BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 9130116)

  • 1. Wear patterns in the Sorin Bicarbon mechanical heart valve: a clinical explant study.
    Hasenkam JM; Pasquino E; Stacchino C; Arru P; Vallana F; Paulsen PK
    J Heart Valve Dis; 1997 Mar; 6(2):105-14. PubMed ID: 9130116
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of valve-related complications in patients with Sorin Bicarbon prosthesis: a seven-year experience.
    Bortolotti U; Milano A; D'Alfonso A; Piccin C; Mecozzi G; Magagna P; Fabbri A; Mazzucco A
    J Heart Valve Dis; 2001 Nov; 10(6):795-801. PubMed ID: 11767189
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Late incidence and determinants of reoperation in patients with prosthetic heart valves.
    Ruel M; Kulik A; Rubens FD; Bédard P; Masters RG; Pipe AL; Mesana TG
    Eur J Cardiothorac Surg; 2004 Mar; 25(3):364-70. PubMed ID: 15019662
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In-vitro assessment of the wear development mechanism and stabilization of wear in the Edwards MIRA/Sorin Bicarbon mechanical heart valve orifice ring.
    Reul H; Schmitz C; Pfaff EM; Hohlstein C; Schmidt PA; Rau G; Arru P
    J Heart Valve Dis; 2002 May; 11(3):409-18; discussion 418. PubMed ID: 12056736
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Bicarbon heart valve prosthesis: short-term results.
    Casselman F; Herijgers P; Meyns B; Flameng W; Daenen W
    J Heart Valve Dis; 1997 Jul; 6(4):410-5. PubMed ID: 9263874
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Midterm evaluation of the Sorin Bicarbon heart valve prosthesis: single-center experience.
    Vitale N; Cappabianca G; Visicchio G; Fondacone C; Paradiso V; Mannatrizio G; Schinosa Lde L
    Ann Thorac Surg; 2004 Feb; 77(2):527-31. PubMed ID: 14759432
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pitfalls and outcomes from accelerated wear testing of mechanical heart valves.
    Campbell A; Baldwin T; Peterson G; Bryant J; Ryder K
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S124-32; discussion 144-8. PubMed ID: 8803765
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Morphologic findings in explanted Hancock II porcine bioprostheses.
    Butany J; Yu W; Silver MD; David TE
    J Heart Valve Dis; 1999 Jan; 8(1):4-15. PubMed ID: 10096476
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A single-center experience of the Sorin Bicarbon heart valve prosthesis: long-term clinical, hematological and hemodynamic results.
    Whitaker DC; James SE; Walesby RK
    J Heart Valve Dis; 2004 Jan; 13(1):97-102. PubMed ID: 14765847
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biological versus mechanical aortic prosthesis? A nineteen-year comparison in a propensity-matched population.
    Bottio T; Rizzoli G; Caprili L; Testolin L; Thiene G; Gerosa G
    J Heart Valve Dis; 2005 Jul; 14(4):493-500. PubMed ID: 16116876
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Indication of cavitation in mechanical heart valve patients.
    Andersen TS; Johansen P; Paulsen PK; Nygaard H; Hasenkam JM
    J Heart Valve Dis; 2003 Nov; 12(6):790-6. PubMed ID: 14658822
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Valve replacement with bileaflet HP-Biplus mechanical prostheses versus standard prostheses: long-term results.
    Cianciulli TF; Lax JA; Beck MA; Guidoin R; Saccheri MC; Cosarinsky LA; Gadea FJ; Dorelle AN; Prezioso HA; Vidal LA
    J Heart Valve Dis; 2008 Mar; 17(2):206-15. PubMed ID: 18512493
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves.
    Ruel M; Rubens FD; Masters RG; Pipe AL; Bédard P; Hendry PJ; Lam BK; Burwash IG; Goldstein WG; Brais MP; Keon WJ; Mesana TG
    J Thorac Cardiovasc Surg; 2004 Jan; 127(1):149-59. PubMed ID: 14752425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Choice of replacement valve in the elderly.
    Kobayashi Y; Eishi K; Nagata S; Nakano K; Sasako Y; Kobayashi J; Kosakai Y; Miyatake K
    J Heart Valve Dis; 1997 Jul; 6(4):404-9. PubMed ID: 9263873
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ten-year outcome with the sorin bicarbon and Baxter Mira bileaflet prostheses in the aortic position.
    Vitale N; de Feo M; Renzulli A; Gregorio R; Cappabianca G; Onorati F; de Luca L; Schinosa T; Cotrufo M
    J Heart Valve Dis; 2004 Jul; 13(4):632-7. PubMed ID: 15311871
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Porcine aortic vs. bovine pericardial valves: a morphologic study of the Xenomedica and Mitroflow bioprostheses.
    Goffin YA; Bartik MA; Hilbert SL
    Z Kardiol; 1986; 75 Suppl 2():213-22. PubMed ID: 3727689
    [No Abstract]   [Full Text] [Related]  

  • 17. Seven-year results with the St Jude Medical Silzone mechanical prosthesis.
    Jamieson WR; Fradet GJ; Abel JG; Janusz MT; Lichtenstein SV; MacNab JS; Stanford EA; Chan F
    J Thorac Cardiovasc Surg; 2009 May; 137(5):1109-15.e2. PubMed ID: 19379975
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surface and edge wear of Björk-Shiley Delrin heart valve discs.
    Engel PA; Clark ES; Park SH; McKellop H; Thyagarajan K; Zhao Z; Campbell P; Wieting DW
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S190-205. PubMed ID: 8905520
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ex-vivo characterization of three Björk-Shiley Delrin heart valves.
    Farè S; Brunella MF; Bruschi G; Vitali E
    J Heart Valve Dis; 2008 May; 17(3):325-31. PubMed ID: 18592930
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Wear assessment in bileaflet heart valves.
    Arru P; Rinaldi S; Stacchino C; Vallana F
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S133-43; discussion 144-8. PubMed ID: 8803766
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.