These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 9135344)

  • 1. A study of mixing conditions during nitric oxide administration using simultaneous fast response chemiluminescence and capnography.
    Foubert L; Mareels K; Fredholm M; Lundin S; Stenqvist O
    Br J Anaesth; 1997 Apr; 78(4):436-8. PubMed ID: 9135344
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Variation of nitric oxide concentration during inspiration.
    Sydow M; Bristow F; Zinserling J; Allen SJ
    Crit Care Med; 1997 Feb; 25(2):365-71. PubMed ID: 9034278
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A delivery system for inhalation of nitric oxide evaluated with chemiluminescence, electrochemical fuel cells, and capnography.
    Lindberg L; Rydgren G; Larsson A; Olsson SG; Nordström L
    Crit Care Med; 1997 Jan; 25(1):190-6. PubMed ID: 8989197
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nitric oxide administration after the ventilator: evaluation of mixing conditions.
    Westfelt UN; Lundin S; Stenqvist O
    Acta Anaesthesiol Scand; 1997 Feb; 41(2):266-73. PubMed ID: 9062612
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Inaccuracies of nitric oxide delivery systems during adult mechanical ventilation.
    Imanaka H; Hess D; Kirmse M; Bigatello LM; Kacmarek RM; Steudel W; Hurford WE
    Anesthesiology; 1997 Mar; 86(3):676-88. PubMed ID: 9066335
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Production of nitrogen dioxide during nitric oxide therapy using the Servo Ventilator 300 during volume-controlled ventilation.
    Lindberg L; Rydgren G
    Acta Anaesthesiol Scand; 1999 Mar; 43(3):289-94. PubMed ID: 10081534
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Delivery of inhaled nitric oxide using the Ohmeda INOvent Delivery System.
    Kirmse M; Hess D; Fujino Y; Kacmarek RM; Hurford WE
    Chest; 1998 Jun; 113(6):1650-7. PubMed ID: 9631807
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Distribution of inhaled nitric oxide during sequential and continuous administration into the inspiratory limb of the ventilator.
    Mourgeon E; Gallart L; Rao GS; Lu Q; Law-Koune JD; Puybasset L; Coriat P; Rouby JJ
    Intensive Care Med; 1997 Aug; 23(8):849-58. PubMed ID: 9310802
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of proportional and continuous nitric oxide delivery systems during pressure- and volume-controlled ventilation.
    Hiesmayr MJ; Neugebauer T; Lassnigg A; Steltzer H; Haider W; Gilly H
    Br J Anaesth; 1998 Oct; 81(4):544-52. PubMed ID: 9924230
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flow-proportional administration of nitric oxide with a new delivery system: inspiratory nitric oxide concentration fluctuation during different flow conditions.
    Sydow M; Bristow F; Zinserling J; Allen SJ
    Chest; 1997 Aug; 112(2):496-504. PubMed ID: 9266890
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nitric oxide administration using constant-flow ventilation.
    Skimming JW; Cassin S; Blanch PB
    Chest; 1995 Oct; 108(4):1065-72. PubMed ID: 7555121
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Evaluation of a new nitric oxide delivery system during mechanical ventilation].
    Noguchi T; Miyakawa H; Mori M; Kitano T; Iwasaka H; Oda S; Taniguchi K; Honda N
    Masui; 1994 Jul; 43(7):1083-6. PubMed ID: 7933483
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nitrogen dioxide reducing ascorbic acid technologies in the ventilator circuit leads to uniform NO concentration during inspiration.
    Pezone MJ; Wakim MG; Denton RJ; Gamero LG; Roscigno RF; Gilbert RJ; Lovich MA
    Nitric Oxide; 2016 Aug; 58():42-50. PubMed ID: 27264784
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Variation of inhaled nitric oxide concentration with the use of a continuous flow ventilator.
    De Jaegere AP; Jacobs FI; Laheij NG; van den Anker JN
    Crit Care Med; 1997 Jun; 25(6):995-1002. PubMed ID: 9201053
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Laboratory evaluation of the I-NOvent nitric oxide delivery device.
    Young JD; Roberts M; Gale LB
    Br J Anaesth; 1997 Sep; 79(3):398-401. PubMed ID: 9389867
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Formation of nitrogen dioxide from nitric oxide and their measurement in clinically relevant circumstances.
    Schedin U; Frostell CG; Gustafsson LE
    Br J Anaesth; 1999 Feb; 82(2):182-92. PubMed ID: 10364991
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nitric oxide delivery to the lung: a model.
    Jones PR; Hooper RH; Stopp N; Moore NA
    Eur J Anaesthesiol; 2000 Mar; 17(3):160-7. PubMed ID: 10758464
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Nitric oxide (NO) measurement accuracy.
    Nishimura M; Imanaka H; Uchiyama A; Tashiro C; Hess D; Kacmarek RM
    J Clin Monit; 1997 Jul; 13(4):241-8. PubMed ID: 9269618
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of nitric oxide predilution on inhaled nitrogen dioxide concentrations.
    Foubert L; Mareels K; den Blauwen N; Herregods L; Rolly G
    Anaesthesia; 1999 Mar; 54(3):220-5. PubMed ID: 10364856
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Inhaled nitric monoxide. Application and continuous measurement of concentration].
    Benzing A; Beyer U; Kiefer P; Geiger K
    Anaesthesist; 1993 Mar; 42(3):175-8. PubMed ID: 8480905
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.