanwu AC Semin Thorac Cardiovasc Surg; 2011; 23(3):241-4. PubMed ID: 22172362 [TBL] [Abstract][Full Text] [Related]
8. Mechanical circulatory support for the right ventricle in the setting of a left ventricular assist device. Steffen RJ; Halbreiner MS; Zhang L; Fukamachi K; Soltesz EG; Starling RC; Moazami N Expert Rev Med Devices; 2014 Nov; 11(6):587-93. PubMed ID: 25019691 [TBL] [Abstract][Full Text] [Related]
9. Implantable left ventricular assist device. Approaching an alternative for end-stage heart failure. Implantable LVAD Study Group. McCarthy PM; James KB; Savage RM; Vargo R; Kendall K; Harasaki H; Hobbs RE; Pashkow FJ Circulation; 1994 Nov; 90(5 Pt 2):II83-6. PubMed ID: 7955290 [TBL] [Abstract][Full Text] [Related]
10. HeartMate vented-electric left ventricular assist system: technique for intrathoracic or intraperitoneal implantation via a left thoracotomy. Gregoric I; Wadia Y; Radovancevic B; Messner G; Khan T; Frazier OH J Heart Lung Transplant; 2004 Jun; 23(6):759-62. PubMed ID: 15366437 [TBL] [Abstract][Full Text] [Related]
11. Use of left ventricular assist device (HeartMate II): a Singapore experience. Lim CP; Sivathasan C; Tan TE; Lim CH; Kerk KL; Sim DK Artif Organs; 2014 Jul; 38(7):543-8. PubMed ID: 24392937 [TBL] [Abstract][Full Text] [Related]
16. Longitudinal change in quality of life and impact on survival after left ventricular assist device implantation. Grady KL; Meyer PM; Dressler D; Mattea A; Chillcott S; Loo A; White-Williams C; Todd B; Ormaza S; Kaan A; Costanzo MR; Piccione W Ann Thorac Surg; 2004 Apr; 77(4):1321-7. PubMed ID: 15063260 [TBL] [Abstract][Full Text] [Related]
17. Does CircuLite Synergy assist device as partial ventricular support have a place in modern management of advanced heart failure? Mohite PN; Sabashnikov A; Simon AR; Weymann A; Patil NP; Unsoeld B; Bireta C; Popov AF Expert Rev Med Devices; 2015 Jan; 12(1):49-60. PubMed ID: 25454250 [TBL] [Abstract][Full Text] [Related]
18. HeartMate 3 left ventricular assist device minimally invasive off-pump implantation. Attisani M; Centofanti P; Baronetto A; Lodo V; Boffini M; Rinaldi M; Barbero C Multimed Man Cardiothorac Surg; 2018 Dec; 2018():. PubMed ID: 30549510 [TBL] [Abstract][Full Text] [Related]
19. Right Ventricular Failure Post LVAD Implantation Corrected with Biventricular Support: An In Vitro Model. Shehab S; Allida SM; Davidson PM; Newton PJ; Robson D; Jansz PC; Hayward CS ASAIO J; 2017; 63(1):41-47. PubMed ID: 28033201 [TBL] [Abstract][Full Text] [Related]
20. Permanent mechanical circulatory support with an implantable left ventricular assist device. McCarthy PM; Young JB; Smedira NG; Hobbs RE; Vargo RL; Starling RC Ann Thorac Surg; 1997 May; 63(5):1458-61. PubMed ID: 9146345 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]